Hybrid FES-robot cooperative control of ambulatory gait rehabilitation exoskeleton
Open accessThe DOI matches its Crossref record; 48 of the 48 references it cites were found in a registry or an index.
Abstract
Robotic and functional electrical stimulation (FES) approaches are used for rehabilitation of walking impairment of spinal cord injured individuals. Although devices are commercially available, there are still issues that remain to be solved. Control of hybrid exoskeletons aims at blending robotic exoskeletons and electrical stimulation to overcome the drawbacks of each approach while preserving their advantages. Hybrid actuation and control have a considerable potential for walking rehabilitation but there is a need of novel control strategies of hybrid systems that adequately manage the balance between FES and robotic controllers. Combination of FES and robotic control is a challenging issue, due to the non-linear behavior of muscle under stimulation and the lack of developments in the field of hybrid control. In this article, a cooperative control strategy of a hybrid exoskeleton is presented. This strategy is designed to overcome the main disadvantages of muscular stimulation: electromechanical delay and change in muscle performance over time, and to balance muscular and robotic actuation during walking.Experimental results in healthy subjects show the ability of the hybrid FES-robot cooperative control to balance power contribution between exoskeleton and muscle stimulation. The robotic exoskeleton decreases assistance while adequate knee kinematics are guaranteed. A new technique to monitor muscle performance is employed, which allows to estimate muscle fatigue and implement muscle fatigue management strategies. Kinesis is therefore the first ambulatory hybrid exoskeleton that can effectively balance robotic and FES actuation during walking. This represents a new opportunity to implement new rehabilitation interventions to induce locomotor activity in patients with paraplegia.Acronym list: 10 mWT: ten meters walking test; 6 MWT: six minutes walking test; FSM: finite-state machine; t-FSM: time-domain FSM; c-FSM: cycle-domain FSM; FES: functional electrical stimulation; HKAFO: hip-knee-ankle-foot orthosis; ILC: iterative error-based learning control; MFE: muscle fatigue estimator; NILC: Normalized stimulation output from ILC controller; PID: Proportional-Integral-derivative Control; PW: Stimulation pulse width; QUEST: Quebec User Evaluation of Satisfaction with assistive Technology; SCI: Spinal cord injury; TTI: torque-time integral; VAS: Visual Analog Scale.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Optimum Settings for Automatic Controllers
Ziegler, J. G., & Nichols, N. B. (1942) · Journal of Fluids Engineering · doi:10.1115/1.4019264 · Cited by 5,212
A survey of iterative learning control
(2006) · IEEE Control Systems · doi:10.1109/mcs.2006.1636313 · Cited by 2,977 · cited 3×
“By incorporating error information into the control for subsequent iterations, high performance can be achieved with low transient tracking error in spite of large model uncertainty and repeating disturbances [56].”
BackgroundMethodOptimum Settings for Automatic Controllers
Ziegler, J. G., & Nichols, N. B. (1993) · Journal of Dynamic Systems Measurement and Control · doi:10.1115/1.2899060 · Cited by 2,460 · cited 2×
“Ziegler JG, Nichols N: Optimum settings for automatic controllers.”
MethodOptimum Setting for Automatic Controllers
Zieglar, J. G. (1942) · Medical Entomology and Zoology · Cited by 1,155
Esquenazi, A., Talaty, M., Packel, A., & Saulino, M. (2012) · American Journal of Physical Medicine & Rehabilitation · doi:10.1097/phm.0b013e318269d9a3 · Cited by 958 · cited 1×
“However, whilst there are some commercially available devices, like the ReWalk or Ekso, the technology is not mature enough to produce unlimited community ambulation yet [3,4].”
Patient- cooperative strategies for robot-aided treadmill training: first experimental results
Riener, R., Lunenburger, L., Jezernik, S., Anderschitz, M., Colombo, G., & Dietz, V. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.848628 · Cited by 729 · cited 1×
“Several research groups are recognizing these limitations of position controlled exoskeletons, implementing control schemes to provide a more flexible robot, adaptable to the functional capabilities of the user [27].”
BackgroundExoskeletons and orthoses: classification, design challenges and future directions
Herr, H. (2009) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-6-21 · Cited by 477
27th Annual International Conference of the IEEE Engineering in Medicine and Biology Society
(2005) · IEEE Transactions on Nanobioscience · doi:10.1109/tnb.2005.845677 · Cited by 288
Botter, A., Oprandi, G., Lanfranco, F., Allasia, S., Maffiuletti, N. A., & Minetto, M. A. (2011) · European Journal of Applied Physiology · doi:10.1007/s00421-011-2093-y · Cited by 260 · cited 1×
“Three electrodes (Alexgaard, Pals-platinum) were placed over the motor points of Vastus Lateralis, Rectus Femoris and Vastus Medialis knee extension muscles, and two electrodes over the motor points of Semitendinosus and Biceps Femoris knee flexion muscles [59].”
MethodFunctional electrical stimulation for walking in paraplegia.
Marsolais, E. B., & Kobetic, R. (1987) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198769050-00014 · Cited by 259 · cited 2×
“A considerable period of training (typically several weeks or even months) with electrical stimulation is required to apply such neuroprosthetic solution [38,40,61] or hybrid exoskeletons [15,16,21] for gait-related tasks in SCI, mainly due to changes in muscular characteristics after paralysis.”
Background
Cited by
Brain‐computer interfaces for post‐stroke motor rehabilitation: a meta‐analysis
Cervera, M. A., Soekadar, S. R., Ushiba, J., Millán, J. D. R., Liu, M., Birbaumer, N., & Garipelli, G. (2018) · Annals of Clinical and Translational Neurology · doi:10.1002/acn3.544 · Cited by 572
Systematic review on wearable lower-limb exoskeletons for gait training in neuromuscular impairments
Rodríguez-Fernández, A., Lobo-Prat, J., & Font-Llagunes, J. M. (2021) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-021-00815-5 · Cited by 435
Bortole, M., Venkatakrishnan, A., Zhu, F., Moreno, J. C., Francisco, G. E., Pons, J. L., & Contreras-Vidal, J. L. (2015) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-015-0048-y · Cited by 347
Self-citationOpportunities and challenges in the development of exoskeletons for locomotor assistance
Siviy, C., Baker, L. M., Quinlivan, B. T., Porciuncula, F., Swaminathan, K., Awad, L. N., & Walsh, C. J. (2022) · Nature Biomedical Engineering · doi:10.1038/s41551-022-00984-1 · Cited by 258
Robotic exoskeletons: The current pros and cons
Gorgey, A. S. (2018) · World Journal of Orthopedics · doi:10.5312/wjo.v9.i9.112 · Cited by 205
Ha, K. H., Murray, S. A., & Goldfarb, M. (2016) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2015.2421052 · Cited by 176
“In [42], the authors also describe a control method for combining FES with a powered knee joint, and implemented this method on five healthy subjects.”
MethodGad, P., Gerasimenko, Y., Zdunowski, S., Turner, A., Sayenko, D., Lu, D. C., & Edgerton, V. R. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00333 · Cited by 173
“Some of the experimental units include a brain computer interface (Lebedev and Nicolelis, 2011; Onose et al., 2016) or muscle stimulators (del-Ama et al., 2014), however, each of these units bypass the automaticity that is intrinsic to the spinal networks and do not allow voluntary effort from the…”
BackgroundClosed-loop functional optogenetic stimulation
Srinivasan, S. S., Maimon, B. E., Diaz, M., Song, H., & Herr, H. M. (2018) · Nature Communications · doi:10.1038/s41467-018-07721-w · Cited by 68
Dalla Gasperina, S., Ferrari, F., Gandolla, M., Pedrocchi, A., & Ambrosini, E. (2024) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2024.3384939 · Cited by 18
Metadata
- Authors
- del-Ama, A. J., Gil-Agudo, Á., Pons, J. L., & Moreno, J. C.
- Venue
- Journal of NeuroEngineering and Rehabilitation
- Published
- 2014
- Volume
- 11
- Issue
- 1
- Pages
- 27
- ISSN
- 1743-0003 (ISSN-L)
- OpenAlex
- W2058070720
- Cited by
- 190
- References
- 48
- FWCI
- 8.61
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.