CoChat

Comparison of three generations of ActiGraph activity monitors under free-living conditions: do they provide comparable assessments of overall physical activity in 9-year old children?

Open access
Grydeland, May, Hansen, Bjoerge Herman, Ried-Larsen, Mathias, Kolle, Elin, Anderssen, Sigmund Alfred · 2014 · BMC Sports Science, Medicine and Rehabilitation
Cited by 42

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

Abstract

BACKGROUND: A recent review concludes that the agreement of data across ActiGraph accelerometer models for children and youth still is uncertain. The aim of this study was to evaluate the agreement of three generations of ActiGraph accelerometers in children in a free-living condition. METHODS: Sixteen 9-year-olds wore the ActiGraph AM7164, GT1M and GT3X+ simultaneously for three consecutive days. We compared mean counts per minute (mcpm) and time spent at different intensities from the three generations of monitors, and the agreement of outputs were evaluated by intra-class correlation coefficients (ICC) and Bland-Altman plots. RESULTS: The ICC for mcpm was 0.985 (95% CI = 0.898, 0.996). We found a relative difference of 11.6% and 9.8% between the AM7164 and the GT1M and AM7164 and the GT3X+, respectively. The relative difference between mcpm assessed by the GT1M and GT3X+ was 1.7%. The inter-generation differences varied in magnitude and direction across intensity levels, with the largest difference found in the highest intensities. CONCLUSION: We found that the ActiGraph model AM7164 yields higher outputs of mean physical activity intensity (mcpm) than the models GT1M and GT3X+ in children in free-living conditions. The generations GT1M and GT3X+ provided comparable outputs. The differences between the old and the newer monitors were more complex when investigating time spent at different intensities. Comparisons of data assessed by the AM7164 with data assessed by newer generations ActiGraphs should be done with caution.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1186/2052-1847-6-26

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 9 references

Cited by

See all 42

Metadata

Authors
Grydeland, M., Hansen, B. H., Ried-Larsen, M., Kolle, E., & Anderssen, S. A.
Venue
BMC Sports Science, Medicine and Rehabilitation
Published
2014-06-28
Volume
6
Issue
1
Pages
26-26
ISSN
2052-1847 (ISSN-L)
OpenAlex
W2103697372
Cited by
42
References
9
FWCI
1.55
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparison of three generations of ActiGraph activity monitors under free-living conditions: do they provide comparable assessments of overall physical activity in 9-year old children? https://app.cochat.ai/papers/10.1186/2052-1847-6-26
The paper
Grydeland, M., Hansen, B. H., Ried-Larsen, M., Kolle, E., & Anderssen, S. A. (2014). Comparison of three generations of ActiGraph activity monitors under free-living conditions: do they provide comparable assessments of overall physical activity in 9-year old children? BMC Sports Science, Medicine and Rehabilitation. https://doi.org/10.1186/2052-1847-6-26

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.