CoChat

A research algorithm to improve detection of delirium in the intensive care unit

Open access
Pisani, Margaret A, Araujo, Katy LB, Van Ness, Peter H, Zhang, Ying, Ely, E Wesley, Inouye, Sharon K · 2006 · Critical Care
Cited by 136

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

Introduction: Delirium is a serious and prevalent problem in intensive care units (ICUs). The purpose of this study was to develop a research algorithm to enhance detection of delirium in critically ill ICU patients using chart review to complement a validated clinical delirium instrument. Methods: A prospective cohort study was conducted in 178 patients aged 60 years and older who were admitted to the medical ICU. The Confusion Assessment Method for the ICU (CAM-ICU) and a validated chart review method for detecting delirium were performed daily. We assessed the diagnostic accuracy of the chart-based delirium method using the CAM-ICU as the 'gold standard'. We then used an algorithm to detect delirium first using the CAM-ICU ratings and then chart review when the CAM-ICU was unavailable. Results: When using both the CAM-ICU and the chart-based review, the prevalence of delirium was found to be 80% of patients (143 out of 178) or 64% of patient-days (929 out of 1,457). Of these patient-days, 292 were classified as delirium by the CAM-ICU. The remainder (637 patient-days) were classified as delirium by the validated chart review method when CAM-ICU was missing because the assessment was conducted for weekends or holidays (404 patient-days), when CAM-ICU was not performed because of stupor or coma (205 patient-days), and when the CAM-ICU was negative (28 patient-days). Sensitivity of the chart-based method was 64% and specificity was 85%. Overall agreement between chart and the CAM-ICU was 72%. Conclusion: Eight out of 10 patients in this cohort study developed delirium in the ICU. Although use of a validated delirium instrument with frequent direct observations is recommended for clinical care, this approach may not always be feasible, especially in a research setting. The algorithm proposed here comprises a more comprehensive method for detecting delirium in a research setting, taking into account the fluctuation that occurs with delirium, which is a key component of accurate determination of delirium status. Improving detection of delirium is of paramount importance both to advance delirium research and to enhance clinical care and patient safety.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1186/cc5027

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

Metadata

Authors
Pisani, M. A., Araujo, K. L., Van Ness, P. H., Zhang, Y., Ely, E. W., & Inouye, S. K.
Venue
Critical Care
Published
2006-08-18
Volume
10
Issue
4
Pages
R121-R121
ISSN
1364-8535 (ISSN-L)
OpenAlex
W1828293320
Cited by
136
References
7
FWCI
7.74
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.