Auscultatory versus oscillometric blood pressure measurement in patients with atrial fibrillation and arterial hypertension
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
BACKGROUND: The aim of our study was to investigate the reliability of automated oscillometric blood pressure (BP) monitoring in the presence and absence of atrial fibrillation (AF) in hypertensive patients. METHODS: BP was measured and compared in 71 randomly selected patients with AF and arterial hypertension diagnosis, 4 times each by auscultatory and oscillometric (Microlife BP A6 PC with AF detection system) methods. RESULTS: Study included 71 patients: 36 males (mean age 67.4 years) and 35 females (70.2 years). At the time of BP measuring procedure, 36 patients were in sinus rhythm (SR) and 35 in AF. In SR patients mean systolic blood pressure (SBP) was 132 ± 17.9 mmHg with auscultatory method (AM), 137.4 ± 19.4 mmHg with oscillometric method (OM); mean diastolic BP was 77.1 ± 10.9 mmHg (AM), 78.5 ± 12.2 mmHg (OM), in AF patients mean SBP was 127.5 ± 15.1 mmHg (AM), 133.6 ± 17.4 mmHg (OM); mean diastolic BP was 81.4 ± 9.9 mmHg (AM), 83.5 ± 11.8 mmHg (OM), p = 0.037. The averages of differences for SBP and DBP in sinus rhythm group were (-5.3 mmHg (95% limits of agreement -27.2 - 16.6)) and (-1.4 mmHg (95% limits of agreement -12.8 - 10.0)), respectively. In patients with AF the averages of differences for SBP and DBP were (-6.1 mmHg (95% limits of agreement -23.9 - 11.7)) and (-2.1 mmHg (95% limits of agreement -12.9 - 8.7)), respectively. CONCLUSIONS: The oscillometric device validated for patients with AF on average gives 5.3 mmHg higher systolic BP values for patients with SR and 6.3 mmHg higher BP values for patients with AF. However, the limits of agreement between two methods reveal wide range of random error rates which is a questionable topic in clinical practice, as it could possibly affect the treatment of arterial hypertension in patients with AF.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Understanding bland altman analysis
Giavarina, D. (2015) · Biochemia Medica · doi:10.11613/bm.2015.015 · Cited by 4,706
O'Brien, E., Asmar, R., Beilin, L., Imai, Y., Mallion, J.-M., Mancia, G., Mengden, T., Myers, M., Padfield, P., Palatini, P., et al. (2003) · Journal of Hypertension · doi:10.1097/00004872-200305000-00001 · Cited by 1,655
Manolis, A. J., Rosei, E. A., Coca, A., Cifkova, R., Erdine, S. E., Kjeldsen, S., Lip, G. Y. H., Narkiewicz, K., Parati, G., Redon, J., et al. (2012) · Journal of Hypertension · doi:10.1097/hjh.0b013e32834f03bf · Cited by 198
Bilo, G., Zorzi, C., Ochoa Munera, J. E., Torlasco, C., Giuli, V., & Parati, G. (2015) · Blood Pressure Monitoring · doi:10.1097/mbp.0000000000000124 · Cited by 143
Automated blood pressure measurement in atrial fibrillation: a systematic review and meta-analysis
Stergiou, G. S., Kollias, A., Destounis, A., & Tzamouranis, D. (2012) · Journal of Hypertension · doi:10.1097/hjh.0b013e32835850d7 · Cited by 120
Cited by
2024 ESC Guidelines for the management of elevated blood pressure and hypertension
McEvoy, J. W., McCarthy, C. P., Bruno, R. M., Brouwers, S., Canavan, M. D., Ceconi, C., Christodorescu, R. M., Daskalopoulou, S. S., Ferro, C. J., Gerdts, E., et al. (2024) · European Heart Journal · doi:10.1093/eurheartj/ehae178 · Cited by 2,298
Stergiou, G. S., Kyriakoulis, K. G., Stambolliu, E., Destounis, A., Karpettas, N., Kalogeropoulos, P., & Kollias, A. (2019) · Journal of Hypertension · doi:10.1097/hjh.0000000000002201 · Cited by 67
Clark, C. E., McDonagh, S. T. J., & McManus, R. J. (2019) · Journal of Human Hypertension · doi:10.1038/s41371-018-0153-z · Cited by 49
“2); heterogeneity was accounted for by exclusion of one outlying study on the Microlife BP A6 (Microlife, Heerbrugg, Switzerland) [31], pooled difference from mercury on exclusion was −0.2 mmHg (−1.1 to 0.8; I2= 24%).”
BackgroundInfluentialMeasurement of blood pressure in people with atrial fibrillation
on behalf of the Blood Pressure Measurement Working Party of the British and Irish Hypertension Society, Clark, C. E., McDonagh, S. T. J., & McManus, R. J. (2019) · Journal of Human Hypertension · doi:10.1038/s41371-019-0261-4 · Cited by 16
Metadata
- Authors
- Šelmytė–Besusparė, A., Barysienė, J., Petrikonytė, D., Aidietis, A., Marinskis, G., & Laucevičius, A.
- Venue
- BMC Cardiovascular Disorders
- Published
- 2017-03-23
- Volume
- 17
- Issue
- 1
- Pages
- 87-87
- ISSN
- 1471-2261 (ISSN-L)
- OpenAlex
- W2598002044
- Cited by
- 18
- References
- 6
- FWCI
- 1.27
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Auscultatory versus oscillometric blood pressure measurement in patients with atrial fibrillation and arterial hypertension. https://app.cochat.ai/papers/10.1186/s12872-017-0521-6
- The paper
- Šelmytė–Besusparė, A., Barysienė, J., Petrikonytė, D., Aidietis, A., Marinskis, G., & Laucevičius, A. (2017). Auscultatory versus oscillometric blood pressure measurement in patients with atrial fibrillation and arterial hypertension. BMC Cardiovascular Disorders. https://doi.org/10.1186/s12872-017-0521-6
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.