CoChat

Metrics for evaluating 3D medical image segmentation: analysis, selection, and tool

Open access
Taha, Abdel Aziz, Hanbury, Allan · 2015 · BMC Medical Imaging
Cited by 2,920

The DOI matches its Crossref record; 61 of the 61 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Medical Image segmentation is an important image processing step. Comparing images to evaluate the quality of segmentation is an essential part of measuring progress in this research area. Some of the challenges in evaluating medical segmentation are: metric selection, the use in the literature of multiple definitions for certain metrics, inefficiency of the metric calculation implementations leading to difficulties with large volumes, and lack of support for fuzzy segmentation by existing metrics. RESULT: First we present an overview of 20 evaluation metrics selected based on a comprehensive literature review. For fuzzy segmentation, which shows the level of membership of each voxel to multiple classes, fuzzy definitions of all metrics are provided. We present a discussion about metric properties to provide a guide for selecting evaluation metrics. Finally, we propose an efficient evaluation tool implementing the 20 selected metrics. The tool is optimized to perform efficiently in terms of speed and required memory, also if the image size is extremely large as in the case of whole body MRI or CT volume segmentation. An implementation of this tool is available as an open source project. CONCLUSION: We propose an efficient evaluation tool for 3D medical image segmentation using 20 evaluation metrics and provide guidelines for selecting a subset of these metrics that is suitable for the data and the segmentation task.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1186/s12880-015-0068-x

Cites

61 of 61 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 17

  1. Fenster A, Chiu B. Evaluation of segmentation algorithms for medical imaging. In: Conf Proc IEEE Eng Med Biol Soc. Shanghai: 2005. p. 7186–189. · DOI
  2. Klement EP, Pap E, Mesiar R. Trends in logic. Netherlands: Springer; 2000. https://books.google.at/books?id=9HawzJbmXHUC .
  3. Al-Faris AQ, Ngah UK, Isa NAM, Shuaib IL. MRI breast skin-line segmentation and removal using integration method of level set active contour and morphological thinning algorithms. J Med Sci. 2013. doi: 10.3923/jms.2012.286.291 . · doi:10.3923/jms.2012.286.291
  4. Reddy AR, Prasad EV, Reddy LSS. Abnormality detection of brain mr image segmentation using iterative conditional mode algorithm. Int J Appl Inform Syst. 2013; 5(2):56–66.
  5. Reddy AR, Prasad EV, Reddy LSS. Comparative analysis of brain tumor detection using different segmentation techniques. Int J Comput Appl. 2013; 82(14):14–28.
  6. Hallermeier E, Rifqi M, Henzgen S, Senge R. Comparing fuzzy partitions: A generalization of the rand index and related measures. IEEE T Fuzzy Syst. 2012. doi: 10.1109/TFUZZ.2011.2179303 . · doi:10.1109/tfuzz.2011.2179303
  7. Zhao J, Long C, Xiong S, Liu C, Yua Z. A new k nearest neighbors search algorithm using cell grids for 3d scattered point cloud. Electron Electrical Eng. 2014; 20(1). doi: 10.5755/j01.eee.20.1.3926 . · doi:10.5755/j01.eee.20.1.3926
  8. Sladoje N, Lindblad J, Nystrom I. Defuzzification of spatial fuzzy sets by feature distance minimization. Image Vis Comput. 2011; 29:127–41. · doi:10.1016/j.imavis.2010.08.007
  9. Tustison NJ, Siqueira M, Gee JC. N-D linear time exact signed Euclidean distance transform. The Insight Journal. 2006. http://hdl.handle.net/1926/171 .
  10. Eric B, Andriy F, Nikos C. The use of robust local Hausdorff distances in accuracy assessment for image alignment of brain MRI. The Insight Journal. 2008. doi: 10.1007/978-3-540-89639-5_57 . · DOI
  11. Klein S, van der Heide UA, Raaymakers BW, Kotte ANTJ, Staring M, Pluim JPW. Segmentation of the prostate in mr images by atlas matching. In: ISBI. Arlington, VA: 2007. p. 1300–3. · doi:10.1109/isbi.2007.357098
  12. Cai X, Hou Y, Li C, Lee J, Wee WG. 2006. Evaluation of two segmentation methods on mri brain tissue structures. · doi:10.1109/iembs.2006.260725
  13. Keyvan K, Mohammad Javad D, Kamran K, Mohammad Sadegh H, Kafshgari S. Comparison evaluation of three brain mri segmentation methods in software tools. In: Biomedical Engineering (ICBME). Isfahan: 2010. p. 1–4. · DOI
  14. (Menze B, Jakab A, Bauer S, Reyes M, Prastawa M, Leemput KV, editors.)2012. MICCAI 2012 Challenge on Multimodal Brain Tumor Segmentation BRATS2012. Nice, France: MICCAI. http://www2.imm.dtu.dk/projects/BRATS2012/ .
  15. Yadav S, Meshram S. Performance evaluation of basic segmented algorithms for brain tumor detection. J Electron Commun Eng IOSR. 2013; 5:08–13. · doi:10.9790/2834-560813
  16. Morain-Nicolier F, Lebonvallet S, Baudrier E, Ruan S. Hausdorff distance based 3D quantification of brain tumor evolution from MRI images. In: 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. Lyon, France: 2007. p. 5597–600. · doi:10.1109/iembs.2007.4353615
  17. Narendran P, Narendira Kumar VK, Somasundaram K. 3D Brain Tumors and internal brain structures segmentation in mr images. Int J Image Graphics Signal Process. 2012; 1:ISSN: 2074-9074.

Cited by

See all 2,920

Metadata

Authors
Taha, A. A., & Hanbury, A.
Venue
BMC Medical Imaging
Published
2015-08-12
Volume
15
Issue
1
Pages
29-29
ISSN
1471-2342 (ISSN-L)
OpenAlex
W1909740415
Cited by
2,920
References
61
FWCI
45.06
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.