Antidepressant outcomes of high-frequency repetitive transcranial magnetic stimulation (rTMS) with F8-coil and deep transcranial magnetic stimulation (DTMS) with H1-coil in major depression: a systematic review and meta-analysis
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
BACKGROUND: The current study aims to systematically assess and compare the antidepressant outcomes of repetitive transcranial magnetic stimulation (rTMS) with the figure-of-eight (F8)-coil and deep transcranial magnetic stimulation (DTMS) with the H1-coil in studies matched on stimulation frequency in unipolar major depressive disorder (MDD). METHODS: Electronic search of Medline and PsycInfo identified 19 studies with stimulation frequency of 18-20 Hz using F8-coil (k = 8 randomised sham-controlled trials, RCTs, k = 3 open-label; n = 168 patients) or H1-coil (k = 1 RCT, k = 7 open-label; n = 200). Depression severity (the primary outcome) and response/remission rates (the secondary outcomes) were assessed at session 10. RESULTS: Effects pooled with random-effects meta-analysis showed a large reduction in depression severity, 29% response, and 15% remission rates after 10 sessions of active stimulation with either coil relative to baseline. Reduction in depression severity was greater in studies with younger patients using either coil. The comparison between coils showed a larger reduction in depression severity in H1-coil vs. F8-coil studies (independent of the study design or the concurrent pharmacotherapy) and a trend towards higher remission rates in F8-coil vs. H1-coils studies. These effects are based on a low volume of studies, are not controlled for placebo, and may not be clinically-relevant. The stimulation protocols differed systematically because stimulation was more focal but less intense (80-110% of the resting motor threshold, MT) in the F8-coil studies and less focal but more intense (120% MT) in the H1-coil studies. Two seizures occurred in the H1-coil studies relative to none in the F8-coil studies. CONCLUSION: When matched on frequency, the higher-intensity and less focal stimulation with the H1-coil reduces depression more than the lower-intensity and more focal stimulation with the F8-coil. Head-to-head trials should compare the antidepressant outcomes of F8-coil and H1-coil to identify the most optimal stimulation protocols for acute and longer-lasting efficacy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
George, M. S., Lisanby, S. H., Avery, D., McDonald, W. M., Durkalski, V., Pavlicova, M., Anderson, B., Nahas, Z., Bulow, P., Zarkowski, P., et al. (2010) · Archives of General Psychiatry · doi:10.1001/archgenpsychiatry.2010.46 · Cited by 1,092 · cited 1×
“The open-label extensions to the largest RCTs in the field [2, 9] have shown that some patients experience a delayed response and require 4–6 weeks of stimulation before showing adequate response to treatment with F8-coil or H1-coil [37, 38].”
BackgroundBerlim, M. T., van den Eynde, F., Tovar-Perdomo, S., & Daskalakis, Z. J. (2014) · Psychological Medicine · doi:10.1017/s0033291713000512 · Cited by 620 · cited 2×
“In general, the efficacy of both methods (F8-coil and H1-coil) with highly variable stimulation protocols is comparable in magnitude based on the moderate acute effects observed in the double-blind, sham-controlled RCTs with MDD patients [1, 3, 9, 43].”
BackgroundMethodLevkovitz, Y., Isserles, M., Padberg, F., Lisanby, S. H., Bystritsky, A., Xia, G., Tendler, A., Daskalakis, Z. J., Winston, J. L., Dannon, P., et al. (2015) · World Psychiatry · doi:10.1002/wps.20199 · Cited by 442 · cited 20×
“…open-label Yukimasa et al., 2006 F8 0.19 0.08 0.39 5 / 26 open-label Luborzewski et al., 2007F8 0.35 0.17 0.60 6 / 17 open-label 0.32 0.23 0.42 RCT Levkovitz et al., 2015 H1 0.15 0.09 0.24 13 / 89 RCT George et al., 1997 F8 0.14 0.02 0.58 1 / 7 RCT Berman et al., 2000 F8 0.10 0.01 0.47 1 / 10 RCT…”
BackgroundMethodInfluentialGuse, B., Falkai, P., & Wobrock, T. (2010) · Journal of Neural Transmission · doi:10.1007/s00702-009-0333-7 · Cited by 340 · cited 1×
“The overwhelming volume of evidence suggests that rTMS or DTMS with higher frequencies produces greater beneficial effects by alleviating symptom severity and improving cognition in MDD [34, 60, 61].”
BackgroundLisanby, S. H., Husain, M. M., Rosenquist, P. B., Maixner, D., Gutierrez, R., Krystal, A., Gilmer, W., Marangell, L. B., Aaronson, S., Daskalakis, Z. J., et al. (2009) · Neuropsychopharmacology · doi:10.1038/npp.2008.118 · Cited by 333 · cited 2×
“However, it is also in line with previous studies that did not consistently identify predictors of response to rTMS or DTMS using primary and secondary analyses [3, 37, 49, 50].”
BackgroundResultCoil design considerations for deep transcranial magnetic stimulation
Deng, Z.-D., Lisanby, S. H., & Peterchev, A. V. (2014) · Clinical Neurophysiology · doi:10.1016/j.clinph.2013.11.038 · Cited by 308
Kedzior, K. K., Gerkensmeier, I., & Schuchinsky, M. (2018) · BMC Psychiatry · doi:10.1186/s12888-018-1704-0 · Cited by 25 · cited 1×
“A consistent reduction of symptoms in some substance use disorders indirectly suggests that the H-coils may target deeper reward pathways [7] although the issue of depth is not resolved yet.”
BackgroundSelf-citation
Cited by
Trapp, N. T., Purgianto, A., Taylor, J. J., Singh, M. K., Oberman, L. M., Mickey, B. J., Youssef, N. A., Solzbacher, D., Zebley, B., Cabrera, L. Y., et al. (2025) · Clinical Neurophysiology · doi:10.1016/j.clinph.2024.12.015 · Cited by 89
Fitzgerald, P. B. (2020) · Journal of Affective Disorders · doi:10.1016/j.jad.2020.06.067 · Cited by 69
Asgharian Asl, F., & Vaghef, L. (2022) · Journal of Psychiatric Research · doi:10.1016/j.jpsychires.2022.01.025 · Cited by 58
Brini, S., Brudasca, N. I., Hodkinson, A., Kaluzinska, K., Wach, A., Storman, D., Prokop-Dorner, A., Jemioło, P., & Bala, M. M. (2023) · Clinical Psychology Review · doi:10.1016/j.cpr.2022.102236 · Cited by 44
Brain PET metabolic substrate of TMS response in pharmaco-resistant depression
Tastevin, M., Richieri, R., Boyer, L., Fond, G., Lançon, C., & Guedj, E. (2020) · Brain Stimulation · doi:10.1016/j.brs.2020.02.014 · Cited by 10
Metadata
- Authors
- Gellersen, H. M., & Kedzior, K. K.
- Venue
- BMC Psychiatry
- Published
- 2019-05-07
- Volume
- 19
- Issue
- 1
- Pages
- 139-139
- ISSN
- 1471-244X (ISSN-L)
- OpenAlex
- W2943929455
- Cited by
- 38
- References
- 7
- FWCI
- 0.63
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Antidepressant outcomes of high-frequency repetitive transcranial magnetic stimulation (rTMS) with F8-coil and deep transcranial magnetic stimulation (DTMS) with H1-coil in major depression: a systematic review and meta-analysis. https://app.cochat.ai/papers/10.1186/s12888-019-2106-7
- The paper
- Gellersen, H. M., & Kedzior, K. K. (2019). Antidepressant outcomes of high-frequency repetitive transcranial magnetic stimulation (rTMS) with F8-coil and deep transcranial magnetic stimulation (DTMS) with H1-coil in major depression: a systematic review and meta-analysis. BMC Psychiatry. https://doi.org/10.1186/s12888-019-2106-7
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.