CoChat

The effect of changing movement and posture using motion-sensor biofeedback, versus guidelines-based care, on the clinical outcomes of people with sub-acute or chronic low back pain-a multicentre, cluster-randomised, placebo-controlled, pilot trial

Open access
Kent, Peter, Laird, Robert, Haines, Terry · 2015 · BMC Musculoskeletal Disorders
Cited by 109

The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.

Abstract

BACKGROUND: The aims of this pilot trial were to (i) test the hypothesis that modifying patterns of painful lumbo-pelvic movement using motion-sensor biofeedback in people with low back pain would lead to reduced pain and activity limitation compared with guidelines-based care, and (ii) facilitate sample size calculations for a fully powered trial. METHODS: A multicentre (8 clinics), cluster-randomised, placebo-controlled pilot trial compared two groups of patients seeking medical or physiotherapy primary care for sub-acute and chronic back pain. It was powered for longitudinal analysis, but not for adjusted single-time point comparisons. The intervention group (n = 58) received modification of movement patterns augmented by motion-sensor movement biofeedback (ViMove, dorsaVi.com) plus guidelines-based medical or physiotherapy care. The control group (n = 54) received a placebo (wearing the motion-sensors without biofeedback) plus guidelines-based medical or physiotherapy care. Primary outcomes were self-reported pain intensity (VAS) and activity limitation (Roland Morris Disability Questionnaire (RMDQ), Patient Specific Functional Scale (PSFS)), all on 0-100 scales. Both groups received 6-8 treatment sessions. Outcomes were measured seven times during 10-weeks of treatment and at 12, 26 and 52 week follow-up, with 17.0 % dropout. Patients were not informed of group allocation or the study hypothesis. RESULTS: Across one-year, there were significant between-group differences favouring the intervention group [generalized linear model coefficient (95 % CI): group effect RMDQ -7.1 (95 % CI-12.6;-1.6), PSFS -10.3 (-16.6; -3.9), QVAS -7.7 (-13.0; -2.4); and group by time effect differences (per 100 days) RMDQ -3.5 (-5.2; -2.2), PSFS -4.7 (-7.0; -2.5), QVAS -4.8 (-6.1; -3.5)], all p < 0.001. Risk ratios between groups of probability of improving by >30 % at 12-months = RMDQ 2.4 (95 % CI 1.5; 4.1), PSFS 2.5 (1.5; 4.0), QVAS 3.3 (1.8; 5.9). The only device-related side-effects involved transient skin irritation from tape used to mount motion sensors. CONCLUSIONS: Individualised movement retraining using motion-sensor biofeedback resulted in significant and sustained improvements in pain and activity limitation that persisted after treatment finished. This pilot trial also refined the procedures and sample size requirements for a fully powered RCT. This trial (Australian New Zealand Clinical Trials Registry NCT01572779) was equally funded by dorsaVi P/L and the Victorian State Government.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1186/s12891-015-0591-5

Cites

16 of 16 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 16 references

Cited by

See all 109

Metadata

Authors
Kent, P., Laird, R., & Haines, T.
Venue
BMC Musculoskeletal Disorders
Published
2015-05-29
Volume
16
Issue
1
Pages
131-131
ISSN
1471-2474 (ISSN-L)
OpenAlex
W1605076520
Cited by
109
References
16
FWCI
6.13
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The effect of changing movement and posture using motion-sensor biofeedback, versus guidelines-based care, on the clinical outcomes of people with sub-acute or chronic low back pain-a multicentre, cluster-randomised, placebo-controlled, pilot trial. https://app.cochat.ai/papers/10.1186/s12891-015-0591-5
The paper
Kent, P., Laird, R., & Haines, T. (2015). The effect of changing movement and posture using motion-sensor biofeedback, versus guidelines-based care, on the clinical outcomes of people with sub-acute or chronic low back pain-a multicentre, cluster-randomised, placebo-controlled, pilot trial. BMC Musculoskeletal Disorders. https://doi.org/10.1186/s12891-015-0591-5

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.