The effect of changing movement and posture using motion-sensor biofeedback, versus guidelines-based care, on the clinical outcomes of people with sub-acute or chronic low back pain-a multicentre, cluster-randomised, placebo-controlled, pilot trial
Open accessThe DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Abstract
BACKGROUND: The aims of this pilot trial were to (i) test the hypothesis that modifying patterns of painful lumbo-pelvic movement using motion-sensor biofeedback in people with low back pain would lead to reduced pain and activity limitation compared with guidelines-based care, and (ii) facilitate sample size calculations for a fully powered trial. METHODS: A multicentre (8 clinics), cluster-randomised, placebo-controlled pilot trial compared two groups of patients seeking medical or physiotherapy primary care for sub-acute and chronic back pain. It was powered for longitudinal analysis, but not for adjusted single-time point comparisons. The intervention group (n = 58) received modification of movement patterns augmented by motion-sensor movement biofeedback (ViMove, dorsaVi.com) plus guidelines-based medical or physiotherapy care. The control group (n = 54) received a placebo (wearing the motion-sensors without biofeedback) plus guidelines-based medical or physiotherapy care. Primary outcomes were self-reported pain intensity (VAS) and activity limitation (Roland Morris Disability Questionnaire (RMDQ), Patient Specific Functional Scale (PSFS)), all on 0-100 scales. Both groups received 6-8 treatment sessions. Outcomes were measured seven times during 10-weeks of treatment and at 12, 26 and 52 week follow-up, with 17.0 % dropout. Patients were not informed of group allocation or the study hypothesis. RESULTS: Across one-year, there were significant between-group differences favouring the intervention group [generalized linear model coefficient (95 % CI): group effect RMDQ -7.1 (95 % CI-12.6;-1.6), PSFS -10.3 (-16.6; -3.9), QVAS -7.7 (-13.0; -2.4); and group by time effect differences (per 100 days) RMDQ -3.5 (-5.2; -2.2), PSFS -4.7 (-7.0; -2.5), QVAS -4.8 (-6.1; -3.5)], all p < 0.001. Risk ratios between groups of probability of improving by >30 % at 12-months = RMDQ 2.4 (95 % CI 1.5; 4.1), PSFS 2.5 (1.5; 4.0), QVAS 3.3 (1.8; 5.9). The only device-related side-effects involved transient skin irritation from tape used to mount motion sensors. CONCLUSIONS: Individualised movement retraining using motion-sensor biofeedback resulted in significant and sustained improvements in pain and activity limitation that persisted after treatment finished. This pilot trial also refined the procedures and sample size requirements for a fully powered RCT. This trial (Australian New Zealand Clinical Trials Registry NCT01572779) was equally funded by dorsaVi P/L and the Victorian State Government.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Vos, T., Flaxman, A. D., Naghavi, M., Lozano, R., Michaud, C., Ezzati, M., Shibuya, K., Salomon, J. A., Abdalla, S., Aboyans, V., et al. (2012) · The Lancet · doi:10.1016/s0140-6736(12)61729-2 · Cited by 8,291
Farrar, J. T., Young, J. P., LaMoreaux, L., Werth, J. L., & Poole, M. R. (2001) · Pain · doi:10.1016/s0304-3959(01)00349-9 · Cited by 5,808
Waddell, G., Newton, M., Henderson, I., Somerville, D., & Main, C. J. (1993) · Pain · doi:10.1016/0304-3959(93)90127-b · Cited by 3,167 · cited 1×
“Fear of movement was measured using the Fear Avoidance Beliefs Questionnaire physical activity subscale (FABQpa, 0 to 24 scale) [62].”
MethodChapter 4 European guidelines for the management of chronic nonspecific low back pain
Airaksinen, O., Brox, J. I., Cedraschi, C., Hildebrandt, J., Klaber-Moffett, J., Kovacs, F., Mannion, A. F., Reis, S., Staal, J. B., Ursin, H., et al. (2006) · European Spine Journal · doi:10.1007/s00586-006-1072-1 · Cited by 2,594
Ostelo, R. W. J. G., Deyo, R. A., Stratford, P., Waddell, G., Croft, P., Von Korff, M., Bouter, L. M., & de Vet, H. C. (2008) · Spine · doi:10.1097/brs.0b013e31815e3a10 · Cited by 2,009 · cited 3×
“Furthermore, across all these outcome measures, the additional (unadjusted) percentage improvement in the Movement Biofeedback Group ranged from 15 % to 27 % at 3 months and 35 % to 47 % at 12 months, which were all above the threshold for clinically important difference (>30 % of baseline scores) [67].”
BackgroundInfluentialThe economic burden of back pain in the UK
Maniadakis, N., & Gray, A. (2000) · Pain · doi:10.1016/s0304-3959(99)00187-6 · Cited by 1,510 · cited 1×
“7 % of GDP, depending on the country and the econometric model used [2, 3].”
BackgroundHill, J. C., Whitehurst, D. G., Lewis, M., Bryan, S., Dunn, K. M., Foster, N. E., Konstantinou, K., Main, C. J., Mason, E., Somerville, S., et al. (2011) · The Lancet · doi:10.1016/s0140-6736(11)60937-9 · Cited by 1,306
Chapter 3 European guidelines for the management of acute nonspecific low back pain in primary care
van Tulder, M., Becker, A., Bekkering, T., Breen, A., del Real, M. T. G., Hutchinson, A., Koes, B., Laerum, E., Malmivaara, A., & On behalf of the COST B13 Working Group on Guidelines for the Management of Acute Low Back Pain in Primary Care (2006) · European Spine Journal · doi:10.1007/s00586-006-1071-2 · Cited by 1,258
O’Sullivan, P. (2005) · Manual Therapy · doi:10.1016/j.math.2005.07.001 · Cited by 985
Exercise therapy for treatment of non-specific low back pain
Hayden, J., van Tulder, M. W., Malmivaara, A., & Koes, B. W. (2005) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd000335.pub2 · Cited by 879 · cited 2×
“These results are unusual and encouraging because they show moderate to large effects at the end of the 10-week treatment period that remained or increased at the 12 month follow-up, in a health condition where interventions typically show small to moderate effects [8] that are not sustained 12 months later [9–11].”
BackgroundResult
Cited by
Noah, B., Keller, M. S., Mosadeghi, S., Stein, L., Johl, S., Delshad, S., Tashjian, V. C., Lew, D., Kwan, J. T., Jusufagic, A., et al. (2018) · npj Digital Medicine · doi:10.1038/s41746-017-0002-4 · Cited by 273
“randomized 112 participants in eight clinics between wearing active wireless motion sensors placed along the spine, and placebo sensors while receiving physical therapy and guideline-based care.(28) Participants received six to eight physical therapy treatment sessions over 10 weeks and were followed for a year.”
BackgroundAreias, A. C., Costa, F., Janela, D., Molinos, M., Moulder, R. G., Lains, J., Scheer, J. K., Bento, V., Yanamadala, V., & Correia, F. D. (2022) · Healthcare · doi:10.3390/healthcare10122349 · Cited by 15
Technological Interventions for Pain Management
Suso-Ribera, C., Castilla, D., Martínez-Borba, V., Jaén, I., Botella, C., Baños, R. M., & García-Palacios, A. (2022) · Comprehensive Clinical Psychology · doi:10.1016/b978-0-12-818697-8.00009-1 · Cited by 6
Metadata
- Authors
- Kent, P., Laird, R., & Haines, T.
- Venue
- BMC Musculoskeletal Disorders
- Published
- 2015-05-29
- Volume
- 16
- Issue
- 1
- Pages
- 131-131
- ISSN
- 1471-2474 (ISSN-L)
- OpenAlex
- W1605076520
- Cited by
- 109
- References
- 16
- FWCI
- 6.13
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The effect of changing movement and posture using motion-sensor biofeedback, versus guidelines-based care, on the clinical outcomes of people with sub-acute or chronic low back pain-a multicentre, cluster-randomised, placebo-controlled, pilot trial. https://app.cochat.ai/papers/10.1186/s12891-015-0591-5
- The paper
- Kent, P., Laird, R., & Haines, T. (2015). The effect of changing movement and posture using motion-sensor biofeedback, versus guidelines-based care, on the clinical outcomes of people with sub-acute or chronic low back pain-a multicentre, cluster-randomised, placebo-controlled, pilot trial. BMC Musculoskeletal Disorders. https://doi.org/10.1186/s12891-015-0591-5
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.