Constrained transformer network for ECG signal processing and arrhythmia classification
Open accessThe DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Abstract
Background: Heart disease diagnosis is a challenging task and it is important to explore useful information from the massive amount of electrocardiogram (ECG) records of patients. The high-precision diagnostic identification of ECG can save clinicians and cardiologists considerable time while helping reduce the possibility of misdiagnosis at the same time.Currently, some deep learning-based methods can effectively perform feature selection and classification prediction, reducing the consumption of manpower. Methods: In this work, an end-to-end deep learning framework based on convolutional neural network (CNN) is proposed for ECG signal processing and arrhythmia classification. In the framework, a transformer network is embedded in CNN to capture the temporal information of ECG signals and a new link constraint is introduced to the loss function to enhance the classification ability of the embedding vector. Results: To evaluate the proposed method, extensive experiments based on real-world data were conducted. Experimental results show that the proposed model achieve better performance than most baselines. The experiment results also proved that the transformer network pays more attention to the temporal continuity of the data and captures the hidden deep features of the data well. The link constraint strengthens the constraint on the embedded features and effectively suppresses the effect of data imbalance on the results. Conclusions: In this paper, an end-to-end model is used to process ECG signal and classify arrhythmia. The model combine CNN and Transformer network to extract temporal information in ECG signal and is capable of performing arrhythmia classification with acceptable accuracy. The model can help cardiologists perform assisted diagnosis of heart disease and improve the efficiency of healthcare delivery.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
1 retracted
Varatharajan, R., Manogaran, G., & Priyan, M. K. (2018) · Multimedia Tools and Applications · doi:10.1007/s11042-017-5318-1 · Cited by 207
RetractedAdvances in neural information processing systems 7
Cios, K., & Shields, M. (1997) · Neurocomputing · doi:10.1016/s0925-2312(97)90018-7 · Cited by 22,059
Batch Normalization: Accelerating Deep Network Training by Reducing Internal Covariate Shift
Ioffe, S. (2024) · arXiv (Cornell University) · doi:10.57702/o9raffed · Cited by 14,214
Show and tell: A neural image caption generator
Vinyals, O., Toshev, A., Bengio, S., & Erhan, D. (2015) · 2015 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2015.7298935 · Cited by 6,318 · cited 2×
“Five SOTA deep-learning models were employed as base-lines to compare with CNN_Trans-former_LC: A CNN [32], ResNet [33], Multi_channelCNN [34], BiRNN [21], and CNN_BiLSTM [30].”
MethodWIDROW, B., & HOFF, M. E. (1960) · doi:10.21236/ad0241531 · Cited by 4,009
Hannun, A. Y., Rajpurkar, P., Haghpanahi, M., Tison, G. H., Bourn, C., Turakhia, M. P., & Ng, A. Y. (2019) · Nature Medicine · doi:10.1038/s41591-018-0268-3 · Cited by 3,148
CNN architectures for large-scale audio classification
Hershey, S., Chaudhuri, S., Ellis, D. P. W., Gemmeke, J. F., Jansen, A., Moore, R. C., Plakal, M., Platt, D., Saurous, R. A., Seybold, B., et al. (2017) · 2017 IEEE International Conference on Acoustics, Speech and Signal Processing (ICASSP) · doi:10.1109/icassp.2017.7952132 · Cited by 2,023
Real-Time Patient-Specific ECG Classification by 1-D Convolutional Neural Networks
Kiranyaz, S., Ince, T., & Gabbouj, M. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2468589 · Cited by 1,912
Feigin, V. L., Roth, G. A., Naghavi, M., Parmar, P., Krishnamurthi, R., Chugh, S., Mensah, G. A., Norrving, B., Shiue, I., Ng, M., et al. (2016) · The Lancet Neurology · doi:10.1016/s1474-4422(16)30073-4 · Cited by 1,691
Automatic Classification of Heartbeats Using ECG Morphology and Heartbeat Interval Features
deChazal, P., O'Dwyer, M., & Reilly, R. B. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.827359 · Cited by 1,671
Cited by
A comprehensive survey on applications of transformers for deep learning tasks
Islam, S., Elmekki, H., Elsebai, A., Bentahar, J., Drawel, N., Rjoub, G., & Pedrycz, W. (2024) · Expert Systems with Applications · doi:10.1016/j.eswa.2023.122666 · Cited by 487
Machine learning-based heart disease diagnosis: A systematic literature review
Ahsan, M. M., & Siddique, Z. (2022) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2022.102289 · Cited by 416
A transformer-based deep neural network for arrhythmia detection using continuous ECG signals
Hu, R., Chen, J., & Zhou, L. (2022) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2022.105325 · Cited by 225
Transformers and large language models in healthcare: A review
Nerella, S., Bandyopadhyay, S., Zhang, J., Contreras, M., Siegel, S., Bumin, A., Silva, B., Sena, J., Shickel, B., Bihorac, A., et al. (2024) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2024.102900 · Cited by 197
“A transformer network embedded inside a CNN architecture has been used to classify arrythmias [410].”
Metadata
- Authors
- Che, C., Zhang, P., Zhu, M., Qu, Y., & Jin, B.
- Venue
- BMC Medical Informatics and Decision Making
- Published
- 2021-06-09
- Volume
- 21
- Issue
- 1
- Pages
- 184-184
- ISSN
- 1472-6947 (ISSN-L)
- OpenAlex
- W3167986199
- Cited by
- 186
- References
- 34
- FWCI
- 15.89
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Constrained transformer network for ECG signal processing and arrhythmia classification. https://app.cochat.ai/papers/10.1186/s12911-021-01546-2
- The paper
- Che, C., Zhang, P., Zhu, M., Qu, Y., & Jin, B. (2021). Constrained transformer network for ECG signal processing and arrhythmia classification. BMC Medical Informatics and Decision Making. https://doi.org/10.1186/s12911-021-01546-2
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.