High concentrations of illicit stimulants and cutting agents cause false positives on fentanyl test strips
Open accessPublished version of a preprint
The DOI matches its Crossref record; 23 of the 24 references it cites were found in a registry or an index.
Abstract
Background: The opioid epidemic has caused an increase in overdose deaths which can be attributed to fentanyl combined with various illicit substances. Drug checking programs have been started by many harm reduction groups to provide tools for users to determine the composition of their street drugs. Immunoassay fentanyl test strips (FTS) allow users to test drugs for fentanyl by either filling a baggie or cooker with water to dissolve the sample and test. The antibody used in FTS is very selective for fentanyl at high dilutions, a characteristic of the traditional use of urine testing. These street sample preparation methods can lead to mg/mL concentrations of several potential interferents. We tested whether these concentrated samples could cause false positive results on a FTS. Methods: 20 ng/mL Rapid Response FTS were obtained from BTNX Inc. and tested against 4 different pharmaceuticals (diphenhydramine, alprazolam, gabapentin, and naloxone buprenorphine) and 3 illicit stimulants [cocaine HCl, methamphetamine, and 3,4-methylenedioxymethamphetamine (MDMA)] in concentrations from 20 to 0.2 mg/mL. The FTS testing pad is divided into 2 sections: the control area and the test area. Control and test area signal intensities were quantified by ImageJ from photographs of the test strips and compared to a threshold set by fentanyl at the FTS limit of detection. Results: False positive results indicating the presence of fentanyl were obtained from samples of methamphetamine, MDMA, and diphenhydramine at concentrations at or above 1 mg/mL. Diphenhydramine is a common cutting agent in heroin. The street sample preparation protocols for FTS use suggested by many online resources would produce such concentrations of these materials. Street samples need to be diluted more significantly to avoid interference from potential cutting agents and stimulants. Conclusions: Fentanyl test strips are commercially available, successful at detecting fentanyl to the specified limit of detection and can be a valuable tool for harm reduction efforts. Users should be aware that when drugs and adulterants are in high concentrations, FTS can give a false positive result.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures





Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“it has been demonstrated that high concentrations (≥ 1 mg/mL) of MDMA, methamphetamine, levamisole, and diphenhydramine produce false positive results with FTS [39, 45, 57].”
From Nitazene test strips: a laboratory evaluation (2024) · cites this paper as [57]
Experimental — accuracy not yet measuredThe check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“caffeine is one of the most commonly detected cutting agents in illicit drug samples, including street heroin, cocaine, and amphetamines [19].”
From Evaluation of nitazene immunoassay test strips for rapid in-situ detection of nitazene and nitazene analogs in illicit drug samples (2025) · cites this paper as [19]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Drug harms in the UK: a multicriteria decision analysis
Nutt, D. J., King, L. A., & Phillips, L. D. (2010) · The Lancet · doi:10.1016/s0140-6736(10)61462-6 · Cited by 1,681
Drug Overdose Deaths in the United States, 1999–2020
Hedegaard, H., Miniño, A., Spencer, M. R., & Warner, M. (2021) · doi:10.15620/cdc:112340 · Cited by 1,283
The ‘risk environment’: A framework for understanding and reducing drug-related harm
Rhodes, T. (2002) · International Journal of Drug Policy · doi:10.1016/s0955-3959(02)00007-5 · Cited by 1,241
(2022) · doi:10.15620/cdc:122556 · Cited by 562
Harper, L., Powell, J., & Pijl, E. M. (2017) · Harm Reduction Journal · doi:10.1186/s12954-017-0179-5 · Cited by 337
O’Donnell, J., Gladden, R. M., Mattson, C. L., Hunter, C. T., & Davis, N. L. (2020) · MMWR. Morbidity and Mortality Weekly Report · doi:10.15585/mmwr.mm6935a1 · Cited by 245
Antiretroviral drugs and liver injury
Soriano, V., Puoti, M., Garcia-Gascó, P., Rockstroh, J. K., Benhamou, Y., Barreiro, P., & McGovern, B. (2008) · AIDS · doi:10.1097/qad.0b013e3282f0e2fd · Cited by 216
Green, T. C., Park, J. N., Gilbert, M., McKenzie, M., Struth, E., Lucas, R., Clarke, W., & Sherman, S. G. (2020) · International Journal of Drug Policy · doi:10.1016/j.drugpo.2020.102661 · Cited by 211
Karamouzian, M., Dohoo, C., Forsting, S., McNeil, R., Kerr, T., & Lysyshyn, M. (2018) · Harm Reduction Journal · doi:10.1186/s12954-018-0252-8 · Cited by 209
Goldman, J. E., Waye, K. M., Periera, K. A., Krieger, M. S., Yedinak, J. L., & Marshall, B. D. L. (2019) · Harm Reduction Journal · doi:10.1186/s12954-018-0276-0 · Cited by 183
Recent Increases in Cocaine-Related Overdose Deaths and the Role of Opioids
McCall Jones, C., Baldwin, G. T., & Compton, W. M. (2017) · American Journal of Public Health · doi:10.2105/ajph.2016.303627 · Cited by 175
The role of harm reduction in controlling HIV among injecting drug users
WODAK, A. D., & McLeod, L. (2008) · AIDS · doi:10.1097/01.aids.0000327439.20914.33 · Cited by 121
DARK Classics in Chemical Neuroscience: Fentanyl
Burns, S. M., Cunningham, C. W., & Mercer, S. L. (2018) · ACS Chemical Neuroscience · doi:10.1021/acschemneuro.8b00174 · Cited by 103
McCrae, K., Tobias, S., Grant, C., Lysyshyn, M., Laing, R., Wood, E., & Ti, L. (2020) · Drug and Alcohol Review · doi:10.1111/dar.13004 · Cited by 98
Agency in the fentanyl era: Exploring the utility of fentanyl test strips in an opaque drug market
Weicker, N. P., Owczarzak, J., Urquhart, G., Park, J. N., Rouhani, S., Ling, R., Morris, M., & Sherman, S. G. (2020) · International Journal of Drug Policy · doi:10.1016/j.drugpo.2020.102900 · Cited by 88
Hedegaard, H. B., Bastian, B. A., Trinidad, J. P., Spencer, M. R., & Warner, M. (2019) · PubMed · Cited by 87
Thomas, S. L., Randle, M., Bestman, A., Pitt, H., Bowe, S. J., Cowlishaw, S., & Daube, M. (2017) · Harm Reduction Journal · doi:10.1186/s12954-017-0173-y · Cited by 76
Centers for Disease Control and Prevention (CDC)
Simon, S. D. (2018) · Springer eBooks · doi:10.1007/978-3-319-32001-4_258-1 · Cited by 65
Mobile supervised consumption services in Rural British Columbia: lessons learned
Mema, S. C., Frosst, G., Bridgeman, J., Drake, H., Dolman, C., Lappalainen, L., & Corneil, T. (2019) · Harm Reduction Journal · doi:10.1186/s12954-018-0273-3 · Cited by 53
Validation and Cross-Reactivity Data for Fentanyl Analogs With the Immunalysis Fentanyl ELISA
Guerrieri, D., Kjellqvist, F., Kronstrand, R., & Gréen, H. (2018) · Journal of Analytical Toxicology · doi:10.1093/jat/bky060 · Cited by 37
Vincent, E. C., Zebelman, A. M., Goodwin, C. L., & Stephens, M. (2006) · The Journal of Family Practice · Cited by 33
Immunoassay-based detection of fentanyl analogs in forensic toxicology
Schackmuth, M., & Kerrigan, S. (2018) · Forensic Toxicology · doi:10.1007/s11419-018-0445-6 · Cited by 19
What common substances can cause false positives on urine screens for drugs of abuse
Vincent, E. C., Zebelman, A. M., & Goodwin, C. L. (2006) · MOspace Institutional Repository (University of Missouri) · Cited by 14
Research works printed but not linked: 2
- Hunt N Ashton M Lenton S Mitcheson L Nelles B A review of the evidence-base for harm reduction approaches to drug use PLoS ONE 2006 3 1 16 30
- BTNX Inc. Rapid Response SIngle Drug Test Strip Product Insert, pp. 3–5
Cited by
Wagner, K. D., Fiuty, P., Page, K. A., Tracy, E. C., Nocera, M., Miller, C. W., Tarhuni, L., & Dasgupta, N. (2023) · Drug and Alcohol Dependence · doi:10.1016/j.drugalcdep.2023.110985 · Cited by 144
Gozdzialski, L., Wallace, B., & Hore, D. (2023) · Harm Reduction Journal · doi:10.1186/s12954-023-00764-3 · Cited by 76
“Abbreviations ATR Attenuated total reflection ATR–IR Attenuated total reflection infrared FT Fourier transform FTIR Fourier transform infrared GC Gas chromatography GC–MS Gas chromatography mass spectrometry IR Infrared LC–MS Liquid chromatography mass spectrometry LOD Limit of detection LSD Lysergic acid diethylamide…”
BackgroundInfluentialResults from a mobile drug checking pilot program using three technologies in Chicago, IL, USA
Karch, L., Tobias, S., Schmidt, C., Doe-Simkins, M., Carter, N., Salisbury-Afshar, E., & Carlberg-Racich, S. (2021) · Drug and Alcohol Dependence · doi:10.1016/j.drugalcdep.2021.108976 · Cited by 51
Friedman, J. R., Bourgois, P. I., Godvin, M., Chavez, A., Pacheco, L., Segovia, L. A., Beletsky, L. A., & Arredondo, J. (2022) · International Journal of Drug Policy · doi:10.1016/j.drugpo.2022.103678 · Cited by 52
Testing the test strips: laboratory performance of fentanyl test strips
Halifax, J. C., Lim, L., Ciccarone, D., & Lynch, K. L. (2024) · Harm Reduction Journal · doi:10.1186/s12954-023-00921-8 · Cited by 45
“The presence of methamphetamine and MDMA in high concentrations has been shown, by only one study, to cause false positives with the BTNX FTS [45], leading some community organizations to advocate for diluting samples to 2 mg/ mL to avoid false positives [47].”
BackgroundResult
Metadata
- Authors
- Lockwood, T.-L. E., Vervoordt, A., & Lieberman, M.
- Affiliations
- University of Notre Dame (US)
- Corresponding author
- Lockwood, Tracy-Lynn E.
- Venue
- Harm Reduction Journal
- Published
- 2021-03-09
- Volume
- 18
- Issue
- 1
- Pages
- 30-30
- ISSN
- 1477-7517 (ISSN-L)
- PMC
- PMC7941948
- OpenAlex
- W3134216738
- Cited by
- 85
- References
- 24
- Citations by year
- 2026: 5 · 2025: 19 · 2024: 24 · 2023: 21 · 2022: 15 · 2021: 1
- FWCI
- 9.94
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/4.0/ (tdm)
- creativecommons.org/licenses/by/4.0/ (vor)
- Locations
- Harm Reduction Journal (publishedVersion, cc-by)
- Research Square (acceptedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- National Center for Advancing Translational Sciences (UL1TR002529)
- Advanced Diagnostics and Therapeutics (Substance Abuse Discovery Fund)
- Topics
- Life Sciences › Pharmacology, Toxicology and Pharmaceutics › Toxicology › Forensic Toxicology and Drug Analysis
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Opioid Use Disorder Treatment
- Health Sciences › Medicine › Epidemiology › HIV, Drug Use, Sexual Risk
- Keywords
- fentanyl test strips, false positives, drug adulterants, cutting agents, illicit stimulants, methamphetamine, MDMA, diphenhydramine, sample preparation, immunoassay interference, harm reduction, drug checking, opioid overdose, heroin
- MeSH terms
- Analgesics, Opioid, Heroin, Drug Contamination, False Positive Reactions, Fentanyl, Humans, Opioid-Related Disorders, Illicit Drugs, Drug Overdose
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.