Validity of physical activity monitors for assessing lower intensity activity in adults
Open accessThe DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Accelerometers can provide accurate estimates of moderate-to-vigorous physical activity (MVPA). However, one of the limitations of these instruments is the inability to capture light activity within an acceptable range of error. The purpose of the present study was to determine the validity of different activity monitors for estimating energy expenditure (EE) of light intensity, semi-structured activities. METHODS: Forty healthy participants wore a SenseWear Pro3 Armband (SWA, v.6.1), the SenseWear Mini, the Actiheart, ActiGraph, and ActivPAL monitors, while being monitored with a portable indirect calorimetry (IC). Participants engaged in a variety of low intensity activities but no formalized scripts or protocols were used during these periods. RESULTS: The Mini and SWA overestimated total EE on average by 1.0% and 4.0%, respectively, while the AH, the GT3X, and the AP underestimated total EE on average by 7.8%, 25.5%, and 22.2%, respectively. The pattern-recognition monitors yielded non-significant differences in EE estimates during the semi-structured period (p = 0.66, p = 0.27, and p = 0.21 for the Mini, SWA, and AH, respectively). CONCLUSIONS: The SenseWear Mini provided more accurate estimates of EE during light to moderate intensity semi-structured activities compared to other activity monitors. This monitor should be considered when there is interest in tracking low intensity activities in groups of individuals.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measuring agreement in method comparison studies
Bland, J. M., & Altman, D. G. (1999) · Statistical Methods in Medical Research · doi:10.1177/096228029900800204 · Cited by 9,619 · cited 3×
“Future research should focus on assessing lower intensity activities using the newly developed techniques to improve MET estimates of accelerometrybased activity monitors (i.e., artificial neural networking and Hidden Markov Modeling), making direct comparisons to multi-sensor activity monitors.”
BackgroundMethodMeasuring agreement in method comparison studies
Bland, J. M., & Altman, D. G. (1999) · Statistical Methods in Medical Research · doi:10.1191/096228099673819272 · Cited by 9,619
Physical Activity in the United States Measured by Accelerometer
TROIANO, R. P., BERRIGAN, D., DODD, K. W., MÂSSE, L. C., TILERT, T., & MCDOWELL, M. (2008) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31815a51b3 · Cited by 7,638 · cited 1×
“It has been recently utilized in a subsample of the National Health and Nutrition Examination Survey (NHANES) to provide objective estimates of physical activity [15].”
MethodCalibration of the Computer Science and Applications, Inc. accelerometer
FREEDSON, P. S., MELANSON, E., & SIRARD, J. (1998) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199805000-00021 · Cited by 3,825
A new predictive equation for resting energy expenditure in healthy individuals
Mifflin, M., St Jeor, S., Hill, L., Scott, B., Daugherty, S., & Koh, Y. (1990) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/51.2.241 · Cited by 2,544 · cited 1×
“In addition, REE values were estimated for each participant using the REE Mifflin predictive equation for adults [21].”
MethodHealy, G. N., Dunstan, D. W., Salmon, J., Cerin, E., Shaw, J. E., Zimmet, P. Z., & Owen, N. (2008) · Diabetes Care · doi:10.2337/dc07-2046 · Cited by 1,465
Role of Nonexercise Activity Thermogenesis in Resistance to Fat Gain in Humans
Levine, J. A., Eberhardt, N. L., & Jensen, M. D. (1999) · Science · doi:10.1126/science.283.5399.212 · Cited by 997 · cited 1×
“Studies have also demonstrated health benefits associated with the accumulation of light intensity activity [3-5].”
BackgroundThe Technology of Accelerometry-Based Activity Monitors: Current and Future
CHEN, K. Y., & BASSETT, D. R. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185571.49104.82 · Cited by 996
Compher, C., Frankenfield, D., Keim, N., & Roth-Yousey, L. (2006) · Journal of the American Dietetic Association · doi:10.1016/j.jada.2006.02.009 · Cited by 923 · cited 1×
“Additional resting metabolic rate (RMR) measurements were performed in a subsample of participants (24/40 participants) using the same metabolic analyzer, after a 10-hour fast, during the morning of a different scheduled day, and following previously published guidelines [20].”
MethodHealy, G. N., Dunstan, D. W., Salmon, J., Cerin, E., Shaw, J. E., Zimmet, P. Z., & Owen, N. (2007) · Diabetes Care · doi:10.2337/dc07-0114 · Cited by 627
Cited by
Brage, S., Westgate, K., Franks, P. W., Stegle, O., Wright, A., Ekelund, U., & Wareham, N. J. (2015) · PLOS ONE · doi:10.1371/journal.pone.0137206 · Cited by 151
“In particular, combining HR and ACC by branched equation modelling may be advantageous for estimating PAEE of structured common daily activities [13–15], unstructured activities [16,17], and a mixture of structured and unstructured activities performed in a whole-body calorimeter over a full day [18].”
MethodChowdhury, E. A., Western, M. J., Nightingale, T. E., Peacock, O. J., & Thompson, D. (2017) · PLOS ONE · doi:10.1371/journal.pone.0171720 · Cited by 118
“Previous research has shown that BodyMedia SenseWear accurately measures energy expenditure relative to criterion measures [11,20,21] and has been used to quantify physical activity and energy expenditure in experimental trials [37,38].”
MethodValidating Accelerometry as a Measure of Physical Activity and Energy Expenditure in Chronic Stroke
Serra, M. C., Balraj, E., DiSanzo, B. L., Ivey, F. M., Hafer-Macko, C. E., Treuth, M. S., & Ryan, A. S. (2017) · Topics in Stroke Rehabilitation · doi:10.1080/10749357.2016.1183866 · Cited by 46
Feehan, L. M., Goldsmith, C. H., Leung, A. Y. F., & Li, L. C. (2016) · Physiotherapy Canada · doi:10.3138/ptc.2015-12 · Cited by 20
Metadata
- Authors
- Calabr, M. A. S., Lee, J.-M., Saint-Maurice, P. F., Yoo, H., & Welk, G. J.
- Venue
- International Journal of Behavioral Nutrition and Physical Activity
- Published
- 2014-09-28
- Volume
- 11
- Issue
- 1
- Pages
- 119-119
- ISSN
- 1479-5868 (ISSN-L)
- OpenAlex
- W2117993525
- Cited by
- 93
- References
- 13
- FWCI
- 7.19
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Validity of physical activity monitors for assessing lower intensity activity in adults. https://app.cochat.ai/papers/10.1186/s12966-014-0119-7
- The paper
- Calabr, M. A. S., Lee, J.-M., Saint-Maurice, P. F., Yoo, H., & Welk, G. J. (2014). Validity of physical activity monitors for assessing lower intensity activity in adults. International Journal of Behavioral Nutrition and Physical Activity. https://doi.org/10.1186/s12966-014-0119-7
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.