Systematic comparative validation of self-report measures of sedentary time against an objective measure of postural sitting (activPAL)
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Sedentary behaviour is a public health concern that requires surveillance and epidemiological research. For such large scale studies, self-report tools are a pragmatic measurement solution. A large number of self-report tools are currently in use, but few have been validated against an objective measure of sedentary time and there is no comparative information between tools to guide choice or to enable comparison between studies. The aim of this study was to provide a systematic comparison, generalisable to all tools, of the validity of self-report measures of sedentary time against a gold standard sedentary time objective monitor. METHODS: Cross sectional data from three cohorts (N = 700) were used in this validation study. Eighteen self-report measures of sedentary time, based on the TAxonomy of Self-report SB Tools (TASST) framework, were compared against an objective measure of postural sitting (activPAL) to provide information, generalizable to all existing tools, on agreement and precision using Bland-Altman statistics, on criterion validity using Pearson correlation, and on data loss. RESULTS: All self-report measures showed poor accuracy compared with the objective measure of sedentary time, with very wide limits of agreement and poor precision (random error > 2.5 h). Most tools under-reported total sedentary time and demonstrated low correlations with objective data. The type of assessment used by the tool, whether direct, proxy, or a composite measure, influenced the measurement characteristics. Proxy measures (TV time) and single item direct measures using a visual analogue scale to assess the proportion of the day spent sitting, showed the best combination of precision and data loss. The recall period (e.g. previous week) had little influence on measurement characteristics. CONCLUSION: Self-report measures of sedentary time result in large bias, poor precision and low correlation with an objective measure of sedentary time. Choice of tool depends on the research context, design and question. Choice can be guided by this systematic comparative validation and, in the case of population surveillance, it recommends to use a visual analog scale and a 7 day recall period. Comparison between studies and improving population estimates of average sedentary time, is possible with the comparative correction factors provided.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biswas, A., Oh, P. I., Faulkner, G. E., Bajaj, R. R., Silver, M. A., Mitchell, M. S., & Alter, D. A. (2015) · Annals of Internal Medicine · doi:10.7326/m14-1651 · Cited by 2,726
Letter to the Editor: Standardized use of the terms “sedentary” and “sedentary behaviours”
Networ, S. B. R. (2012) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/h2012-024 · Cited by 1,873
Sedentary time and cardio-metabolic biomarkers in US adults: NHANES 2003–06
Healy, G. N., Matthews, C. E., Dunstan, D. W., Winkler, E. A. H., & Owen, N. (2011) · European Heart Journal · doi:10.1093/eurheartj/ehq451 · Cited by 1,368 · cited 1×
“From studies using objective monitors, it is possible that the pattern in which ST is accumulated may influence health as well as the total time spent sedentary [19, 20].”
BackgroundMeasurement of Adults' Sedentary Time in Population-Based Studies
Healy, G. N., Clark, B. K., Winkler, E. A. H., Gardiner, P. A., Brown, W. J., & Matthews, C. E. (2011) · American Journal of Preventive Medicine · doi:10.1016/j.amepre.2011.05.005 · Cited by 628
Considerations when using the activPAL monitor in field-based research with adult populations
Edwardson, C. L., Winkler, E. A. H., Bodicoat, D. H., Yates, T., Davies, M. J., Dunstan, D. W., & Healy, G. N. (2017) · Journal of Sport and Health Science · doi:10.1016/j.jshs.2016.02.002 · Cited by 502 · cited 1×
“While these are generally considered reliable and valid [23], they are not free of bias and error.”
BackgroundMeta‐analysis of the relationship between breaks in sedentary behavior and cardiometabolic health
Chastin, S. F. M., Egerton, T., Leask, C., & Stamatakis, E. (2015) · Obesity · doi:10.1002/oby.21180 · Cited by 363 · cited 1×
“From studies using objective monitors, it is possible that the pattern in which ST is accumulated may influence health as well as the total time spent sedentary [19, 20].”
BackgroundSelf-citationMethods for objective measure, quantification and analysis of sedentary behaviour and inactivity
Chastin, S. F. M., & Granat, M. H. (2010) · Gait & Posture · doi:10.1016/j.gaitpost.2009.09.002 · Cited by 323
Self-citation
Cited by
Prince, S. A., Cardilli, L., Reed, J. L., Saunders, T. J., Kite, C., Douillette, K., Fournier, K., & Buckley, J. P. (2020) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-020-00938-3 · Cited by 520
Sedentary Behavior and Cardiovascular Disease in Older Women: The OPACH Study
Bellettiere, J., LaMonte, M. J., Evenson, K. R., Rillamas-Sun, E., Kerr, J., Lee, I.-M., Di, C., Rosenberg, D. E., Stefanick, M. L., Buchner, D. M., et al. (2019) · Circulation · doi:10.1161/circulationaha.118.035312 · Cited by 252
Strain, T., Milton, K., Dall, P., Standage, M., & Mutrie, N. (2020) · British Journal of Sports Medicine · doi:10.1136/bjsports-2018-100355 · Cited by 36
Self-citationOpdal, I. M., Morseth, B., Handegård, B.-H., Lillevoll, K. R., Nilsen, W., Nielsen, C., Furberg, A.-S., Rosenbaum, S., & Rognmo, K. (2020) · BMJ Open · doi:10.1136/bmjopen-2019-035549 · Cited by 20
Metadata
- Authors
- on behalf of the Seniors USP team, Chastin, S. F. M., Dontje, M. L., Skelton, D. A., Čukić, I., Shaw, R. J., Gill, J. M. R., Greig, C. A., Gale, C. R., Deary, I. J., Der, G., & Dall, P. M.
- Venue
- International Journal of Behavioral Nutrition and Physical Activity
- Published
- 2018-02-26
- Volume
- 15
- Issue
- 1
- Pages
- 21-21
- ISSN
- 1479-5868 (ISSN-L)
- OpenAlex
- W2792341953
- Cited by
- 152
- References
- 7
- FWCI
- 10.54
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Systematic comparative validation of self-report measures of sedentary time against an objective measure of postural sitting (activPAL). https://app.cochat.ai/papers/10.1186/s12966-018-0652-x
- The paper
- on behalf of the Seniors USP team, Chastin, S. F. M., Dontje, M. L., Skelton, D. A., Čukić, I., Shaw, R. J., Gill, J. M. R., Greig, C. A., Gale, C. R., Deary, I. J., Der, G., & Dall, P. M. (2018). Systematic comparative validation of self-report measures of sedentary time against an objective measure of postural sitting (activPAL). International Journal of Behavioral Nutrition and Physical Activity. https://doi.org/10.1186/s12966-018-0652-x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.