Automated quality control in image segmentation: application to the UK Biobank cardiovascular magnetic resonance imaging study
Open accessThe DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
BACKGROUND: The trend towards large-scale studies including population imaging poses new challenges in terms of quality control (QC). This is a particular issue when automatic processing tools such as image segmentation methods are employed to derive quantitative measures or biomarkers for further analyses. Manual inspection and visual QC of each segmentation result is not feasible at large scale. However, it is important to be able to automatically detect when a segmentation method fails in order to avoid inclusion of wrong measurements into subsequent analyses which could otherwise lead to incorrect conclusions. METHODS: To overcome this challenge, we explore an approach for predicting segmentation quality based on Reverse Classification Accuracy, which enables us to discriminate between successful and failed segmentations on a per-cases basis. We validate this approach on a new, large-scale manually-annotated set of 4800 cardiovascular magnetic resonance (CMR) scans. We then apply our method to a large cohort of 7250 CMR on which we have performed manual QC. RESULTS: We report results used for predicting segmentation quality metrics including Dice Similarity Coefficient (DSC) and surface-distance measures. As initial validation, we present data for 400 scans demonstrating 99% accuracy for classifying low and high quality segmentations using the predicted DSC scores. As further validation we show high correlation between real and predicted scores and 95% classification accuracy on 4800 scans for which manual segmentations were available. We mimic real-world application of the method on 7250 CMR where we show good agreement between predicted quality metrics and manual visual QC scores. CONCLUSIONS: We show that Reverse classification accuracy has the potential for accurate and fully automatic segmentation QC on a per-case basis in the context of large-scale population imaging as in the UK Biobank Imaging Study.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sudlow, C., Gallacher, J., Allen, N., Beral, V., Burton, P., Danesh, J., Downey, P., Elliott, P., Green, J., Landray, M., et al. (2015) · PLOS Medicine · doi:10.1371/journal.pmed.1001779 · Cited by 12,728 · cited 4×
“6 RCA Application on 7250 Cardiac MRI segmentations of UKBB Imaging Study.”
BackgroundInfluentialSelf-citationGeneralized Overlap Measures for Evaluation and Validation in Medical Image Analysis
Crum, W. R., Camara, O., & Hill, D. L. G. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.880587 · Cited by 776 · cited 1×
“Popular metrics include volumetric overlap [5], surface distances or other statistical measures [6].”
BackgroundAutomated cardiovascular magnetic resonance image analysis with fully convolutional networks
Bai, W., Sinclair, M., Tarroni, G., Oktay, O., Rajchl, M., Vaillant, G., Lee, A. M., Aung, N., Lukaschuk, E., Sanghvi, M. M., et al. (2018) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-018-0471-x · Cited by 773
Self-citationUK Biobank's cardiovascular magnetic resonance protocol
Petersen, S. E., Matthews, P. M., Francis, J. M., Robson, M. D., Zemrak, F., Boubertakh, R., Young, A. A., Hudson, S., Weale, P., Garratt, S., et al. (2016) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-016-0227-4 · Cited by 481
Self-citationReverse Classification Accuracy: Predicting Segmentation Performance in the Absence of Ground Truth
Valindria, V. V., Lavdas, I., Bai, W., Kamnitsas, K., Aboagye, E. O., Rockall, A. G., Rueckert, D., & Glocker, B. (2017) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2017.2665165 · Cited by 152
Self-citationCross Validation Framework to Choose amongst Models and Datasets for Transfer Learning
Zhong, E., Fan, W., Yang, Q., Verscheure, O., & Ren, J. (2010) · Lecture Notes in Computer Science · doi:10.1007/978-3-642-15939-8_35 · Cited by 132
Encoding atlases by randomized classification forests for efficient multi-atlas label propagation
Zikic, D., Glocker, B., & Criminisi, A. (2014) · Medical Image Analysis · doi:10.1016/j.media.2014.06.010 · Cited by 81 · cited 1×
“The original work on RCA [11] explored a variety of possible classifiers that could be trained on a single testimage and its segmentation including Atlas Forests (AF) [12] and CNNs.”
BackgroundSelf-citationAutomatic Quality Control of Cardiac MRI Segmentation in Large-Scale Population Imaging
Robinson, R., Valindria, V. V., Bai, W., Suzuki, H., Matthews, P. M., Page, C., Rueckert, D., & Glocker, B. (2017) · Lecture Notes in Computer Science · doi:10.1007/978-3-319-66182-7_82 · Cited by 37 · cited 1×
“segmentation t k s . To apply RCA, all reference images R i are rst registered to tk i by performing a rigid registration in the form of a centre of mass (CoM) alignment. Initial versions of our work [13] used landmark registration [14] at this stage, but we now opt for CoM alignment to reduce computational cost. We t…”
MethodSelf-citationReverse testing: an efficient framework to select amongst classifiers under sample selection bias
Fan, W., & Davidson, I. (2006) · Proceedings of the 12th ACM SIGKDD international conference on Knowledge discovery and data mining · doi:10.1145/1150402.1150422 · Cited by 35
Cited by
Deep Learning for Cardiac Image Segmentation: A Review
Chen, C., Qin, C., Qiu, H., Tarroni, G., Duan, J., Bai, W., & Rueckert, D. (2020) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2020.00025 · Cited by 869
Self-citationMedical image segmentation automatic quality control: A multi-dimensional approach
Fournel, J., Bartoli, A., Bendahan, D., Guye, M., Bernard, M., Rauseo, E., Khanji, M. Y., Petersen, S. E., Jacquier, A., & Ghattas, B. (2021) · Medical Image Analysis · doi:10.1016/j.media.2021.102213 · Cited by 45
Self-citationEfficient Model Monitoring for Quality Control in Cardiac Image Segmentation
Galati, F., & Zuluaga, M. A. (2021) · Lecture Notes in Computer Science · doi:10.1007/978-3-030-78710-3_11 · Cited by 15
Specktor-Fadida, B., Ben-Sira, L., Ben-Bashat, D., & Joskowicz, L. (2024) · arXiv · Cited by 9
QCResUNet: Joint Subject-Level and Voxel-Level Prediction of Segmentation Quality
Qiu, P., Chakrabarty, S., Nguyen, P., Ghosh, S. S., & Sotiras, A. (2023) · Lecture Notes in Computer Science · doi:10.1007/978-3-031-43901-8_17 · Cited by 3
Metadata
- Authors
- Robinson, R., Valindria, V. V., Bai, W., Oktay, O., Kainz, B., Suzuki, H., Sanghvi, M. M., Aung, N., Paiva, J. M., Zemrak, F., Fung, K., Lukaschuk, E., Lee, A. M., Carapella, V., Kim, Y. J., Piechnik, S. K., Neubauer, S., Petersen, S. E., Page, C., Matthews, P. M., Rueckert, D., & Glocker, B.
- Venue
- Journal of Cardiovascular Magnetic Resonance
- Publisher
- Elsevier BV
- Published
- 2019-01
- Volume
- 21
- Issue
- 1
- Pages
- 18
- ISSN
- 1097-6647 (ISSN-L)
- OpenAlex
- W2930326546
- Cited by
- 120
- References
- 9
- FWCI
- 8.27
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Automated quality control in image segmentation: application to the UK Biobank cardiovascular magnetic resonance imaging study. https://app.cochat.ai/papers/10.1186/s12968-019-0523-x
- The paper
- Robinson, R., Valindria, V. V., Bai, W., Oktay, O., Kainz, B., Suzuki, H., Sanghvi, M. M., Aung, N., Paiva, J. M., Zemrak, F., Fung, K., Lukaschuk, E., Lee, A. M., Carapella, V., Kim, Y. J., Piechnik, S. K., Neubauer, S., Petersen, S. E., Page, C., . . . Glocker, B. (2019). Automated quality control in image segmentation: application to the UK Biobank cardiovascular magnetic resonance imaging study. Journal of Cardiovascular Magnetic Resonance. https://doi.org/10.1186/s12968-019-0523-x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.