Physiological and kinematic effects of a soft exosuit on arm movements
Open accessThe DOI matches its Crossref record; 63 of the 63 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Soft wearable robots (exosuits), being lightweight, ergonomic and low power-demanding, are attractive for a variety of applications, ranging from strength augmentation in industrial scenarios, to medical assistance for people with motor impairments. Understanding how these devices affect the physiology and mechanics of human movements is fundamental for quantifying their benefits and drawbacks, assessing their suitability for different applications and guiding a continuous design refinement. METHODS: We present a novel wearable exosuit for assistance/augmentation of the elbow and introduce a controller that compensates for gravitational forces acting on the limb while allowing the suit to cooperatively move with its wearer. Eight healthy subjects wore the exosuit and performed elbow movements in two conditions: with assistance from the device (powered) and without assistance (unpowered). The test included a dynamic task, to evaluate the impact of the assistance on the kinematics and dynamics of human movement, and an isometric task, to assess its influence on the onset of muscular fatigue. RESULTS: Powered movements showed a low but significant degradation in accuracy and smoothness when compared to the unpowered ones. The degradation in kinematics was accompanied by an average reduction of 59.20±5.58% (mean ± standard error) of the biological torque and 64.8±7.66% drop in muscular effort when the exosuit assisted its wearer. Furthermore, an analysis of the electromyographic signals of the biceps brachii during the isometric task revealed that the exosuit delays the onset of muscular fatigue. CONCLUSIONS: The study examined the effects of an exosuit on the characteristics of human movements. The suit supports most of the power needed to move and reduces the effort that the subject needs to exert to counteract gravity in a static posture, delaying the onset of muscular fatigue. We interpret the decline in kinematic performance as a technical limitation of the current device. This work suggests that a powered exosuit can be a good candidate for industrial and clinical applications, where task efficiency and hardware transparency are paramount.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Development of recommendations for SEMG sensors and sensor placement procedures
Hermens, H. J., Freriks, B., Disselhorst-Klug, C., & Rau, G. (2000) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(00)00027-4 · Cited by 7,213
The coordination of arm movements: an experimentally confirmed mathematical model
Flash, T., & Hogan, N. (1985) · The Journal of Neuroscience · doi:10.1523/jneurosci.05-07-01688.1985 · Cited by 4,395
Impedance Control: An Approach to Manipulation
Hogan, N. (1984) · 1984 American Control Conference · doi:10.23919/acc.1984.4788393 · Cited by 2,929 · cited 2×
“This is because by imposing the relation between force and velocity, unlike direct force or position control schemes, allows to constrain the power transfer between the device and its user [39].”
Pratt, G. A., & Williamson, M. M. (2002) · Proceedings 1995 IEEE/RSJ International Conference on Intelligent Robots and Systems. Human Robot Interaction and Cooperative Robots · doi:10.1109/iros.1995.525827 · Cited by 2,206 · cited 1×
“While on one hand this series-elasticity is an undesirable property because it lowers transmission efficiency and position-control bandwidth, on the other it introduces well-known advantages in terms of safety and force control accuracy and stability [37].”
Soft robotic glove for combined assistance and at-home rehabilitation
Polygerinos, P., Wang, Z., Galloway, K. C., Wood, R. J., & Walsh, C. J. (2015) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2014.08.014 · Cited by 1,617
Soft Robotics: A Perspective—Current Trends and Prospects for the Future
Majidi, C. (2014) · Soft Robotics · doi:10.1089/soro.2013.0001 · Cited by 1,302
Electromyography: Physiology, Engineering, and Noninvasive Applications
(2004) · Wiley eBooks · doi:10.1002/0471678384 · Cited by 1,151
Control strategies for active lower extremity prosthetics and orthotics: a review
Tucker, M. R., Olivier, J., Pagel, A., Bleuler, H., Bouri, M., Lambercy, O., Millán, J. D. R., Riener, R., Vallery, H., & Gassert, R. (2015) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-12-1 · Cited by 1,047
Human-in-the-loop optimization of exoskeleton assistance during walking
Zhang, J., Fiers, P., Witte, K. A., Jackson, R. W., Poggensee, K. L., Atkeson, C. G., & Collins, S. H. (2017) · Science · doi:10.1126/science.aal5054 · Cited by 1,011
Reducing the energy cost of human walking using an unpowered exoskeleton
Collins, S. H., Wiggin, M. B., & Sawicki, G. S. (2015) · Nature · doi:10.1038/nature14288 · Cited by 967
Esquenazi, A., Talaty, M., Packel, A., & Saulino, M. (2012) · American Journal of Physical Medicine & Rehabilitation · doi:10.1097/phm.0b013e318269d9a3 · Cited by 958
A soft robotic exosuit improves walking in patients after stroke
Awad, L. N., Bae, J., O’Donnell, K., De Rossi, S. M. M., Hendron, K., Sloot, L. H., Kudzia, P., Allen, S., Holt, K. G., Ellis, T. D., et al. (2017) · Science Translational Medicine · doi:10.1126/scitranslmed.aai9084 · Cited by 672
Sampling, noise-reduction and amplitude estimation issues in surface electromyography
Clancy, E. A., Morin, E. L., & Merletti, R. (2002) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(01)00033-5 · Cited by 634 · cited 1×
“The output EMG signal of the Delsys Trigno system (pre-conditioned with a band-pass Butterworth filter between 20 Hz and 450 Hz) was processed to extract its linear average envelope using the procedure suggested in [51]: this included noise filtering, rectification, smoothening using a moving-average filter (0.”
Human-in-the-loop optimization of hip assistance with a soft exosuit during walking
Ding, Y., Kim, M., Kuindersma, S., & Walsh, C. J. (2018) · Science Robotics · doi:10.1126/scirobotics.aar5438 · Cited by 612
On the analysis of movement smoothness
Balasubramanian, S., Melendez-Calderon, A., Roby-Brami, A., & Burdet, E. (2015) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-015-0090-9 · Cited by 575
Autonomous exoskeleton reduces metabolic cost of human walking during load carriage
Mooney, L. M., Rouse, E. J., & Herr, H. M. (2014) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-11-80 · Cited by 461
Assistance magnitude versus metabolic cost reductions for a tethered multiarticular soft exosuit
Quinlivan, B. T., Lee, S., Malcolm, P., Rossi, D. M., Grimmer, M., Siviy, C., Karavas, N., Wagner, D., Asbeck, A., Galiana, I., et al. (2017) · Science Robotics · doi:10.1126/scirobotics.aah4416 · Cited by 370 · cited 1×
“Using this paradigm to provide assistance to the lower limbs has resulted in unprecedented levels of walking economy in healthy subjects [26] and improved symmetry and efficiency of mobility in stroke patients [27].”
Having a body versus moving your body: Neural signatures of agency and body-ownership
Tsakiris, M., Longo, M. R., & Haggard, P. (2010) · Neuropsychologia · doi:10.1016/j.neuropsychologia.2010.05.021 · Cited by 358
Development and Control of a ‘Soft-Actuated’ Exoskeleton for Use in Physiotherapy and Training
Tsagarakis, N. G., & Caldwell, D. G. (2003) · Autonomous Robots · doi:10.1023/a:1024484615192 · Cited by 335
Pilot study of Lokomat versus manual-assisted treadmill training for locomotor recovery post-stroke
Westlake, K. P., & Patten, C. (2009) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-6-18 · Cited by 330
A Review of Algorithms for Compliant Control of Stiff and Fixed-Compliance Robots
Calanca, A., Muradore, R., & Fiorini, P. (2016) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2015.2465849 · Cited by 320
Learning to walk with a robotic ankle exoskeleton
Gordon, K. E., & Ferris, D. P. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2006.12.006 · Cited by 318 · cited 1×
“Previous studies confirm that the initial disruption of natural kinematics of movement, often seen when one first wears an assistive robotic apparatus, progressively diminishes as the subject learns to use the device [65].”
Robertson, D. G. E. (2014) · Research Methods in Biomechanics · doi:10.5040/9781492595809.ch-003 · Cited by 315
Yap, H. K., Lim, J. H., Nasrallah, F., Goh, J. C. H., & Yeow, R. C. H. (2015) · 2015 IEEE International Conference on Robotics and Automation (ICRA) · doi:10.1109/icra.2015.7139889 · Cited by 299
Yap, H. K., Khin, P. M., Koh, T. H., Sun, Y., Liang, X., Lim, J. H., & Yeow, C.-H. (2017) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2017.2669366 · Cited by 277
Self-Aligning Exoskeleton Axes Through Decoupling of Joint Rotations and Translations
Stienen, A. H. A., Hekman, E. E. G., van der Helm, F. C. T., & van der Kooij, H. (2009) · IEEE Transactions on Robotics · doi:10.1109/tro.2009.2019147 · Cited by 249
Biologically-inspired soft exosuit
Asbeck, A. T., Dyer, R. J., Larusson, A. F., & Walsh, C. J. (2013) · 2013 IEEE 13th International Conference on Rehabilitation Robotics (ICORR) · doi:10.1109/icorr.2013.6650455 · Cited by 240
Biomechanical and Physiological Evaluation of Multi-Joint Assistance With Soft Exosuits
Ding, Y., Galiana, I., Asbeck, A. T., De Rossi, S. M. M., Bae, J., Santos, T. R. T., de Araujo, V. L., Lee, S., Holt, K. G., & Walsh, C. (2017) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2016.2523250 · Cited by 217
Contribution of Feedback and Feedforward Strategies to Locomotor Adaptations
Lam, T., Anderschitz, M., & Dietz, V. (2006) · Journal of Neurophysiology · doi:10.1152/jn.00473.2005 · Cited by 204
Schmidt, K., Duarte, J. E., Grimmer, M., Sancho-Puchades, A., Wei, H., Easthope, C. S., & Riener, R. (2017) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2017.00057 · Cited by 202 · cited 1×
“Similar principles were used to provide active support to hip and knee extension, reducing activation of the gluteus maximus in sit-to-stand and stand-to-sit transitions [28].”
MethodA soft wearable robot for the shoulder: Design, characterization, and preliminary testing
O'Neill, C. T., Phipps, N. S., Cappello, L., Paganoni, S., & Walsh, C. J. (2017) · 2017 International Conference on Rehabilitation Robotics (ICORR) · doi:10.1109/icorr.2017.8009488 · Cited by 183 · cited 2×
“The latter paradigm was probably among the first to be proposed [19] and has been explored to assist stroke patients during walking [20], to increase shoulder mobility in subjects with neuromuscular conditions [21], to help elbow movements [22] and for rehabilitation purposes to train and aid grasping [23–25].”
Potvin, J. R., & Bent, L. R. (1997) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(96)00025-9 · Cited by 182 · cited 1×
“Although fatiguing protocols often involve higher loads and isometric contractions until voluntary exhaustion [48], our suit was not designed to transmit heavy weights to the human body.”
Exoskeletons for human power augmentation
Kazerooni, H. (2005) · 2005 IEEE/RSJ International Conference on Intelligent Robots and Systems · doi:10.1109/iros.2005.1545451 · Cited by 181 · cited 1×
“Wearable robotic technology has been successful in augmenting human strength during locomotion [3], reducing the metabolic cost of human walking [4, 5], restoring ambulatory capabilities to paraplegic patients [6], assisting in rehabilitating stroke”
Constrained and Unconstrained Movements Involve Different Control Strategies
Desmurget, M., Jordan, M., Prablanc, C., & Jeannerod, M. (1997) · Journal of Neurophysiology · doi:10.1152/jn.1997.77.3.1644 · Cited by 181
Wen, W., Yamashita, A., & Asama, H. (2015) · Consciousness and Cognition · doi:10.1016/j.concog.2015.06.004 · Cited by 172 · cited 1×
“Previous work has shown that a longer interval between actions and their effects is associated with a lower sense of agency [60].”
BackgroundPirondini, E., Coscia, M., Marcheschi, S., Roas, G., Salsedo, F., Frisoli, A., Bergamasco, M., & Micera, S. (2016) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-016-0117-x · Cited by 169 · cited 2×
“Unfortunately, no investigation performing such assessment on soft exosuits exists in literature, but our results echo the findings from Jarassé [63] and Pirondini [64], reporting an increase in movement jerk and number of peaks, respectively, when subjects were assisted by a rigid exoskeleton.”
ResultSelf-citationSoft exosuit for hip assistance
Asbeck, A. T., Schmidt, K., & Walsh, C. J. (2015) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2014.09.025 · Cited by 167
Positive effects of robotic exoskeleton training of upper limb reaching movements after stroke
Frisoli, A., Procopio, C., Chisari, C., Creatini, I., Bonfiglio, L., Bergamasco, M., Rossi, B., & Carboncini, M. C. (2012) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-9-36 · Cited by 163
Self-citationThe embodiment of assistive devices—from wheelchair to exoskeleton
Pazzaglia, M., & Molinari, M. (2015) · Physics of Life Reviews · doi:10.1016/j.plrev.2015.11.006 · Cited by 153
Christiaen, E., Goossens, M.-G., Descamps, B., Boon, P., Raedt, R., & Vanhove, C. (2017) · Frontiers in Neuroscience · doi:10.3389/conf.fnins.2017.94.00011 · Cited by 152
Mosher, R. S. (1967) · SAE technical papers on CD-ROM/SAE technical paper series · doi:10.4271/670088 · Cited by 142
Late motor processing in low-impedance robots: impedance control of series-elastic actuators
Pratt, G. A., Willisson, P., Bolton, C., & Hofman, A. (2004) · Proceedings of the ... American Control Conference/Proceedings of the American Control Conference · doi:10.23919/acc.2004.1384410 · Cited by 128 · cited 1×
“This approach, known as collocated admittance control [38], has been shown to robustly deal with force disturbances such as stiction and backlash [40], abundant in the soft exosuit.”
PID admittance control for an upper limb exoskeleton
Yu, W., Rosén, J., & Li, X. (2011) · Proceedings of the ... American Control Conference/Proceedings of the American Control Conference · doi:10.1109/acc.2011.5991147 · Cited by 125 · cited 2×
“The admittance can assume the form of a PID controller [41]:”
MethodDevelopment of a biomechanical energy harvester
Li, Q., Naing, V., & Donelan, J. M. (2009) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-6-22 · Cited by 121
Xiloyannis, M., Cappello, L., Dinh, B. K., Antuvan, C. W., & Masia, L. (2017) · Journal of Rehabilitation and Assistive Technologies Engineering · doi:10.1177/2055668316680315 · Cited by 109
Self-citationAdaptive backlash compensation in upper limb soft wearable exoskeletons
Dinh, B. K., Xiloyannis, M., Cappello, L., Antuvan, C. W., Yen, S., & Masia, L. (2017) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2017.03.012 · Cited by 103
Self-citationBeing like everybody else: the personal meanings of being a prosthesis user
Murray, C. D. (2008) · Disability and Rehabilitation · doi:10.1080/09638280802240290 · Cited by 102
Buckley, M., Yardley, A., Johnson, G., & Cams, D. A. (1996) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1243/pime_proc_1996_210_420_02 · Cited by 100
Design and embedded control of a soft elbow exosuit
Chiaradia, D., Xiloyannis, M., Antuvan, C. W., Frisoli, A., & Masia, L. (2018) · IEEE International Conference on Soft Robotics (RoboSoft) · doi:10.1109/robosoft.2018.8405386 · Cited by 100 · cited 2×
“, where a soft exosuit for the elbow was shown to reduce the activation of the biceps brachii muscle in dynamic movements [31], and by Khanh et al.”
Self-citationBio-inspired upper limb soft exoskeleton to reduce stroke-induced complications
Li, N., Yang, T., Yu, P., Chang, J., Zhao, L., Zhao, X., Elhajj, I. H., Xi, N., & Liu, L. (2018) · Bioinspiration & Biomimetics · doi:10.1088/1748-3190/aad8d4 · Cited by 92 · cited 1×
“Li and colleagues [56] use a paradigm similar to the one presented here to assist healthy subjects and stroke patients in flexing the shoulder and elbow.”
Hierarchical Cascade Controller for Assistance Modulation in a Soft Wearable Arm Exoskeleton
Dinh, B. K., Xiloyannis, M., Antuvan, C. W., Cappello, L., & Masia, L. (2017) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2017.2668473 · Cited by 88
Self-citationA Soft-Inflatable Exosuit for Knee Rehabilitation: Assisting Swing Phase During Walking
Sridar, S., Qiao, Z., Muthukrishnan, N., Zhang, W., & Polygerinos, P. (2018) · Frontiers in Robotics and AI · doi:10.3389/frobt.2018.00044 · Cited by 84
Design of a Soft Robotic Elbow Sleeve with Passive and Intent-Controlled Actuation
Koh, T. H., Cheng, N., Yap, H. K., & Yeow, C. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00597 · Cited by 82 · cited 1×
“The latter paradigm was probably among the first to be proposed [19] and has been explored to assist stroke patients during walking [20], to increase shoulder mobility in subjects with neuromuscular conditions [21], to help elbow movements [22] and for rehabilitation purposes to train and aid grasping [23–25].”
Park, D., & Cho, K. (2017) · PLoS ONE · doi:10.1371/journal.pone.0173730 · Cited by 78 · cited 3×
“A similar finding is described in [30], where a cable-driven suit for the shoulder is shown to reduce the fatigue in the anterior and medial deltoid of five healthy subjects.”
BackgroundInfluentialJarrassé, N., Tagliabue, M., Robertson, J., Maiza, A., Crocher, V., Roby-Brami, A., & Morel, G. (2010) · IEEE transactions on neural systems and rehabilitation engineering · doi:10.1109/tnsre.2010.2056388 · Cited by 73 · cited 1×
“Unfortunately, no investigation performing such assessment on soft exosuits exists in literature, but our results echo the findings from Jarassé [63] and Pirondini [64], reporting an increase in movement jerk and number of peaks, respectively, when subjects were assisted by a rigid exoskeleton.”
Development of muscle suit for upper limb
Kobayashi, H., & Hiramatsu, K. (2004) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.2004.1307433 · Cited by 61 · cited 1×
“The latter paradigm was probably among the first to be proposed [19] and has been explored to assist stroke patients during walking [20], to increase shoulder mobility in subjects with neuromuscular conditions [21], to help elbow movements [22] and for rehabilitation purposes to train and aid grasping [23–25].”
Retraining of Human Gait - Are Lightweight Cable-Driven Leg Exoskeleton Designs Effective?
Jin, X. H., Prado, A., & Agrawal, S. K. (2018) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2018.2815656 · Cited by 59
B, T. J. S. A. (1998) · Nature · doi:10.1038/29406 · Cited by 59
The atomic fortress that time forgot [plutonium production plant
Guizzo, E. (2005) · IEEE Spectrum · doi:10.1109/mspec.2005.1413730 · Cited by 52
Force Transfer Characterization of a Soft Exosuit for Gait Assistance
Quinlivan, B., Asbeck, A. T., Wagner, D. A., Ranzani, T., Russo, S., & Walsh, C. J. (2015) · ASME International Design Engineering Technical Conferences and Computers and Information in Engineering Conference (IDETC/CIE) · doi:10.1115/detc2015-47871 · Cited by 46 · cited 1×
“Figure 1d shows a characterisation of the exosuit’s stiffness on a rigid mannequin using the methodology described in [36], consisting in commanding the motor to apply a force of 100N on the flexing/extending tendon andmeasuring its displacement.”
Wrist Proprioception: Amplitude or Position Coding?
Marini, F., Squeri, V., Morasso, P., & Masia, L. (2016) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2016.00013 · Cited by 27
Self-citationAnalysis of human-exoskeleton interactions: an elbow flexion/extension case study
Bastide, S., Vignais, N., Geffard, F., & Berret, B. (2017) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2017.1382835 · Cited by 7
(1964) · PubMed
Cited by
Textile Technology for Soft Robotic and Autonomous Garments
Sanchez, V., Walsh, C. J., & Wood, R. J. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202008278 · Cited by 292
Soft Robotic Suits: State of the Art, Core Technologies, and Open Challenges
Xiloyannis, M., Alicea, R., Georgarakis, A.-M., Haufe, F. L., Wolf, P., Masia, L., & Riener, R. (2022) · IEEE Transactions on Robotics · doi:10.1109/tro.2021.3084466 · Cited by 225
“c), with an on-board, mobile actuation scheme [88] and shown to reduce muscular activity and delay the onset of fatigue in healthy users [75].”
BackgroundMethodInfluentialSelf-citationSoft, Wearable Robotics and Haptics: Technologies, Trends, and Emerging Applications
Zhu, M., Biswas, S., Dinulescu, S. I., Kastor, N., Hawkes, E. W., & Visell, Y. (2022) · Proceedings of the IEEE · doi:10.1109/jproc.2021.3140049 · Cited by 172
Metadata
- Authors
- Xiloyannis, M., Chiaradia, D., Frisoli, A., & Masia, L.
- Venue
- Journal of NeuroEngineering and Rehabilitation
- Published
- 2019-02-22
- Volume
- 16
- Issue
- 1
- Pages
- 29-29
- ISSN
- 1743-0003 (ISSN-L)
- OpenAlex
- W2915802974
- Cited by
- 161
- References
- 63
- FWCI
- 6.63
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.