A perfused human blood–brain barrier on-a-chip for high-throughput assessment of barrier function and antibody transport
Open accessThe DOI matches its Crossref record; 74 of the 74 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Receptor-mediated transcytosis is one of the major routes for drug delivery of large molecules into the brain. The aim of this study was to develop a novel model of the human blood-brain barrier (BBB) in a high-throughput microfluidic device. This model can be used to assess passage of large biopharmaceuticals, such as therapeutic antibodies, across the BBB. METHODS: The model comprises human cell lines of brain endothelial cells, astrocytes, and pericytes in a two-lane or three-lane microfluidic platform that harbors 96 or 40 chips, respectively, in a 384-well plate format. In each chip, a perfused vessel of brain endothelial cells was grown against an extracellular matrix gel, which was patterned by means of surface tension techniques. Astrocytes and pericytes were added on the other side of the gel to complete the BBB on-a-chip model. Barrier function of the model was studied using fluorescent barrier integrity assays. To test antibody transcytosis, the lumen of the model's endothelial vessel was perfused with an anti-transferrin receptor antibody or with a control antibody. The levels of antibody that penetrated to the basal compartment were quantified using a mesoscale discovery assay. RESULTS: cm/min, respectively). CONCLUSIONS: We demonstrate successful integration of a human BBB microfluidic model in a high-throughput plate-based format that can be used for drug screening purposes. This in vitro model shows sufficient barrier function to study the passage of large molecules and is sensitive to differences in antibody penetration, which could support discovery and engineering of BBB-shuttle technologies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fiji: an open-source platform for biological-image analysis
Schindelin, J., Arganda-Carreras, I., Frise, E., Kaynig, V., Longair, M., Pietzsch, T., Preibisch, S., Rueden, C., Saalfeld, S., Schmid, B., et al. (2012) · Nature Methods · doi:10.1038/nmeth.2019 · Cited by 66,890
Ror2 signaling regulates Golgi structure and transport through IFT20 for tumor invasiveness
Nishita, M., Park, S.-Y., Nishio, T., Kamizaki, K., Wang, Z., Tamada, K., Takumi, T., Hashimoto, R., Otani, H., Pazour, G. J., et al. (2017) · Scientific Reports · doi:10.1038/s41598-016-0028-x · Cited by 15,947
Structure and function of the blood–brain barrier
Abbott, N. J., Patabendige, A. A. K., Dolman, D. E. M., Yusof, S. R., & Begley, D. J. (2010) · Neurobiology of Disease · doi:10.1016/j.nbd.2009.07.030 · Cited by 5,185
Development, maintenance and disruption of the blood-brain barrier
Obermeier, B., Daneman, R., & Ransohoff, R. M. (2013) · Nature Medicine · doi:10.1038/nm.3407 · Cited by 2,452
Self-citationDrug Transport across the Blood–Brain Barrier
Pardridge, W. M. (2012) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2012.126 · Cited by 1,994
Tight junctions of the blood–brain barrier
Wolburg, H., & Lippoldt, A. (2002) · Vascular Pharmacology · doi:10.1016/s1537-1891(02)00200-8 · Cited by 1,183
The Dynamic Response of Vascular Endothelial Cells to Fluid Shear Stress
Dewey, C. F., Bussolari, S. R., Gimbrone, M. A., & Davies, P. F. (1981) · Journal of Biomechanical Engineering · doi:10.1115/1.3138276 · Cited by 1,136
Transferrin receptor on endothelium of brain capillaries
Jefferies, W. A., Brandon, M. R., Hunt, S. V., Williams, A. F., Gatter, K. C., & Mason, D. Y. (1984) · Nature · doi:10.1038/312162a0 · Cited by 1,061
Mfsd2a is critical for the formation and function of the blood-brain barrier
Ben-Zvi, A., Lacoste, B., Kur, E., Andreone, B. J., Mayshar, Y., Yan, H., & Gu, C. (2014) · Nature · doi:10.1038/nature13324 · Cited by 1,037
The Hydrodynamic Radii of Macromolecules and Their Effect on Red Blood Cell Aggregation
Armstrong, J. K., Wenby, R. B., Meiselman, H. J., & Fisher, T. C. (2004) · Biophysical Journal · doi:10.1529/biophysj.104.047746 · Cited by 820
Cited by
A guide to the organ-on-a-chip
Leung, C. M., de Haan, P., Ronaldson-Bouchard, K., Kim, G.-A., Ko, J., Rho, H. S., Chen, Z., Habibovic, P., Jeon, N. L., Takayama, S., et al. (2022) · Nature Reviews Methods Primers · doi:10.1038/s43586-022-00118-6 · Cited by 1,116
Organ-on-a-chip: recent breakthroughs and future prospects
Wu, Q., Liu, J., Wang, X., Feng, L., Wu, J., Zhu, X., Wen, W., & Gong, X. (2020) · BioMedical Engineering OnLine · doi:10.1186/s12938-020-0752-0 · Cited by 701
Park, T.-E., Mustafaoglu, N., Herland, A., Hasselkus, R., Mannix, R., FitzGerald, E. A., Prantil-Baun, R., Watters, A., Henry, O., Benz, M., et al. (2019) · Nature Communications · doi:10.1038/s41467-019-10588-0 · Cited by 594
Organ-on-a-Chip: A New Paradigm for Drug Development
Ma, C., Peng, Y., Li, H., & Chen, W. (2021) · Trends in Pharmacological Sciences · doi:10.1016/j.tips.2020.11.009 · Cited by 576
Development of Polymeric Nanoparticles for Blood–Brain Barrier Transfer—Strategies and Challenges
Zhang, W., Mehta, A., Tong, Z., Esser, L., & Voelcker, N. H. (2021) · Advanced Science · doi:10.1002/advs.202003937 · Cited by 430
Mechanisms of Blood–Brain Barrier Dysfunction in Traumatic Brain Injury
Cash, A., & Theus, M. H. (2020) · International Journal of Molecular Sciences · doi:10.3390/ijms21093344 · Cited by 318
Emerging roles for dynamic aquaporin-4 subcellular relocalization in CNS water homeostasis
Salman, M. M., Kitchen, P., Halsey, A., Wang, M. X., Törnroth-Horsefield, S., Conner, A. C., Badaut, J., Iliff, J. J., & Bill, R. M. (2022) · Brain · doi:10.1093/brain/awab311 · Cited by 303
In Vitro Models of the Blood-Brain Barrier
Neuhaus, W. (2020) · Handbook of Experimental Pharmacology · doi:10.1007/164_2020_370 · Cited by 236
Advances in Microfluidic Blood–Brain Barrier (BBB) Models
Oddo, A., Peng, B., Tong, Z., Wei, Y., Tong, W. Y., Thissen, H., & Voelcker, N. H. (2019) · Trends in Biotechnology · doi:10.1016/j.tibtech.2019.04.006 · Cited by 221
Astrocyte Activation in Neurovascular Damage and Repair Following Ischaemic Stroke
Patabendige, A., Singh, A., Jenkins, S., Sen, J., & Chen, R. (2021) · International Journal of Molecular Sciences · doi:10.3390/ijms22084280 · Cited by 211
High-Throughput Screening Platforms in the Discovery of Novel Drugs for Neurodegenerative Diseases
Aldewachi, H., Al-Zidan, R. N., Conner, M. T., & Salman, M. M. (2021) · Bioengineering · doi:10.3390/bioengineering8020030 · Cited by 207
Microfluidic organoids-on-a-chip: The future of human models
Saorin, G., Caligiuri, I., & Rizzolio, F. (2023) · Seminars in Cell & Developmental Biology · doi:10.1016/j.semcdb.2022.10.001 · Cited by 196
Achar, A., Myers, R., & Ghosh, C. (2021) · Biomedicines · doi:10.3390/biomedicines9121834 · Cited by 189
Advances in Engineering Human Tissue Models
Moysidou, C.-M., Barberio, C., & Owens, R. M. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2020.620962 · Cited by 179
“…Chang et al., 2017; Yin et al., 2020), lung (Huh et al., 2012; Stucki et al., 2018; Felder et al., 2019), blood-brain barrier (Kilic et al., 2016; Wevers et al., 2018), bone (MarturanoKruik et al., 2018), and vasculature (Schimek et al., 2013; Jeon et al., 2015) in both healthy and…”
BackgroundBenchmarking in vitro tissue-engineered blood–brain barrier models
DeStefano, J. G., Jamieson, J. J., Linville, R. M., & Searson, P. C. (2018) · Fluids and Barriers of the CNS · doi:10.1186/s12987-018-0117-2 · Cited by 142
Grifno, G. N., Farrell, A. M., Linville, R. M., Arevalo, D., Kim, J. H., Gu, L., & Searson, P. C. (2019) · Scientific Reports · doi:10.1038/s41598-019-50193-1 · Cited by 112
Microfluidic high-throughput 3D cell culture
Ko, J., Park, D., Lee, J., Jung, S., Baek, K., Sung, K. E., Lee, J., & Jeon, N. L. (2024) · Nature Reviews Bioengineering · doi:10.1038/s44222-024-00163-8 · Cited by 88
“Similarly, a bump structure, working as a capillary valve, enables the coculture of endothelial cells with astrocytes and pericytes, resulting in tight endothelial cell junctions that recapitulate the blood–brain barrier 120 .”
Brain organoid methodologies to explore mechanisms of disease in progressive multiple sclerosis
Simões-Abade, M. B. C., Patterer, M., Nicaise, A. M., & Pluchino, S. (2024) · Frontiers in Cellular Neuroscience · doi:10.3389/fncel.2024.1488691 · Cited by 14
Dufva, M. (2023) · Scientific Reports · doi:10.1038/s41598-023-35043-5 · Cited by 14
Chen, K., Linares, I. M., Trempel, M. A., Feidler, A. M., De Silva, D., Farajollahi, S., Jones, J., Kuebel, J., Kasap, P., Engelhardt, B., et al. (2025) · Advanced Science · doi:10.1002/advs.202508271 · Cited by 9
Metadata
- Authors
- Wevers, N. R., Kasi, D. G., Gray, T., Wilschut, K. J., Smith, B., van Vught, R., Shimizu, F., Sano, Y., Kanda, T., Marsh, G., Trietsch, S. J., Vulto, P., Lanz, H. L., & Obermeier, B.
- Venue
- Fluids and Barriers of the CNS
- Published
- 2018-08-31
- Volume
- 15
- Issue
- 1
- Pages
- 23-23
- ISSN
- 2045-8118 (ISSN-L)
- OpenAlex
- W2887138305
- Cited by
- 353
- References
- 74
- FWCI
- 12.14
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.