Radiotherapy based on magnetic resonance imaging as the sole modality (MRI-only RT) is an area of growing scientific interest due to the increasing use of MRI for both target and normal tissue delineation and the development of MR based delivery systems. One major issue in MRI-only RT is the assignment of electron densities (ED) to MRI scans for dose calculation and a similar need for attenuation correction can be found for hybrid PET/MR systems. The ED assigned MRI scan is here named a substitute CT (sCT). In this review, we report on a collection of typical performance values for a number of main approaches encountered in the literature for sCT generation as compared to CT. A literature search in the Scopus database resulted in 254 papers which were included in this investigation. A final number of 50 contributions which fulfilled all inclusion criteria were categorized according to applied method, MRI sequence/contrast involved, number of subjects included and anatomical site investigated. The latter included brain, torso, prostate and phantoms. The contributions geometric and/or dosimetric performance metrics were also noted. The majority of studies are carried out on the brain for 5-10 patients with PET/MR applications in mind using a voxel based method. T1 weighted images are most commonly applied. The overall dosimetric agreement is in the order of 0.3-2.5%. A strict gamma criterion of 1% and 1mm has a range of passing rates from 68 to 94% while less strict criteria show pass rates > 98%. The mean absolute error (MAE) is between 80 and 200 HU for the brain and around 40 HU for the prostate. The Dice score for bone is between 0.5 and 0.95. The specificity and sensitivity is reported in the upper 80s% for both quantities and correctly classified voxels average around 84%. The review shows that a variety of promising approaches exist that seem clinical acceptable even with standard clinical MRI sequences. A consistent reference frame for method benchmarking is probably necessary to move the field further towards a widespread clinical implementation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measures of the Amount of Ecologic Association Between Species
Dice, L. R. (1945) · Ecology · doi:10.2307/1932409 · Cited by 11,874
Comparison of PubMed, Scopus, Web of Science, and Google Scholar: strengths and weaknesses
Falagas, M. E., Pitsouni, E. I., Malietzis, G. A., & Pappas, G. (2008) · The FASEB Journal · doi:10.1096/fj.07-9492lsf · Cited by 5,039 · cited 1×
“ture search in the Scopus database November 2015 [34].”
BackgroundA technique for the quantitative evaluation of dose distributions
Low, D. A., Harms, W. B., Mutic, S., & Purdy, J. A. (1998) · Medical Physics · doi:10.1118/1.598248 · Cited by 2,880
Simple proton spectroscopic imaging.
Dixon, W. T. (1984) · Radiology · doi:10.1148/radiology.153.1.6089263 · Cited by 2,276
Performance Measurements of the Siemens mMR Integrated Whole-Body PET/MR Scanner
Delso, G., Fürst, S., Jakoby, B., Ladebeck, R., Ganter, C., Nekolla, S. G., Schwaiger, M., & Ziegler, S. I. (2011) · Journal of Nuclear Medicine · doi:10.2967/jnumed.111.092726 · Cited by 874
Magnetic Resonance: An Introduction to Ultrashort TE (UTE) Imaging
Robson, M. D., Gatehouse, P. D., Bydder, M., & Bydder, G. M. (2003) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-200311000-00001 · Cited by 717
Hofmann, M., Steinke, F., Scheel, V., Charpiat, G., Farquhar, J., Aschoff, P., Brady, M., Schölkopf, B., & Pichler, B. J. (2008) · Journal of Nuclear Medicine · doi:10.2967/jnumed.107.049353 · Cited by 495
MRI-Based Attenuation Correction for PET/MRI Using Ultrashort Echo Time Sequences
Keereman, V., Fierens, Y., Broux, T., De Deene, Y., Lonneux, M., & Vandenberghe, S. (2010) · Journal of Nuclear Medicine · doi:10.2967/jnumed.109.065425 · Cited by 442
Berker, Y., Franke, J., Salomon, A., Palmowski, M., Donker, H. C. W., Temur, Y., Mottaghy, F. M., Kuhl, C., Izquierdo-Garcia, D., Fayad, Z. A., et al. (2012) · Journal of Nuclear Medicine · doi:10.2967/jnumed.111.092577 · Cited by 344
Towards quantitative PET/MRI: a review of MR-based attenuation correction techniques
Hofmann, M., Pichler, B., Schölkopf, B., & Beyer, T. (2009) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-008-1007-7 · Cited by 343
KOSMAN, E., & LEONARD, K. J. (2005) · Molecular Ecology · doi:10.1111/j.1365-294x.2005.02416.x · Cited by 335
Johansson, A., Karlsson, M., & Nyholm, T. (2011) · Medical Physics · doi:10.1118/1.3578928 · Cited by 324
Self-citation(1977) · Radiology · doi:10.1148/124.3.812 · Cited by 318
Dowling, J. A., Lambert, J., Parker, J., Salvado, O., Fripp, J., Capp, A., Wratten, C., Denham, J. W., & Greer, P. B. (2012) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2011.11.056 · Cited by 314
Estimating CT Image From MRI Data Using Structured Random Forest and Auto-Context Model
Huynh, T., Gao, Y., Kang, J., Wang, L., Zhang, P., Lian, J., & Shen, D. (2016) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2015.2461533 · Cited by 282
Hsu, S.-H., Cao, Y., Huang, K., Feng, M., & Balter, J. M. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/23/8419 · Cited by 233
MRI for attenuation correction in PET: methods and challenges
Wagenknecht, G., Kaiser, H.-J., Mottaghy, F. M., & Herzog, H. (2013) · Magnetic Resonance Materials in Physics, Biology and Medicine · doi:10.1007/s10334-012-0353-4 · Cited by 232
Target Definition in Prostate, Head, and Neck
Rasch, C., Steenbakkers, R., & van Herk, M. (2005) · Seminars in Radiation Oncology · doi:10.1016/j.semradonc.2005.01.005 · Cited by 210
Lagendijk, J. J. W., Raaymakers, B. W., Van den Berg, C. A. T., Moerland, M. A., Philippens, M. E., & van Vulpen, M. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/21/r349 · Cited by 206
Uh, J., Merchant, T. E., Li, Y., Li, X., & Hua, C. (2014) · Medical Physics · doi:10.1118/1.4873315 · Cited by 187
Dowling, J. A., Sun, J., Pichler, P., Rivest-Hénault, D., Ghose, S., Richardson, H., Wratten, C., Martin, J., Arm, J., Best, L., et al. (2015) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2015.08.045 · Cited by 180
MRI-based treatment planning for radiotherapy: Dosimetric verification for prostate IMRT
Chen, L., Price, R. A., Wang, L., Li, J., Qin, L., McNeeley, S., Ma, C.-M. C., Freedman, G. M., & Pollack, A. (2004) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2004.05.068 · Cited by 172
Nyholm, T., Nyberg, M., Karlsson, M. G., & Karlsson, M. (2009) · Radiation Oncology · doi:10.1186/1748-717x-4-54 · Cited by 165
Self-citationGenerating patient specific pseudo-CT of the head from MR using atlas-based regression
Sjölund, J., Forsberg, D., Andersson, M., & Knutsson, H. (2015) · Physics in Medicine and Biology · doi:10.1088/0031-9155/60/2/825 · Cited by 161
Kawakami, W., Takemura, A., Yokoyama, K., Nakajima, K., Yokoyama, S., & Koshida, K. (2015) · Radiation Oncology · doi:10.1186/s13014-014-0315-2 · Cited by 158
Andreasen, D., Leemput, K. V., Hansen, R. H., Andersen, J. A. L., & Edmund, J. (2015) · Medical Physics · doi:10.1118/1.4914158 · Cited by 148
Self-citationSiversson, C., Nordström, F., Nilsson, T., Nyholm, T., Jonsson, J. H., Gunnlaugsson, A., & Olsson, L. E. (2015) · Medical Physics · doi:10.1118/1.4931417 · Cited by 147
Self-citationSchreibmann, E., Nye, J. A., Schuster, D. M., Martín, D. R., Votaw, J. R., & Fox, T. H. (2010) · Medical Physics · doi:10.1118/1.3377774 · Cited by 124
Navalpakkam, B. K., Braun, H., Kuwert, T., & Quick, H. H. (2013) · Investigative Radiology · doi:10.1097/rli.0b013e318283292f · Cited by 123
A voxel-based investigation for MRI-only radiotherapy of the brain using ultra short echo times
Edmund, J., Kjer, H. M., Leemput, K. V., Hansen, R. H., Andersen, J. A. L., & Andreasen, D. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/23/7501 · Cited by 115
Self-citationLadefoged, C. N., Benoit, D., Law, I. G., Holm, S., Kjær, A., Højgaard, L., Hansen, A. E., & Andersen, F. L. (2015) · Physics in Medicine and Biology · doi:10.1088/0031-9155/60/20/8047 · Cited by 111
Gudur, M. S. R., Hara, W. Y., Le, Q., Wang, L., Xing, L., & Li, R. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/21/6595 · Cited by 96
Roberson, P. L., McLaughlin, P. W., Narayana, V., Troyer, S., Hixson, G. V., & Kessler, M. L. (2005) · Medical Physics · doi:10.1118/1.1851920 · Cited by 93
Juttukonda, M. R., Mersereau, B. G., Chen, Y., Su, Y., Rubin, B. G., Benzinger, T. L. S., Lalush, D. S., & An, H. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2015.03.009 · Cited by 86
A patch-based pseudo-CT approach for MRI-only radiotherapy in the pelvis
Andreasen, D., Leemput, K. V., & Edmund, J. (2016) · Medical Physics · doi:10.1118/1.4958676 · Cited by 85
Self-citationDean, C. J., Sykes, J., Cooper, R., Hatfield, P., Carey, B., Swift, S. E., Bacon, S. E., Thwaites, D., Sebag‐Montefiore, D., & Morgan, A. M. (2011) · British Journal of Radiology · doi:10.1259/bjr/11855927 · Cited by 79
Su, K., Hu, L., Stehning, C., Helle, M., Qian, P., Thompson, C. L., Pereira, G. C., Jordan, D. W., Herrmann, K. A., Traughber, M. S., et al. (2015) · Medical Physics · doi:10.1118/1.4926756 · Cited by 77
Seibert, T. M., White, N. S., Kim, G.-Y., Moiseenko, V., McDonald, C. R., Farid, N., Bartsch, H., Kuperman, J. M., Karunamuni, R. A., Marshall, D. C., et al. (2016) · Practical Radiation Oncology · doi:10.1016/j.prro.2016.05.008 · Cited by 73
Rank, C. M., Tremmel, C., Hünemohr, N., Nagel, A. M., Jäkel, O., & Greilich, S. (2013) · Radiation Oncology · doi:10.1186/1748-717x-8-51 · Cited by 69
Johansson, A., Garpebring, A., Karlsson, M. C. F., Asklund, T., & Nyholm, T. (2013) · Acta Oncologica · doi:10.3109/0284186x.2013.819119 · Cited by 65
Self-citationMR-Based Attenuation Correction Using Ultrashort-Echo-Time Pulse Sequences in Dementia Patients
Cabello, J., Lukas, M., Förster, S., Pyka, T., Nekolla, S. G., & Ziegler, S. I. (2015) · Journal of Nuclear Medicine · doi:10.2967/jnumed.114.146308 · Cited by 65
MRI-based simulation of treatment plans for ion radiotherapy in the brain region
Rank, C. M., Hünemohr, N., Nagel, A. M., Röthke, M. C., Jäkel, O., & Greilich, S. (2013) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2013.10.034 · Cited by 56
Evaluation of whole‐body MR to CT deformable image registration
Akbarzadeh, A., Gutiérrez, D., Baskın, A., Ay, M. R., Ahmadian, A., Alam, N. R., Lövblad, K., & Zaidi, H. (2013) · Journal of Applied Clinical Medical Physics · doi:10.1120/jacmp.v14i4.4163 · Cited by 55
PET/MR brain imaging: evaluation of clinical UTE-based attenuation correction
Aasheim, L. B., Karlberg, A. M., Goa, P. E., Haberg, A. K., Sørhaug, S., Fagerli, U., & Eikenes, L. (2015) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-015-3060-3 · Cited by 52
Adaptive radiotherapy for long course neo-adjuvant treatment of rectal cancer
Nijkamp, J. A., Marijnen, C. A. M., van Herk, M., van Triest, B., & Sonke, J. (2012) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2012.02.013 · Cited by 36
Andreasen, D., Edmund, J., Zografos, V., Menze, B. H., & Leemput, K. V. (2016) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2216924 · Cited by 34
Self-citationYang, X., & Fei, B. (2013) · Journal of the American Medical Informatics Association · doi:10.1136/amiajnl-2012-001544 · Cited by 32
Jonsson, J. H., Akhtari, M. M., Karlsson, M. G., Johansson, A., Asklund, T., & Nyholm, T. (2015) · Radiation Oncology · doi:10.1186/s13014-014-0308-1 · Cited by 32
Self-citationKhateri, P., Rad, H. S., Jafari, A. H., Kazerooni, A. F., Akbarzadeh, A., Moghadam, M. S., Aryan, A., Ghafarian, P., & Ay, M. R. (2015) · Molecular Imaging and Biology · doi:10.1007/s11307-015-0849-1 · Cited by 28
Hybrid approach for attenuation correction in PET/MR scanners
Ribeiro, A., Kops, E. R., Herzog, H. R., & Almeida, P. M. D. (2013) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2013.09.034 · Cited by 28
Ribeiro, A., Kops, E. R., Herzog, H. R., & Almeida, P. M. D. (2012) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2012.09.005 · Cited by 19
CT-based evaluation of segmented head regions for attenuation correction in MR-PET systems
Wagenknecht, G., Kops, E. R., Kaffanke, J. B., Tellmann, L., Mottaghy, F. M., Piroth, M. D., & Herzog, H. (2010) · IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) · doi:10.1109/nssmic.2010.5874301 · Cited by 16
Automated Classification of Bone and Air Volumes for Hybrid PET-MRI Brain Imaging
Chan, S. L. S., Jeffree, R. L., Fay, M. F., Crozier, ., Yang, Z., Gal, Y., & Thomas, P. A. (2013) · International Conference on Digital Image Computing: Techniques and Applications (DICTA) · doi:10.1109/dicta.2013.6691483 · Cited by 15
Is Less, More? The Evolving Role of Radiation Therapy for Brain Metastases
Soltys, S. G., Kirkpatrick, J. P., Laack, N. N. I., Kavanagh, B. D., Breneman, J. C., & Shih, H. A. (2015) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2015.03.003 · Cited by 12
MRI based attenuation correction for PET/MRI via MRF segmentation and sparse regression estimated CT
Chen, Y., Juttukonda, M. R., Lee, Y. Z., Su, Y., Espinoza, F., Lin, W., Shen, D. G., Lulash, D., & An, H. (2014) · IEEE International Symposium on Biomedical Imaging (ISBI) · doi:10.1109/isbi.2014.6868131 · Cited by 9
Classification of bones from MR images in torso PET-MR imaging using a statistical shape model
Ay, M. R., Akbarzadeh, A., Ahmadian, A., & Zaidi, H. (2013) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2013.09.007 · Cited by 7
Cited by
Deep MR to CT Synthesis Using Unpaired Data
Wolterink, J. M., Dinkla, A. M., Savenije, M. H. F., Seevinck, P. R., van den Berg, C. A. T., & Išgum, I. (2017) · Lecture Notes in Computer Science · doi:10.1007/978-3-319-68127-6_2 · Cited by 593
Vandewinckele, L., Claessens, M., Dinkla, A., Brouwer, C., Crijns, W., Verellen, D., & van Elmpt, W. (2020) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2020.09.008 · Cited by 321
Johnstone, E., Wyatt, J. J., Henry, A. M., Short, S. C., Sebag-Montefiore, D., Murray, L., Kelly, C. G., McCallum, H. M., & Speight, R. (2018) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2017.08.043 · Cited by 317
Survey on deep learning for radiotherapy
Meyer, P., Noblet, V., Mazzara, C., & Lallement, A. (2018) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2018.05.018 · Cited by 302
Adaptive Radiotherapy for Anatomical Changes
Sonke, J.-J., Aznar, M., & Rasch, C. (2019) · Seminars in Radiation Oncology · doi:10.1016/j.semradonc.2019.02.007 · Cited by 301
Metadata
- Authors
- Edmund, J. M., & Nyholm, T.
- Venue
- Radiation Oncology
- Published
- 2017-01-26
- Volume
- 12
- Issue
- 1
- Pages
- 28-28
- ISSN
- 1748-717X (ISSN-L)
- OpenAlex
- W2580163862
- Cited by
- 378
- References
- 56
- FWCI
- 41.17
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.