CoChat

MRI for attenuation correction in PET: methods and challenges

Open access
Wagenknecht, Gudrun, Kaiser, Hans-Jürgen, Mottaghy, Felix M., Herzog, Hans · 2013 · Magnetic Resonance Materials in Physics, Biology and Medicine
Cited by 232

The DOI matches its Crossref record; 56 of the 56 references it cites were found in a registry or an index.

Abstract

In current combined PET/MR systems, PET attenuation correction is based on MRI, since the small bore inside MRI systems and the strong magnetic field do not permit a rotating PET transmission source or a CT device to be integrated. Unlike CT measurements in PET/CT scanners, the MR signal is not directly correlated to tissue density and thus cannot be converted by a simple transformation of intensity values. Various approaches have been developed based on templates, atlas information, direct segmentation of T1-weighted MR images, or segmentation of images from special MR sequences. The advantages and disadvantages of these approaches as well as additional challenges will be discussed in this review.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1007/s10334-012-0353-4

Cites

56 of 56 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 56 references

Cited by

See all 232

Metadata

Authors
Wagenknecht, G., Kaiser, H.-J., Mottaghy, F. M., & Herzog, H.
Venue
Magnetic Resonance Materials in Physics, Biology and Medicine
Published
2012-11-21
Volume
26
Issue
1
Pages
99-113
ISSN
  • 0968-5243 (ISSN-L)
  • 1352-8661
OpenAlex
W1991035308
Cited by
232
References
56
FWCI
12.46
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: MRI for attenuation correction in PET: methods and challenges. https://app.cochat.ai/papers/10.1007/s10334-012-0353-4
The paper
Wagenknecht, G., Kaiser, H.-J., Mottaghy, F. M., & Herzog, H. (2013). MRI for attenuation correction in PET: methods and challenges. Magnetic Resonance Materials in Physics, Biology and Medicine. https://doi.org/10.1007/s10334-012-0353-4

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.