A review of substitute CT generation for MRI-only radiation therapy
Open accessThe DOI matches its Crossref record; 56 of the 56 references it cites were found in a registry or an index.
Abstract
Radiotherapy based on magnetic resonance imaging as the sole modality (MRI-only RT) is an area of growing scientific interest due to the increasing use of MRI for both target and normal tissue delineation and the development of MR based delivery systems. One major issue in MRI-only RT is the assignment of electron densities (ED) to MRI scans for dose calculation and a similar need for attenuation correction can be found for hybrid PET/MR systems. The ED assigned MRI scan is here named a substitute CT (sCT). In this review, we report on a collection of typical performance values for a number of main approaches encountered in the literature for sCT generation as compared to CT. A literature search in the Scopus database resulted in 254 papers which were included in this investigation. A final number of 50 contributions which fulfilled all inclusion criteria were categorized according to applied method, MRI sequence/contrast involved, number of subjects included and anatomical site investigated. The latter included brain, torso, prostate and phantoms. The contributions geometric and/or dosimetric performance metrics were also noted. The majority of studies are carried out on the brain for 5-10 patients with PET/MR applications in mind using a voxel based method. T1 weighted images are most commonly applied. The overall dosimetric agreement is in the order of 0.3-2.5%. A strict gamma criterion of 1% and 1mm has a range of passing rates from 68 to 94% while less strict criteria show pass rates > 98%. The mean absolute error (MAE) is between 80 and 200 HU for the brain and around 40 HU for the prostate. The Dice score for bone is between 0.5 and 0.95. The specificity and sensitivity is reported in the upper 80s% for both quantities and correctly classified voxels average around 84%. The review shows that a variety of promising approaches exist that seem clinical acceptable even with standard clinical MRI sequences. A consistent reference frame for method benchmarking is probably necessary to move the field further towards a widespread clinical implementation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measures of the Amount of Ecologic Association Between Species
Dice, L. R. (1945) · Ecology · doi:10.2307/1932409 · Cited by 11,874
Comparison of PubMed, Scopus, Web of Science, and Google Scholar: strengths and weaknesses
Falagas, M. E., Pitsouni, E. I., Malietzis, G. A., & Pappas, G. (2008) · The FASEB Journal · doi:10.1096/fj.07-9492lsf · Cited by 5,039 · cited 1×
“ture search in the Scopus database November 2015 [34].”
BackgroundA technique for the quantitative evaluation of dose distributions
Low, D. A., Harms, W. B., Mutic, S., & Purdy, J. A. (1998) · Medical Physics · doi:10.1118/1.598248 · Cited by 2,880
Simple proton spectroscopic imaging.
Dixon, W. T. (1984) · Radiology · doi:10.1148/radiology.153.1.6089263 · Cited by 2,276
Performance Measurements of the Siemens mMR Integrated Whole-Body PET/MR Scanner
Delso, G., Fürst, S., Jakoby, B., Ladebeck, R., Ganter, C., Nekolla, S. G., Schwaiger, M., & Ziegler, S. I. (2011) · Journal of Nuclear Medicine · doi:10.2967/jnumed.111.092726 · Cited by 874
Magnetic Resonance: An Introduction to Ultrashort TE (UTE) Imaging
Robson, M. D., Gatehouse, P. D., Bydder, M., & Bydder, G. M. (2003) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-200311000-00001 · Cited by 717
Hofmann, M., Steinke, F., Scheel, V., Charpiat, G., Farquhar, J., Aschoff, P., Brady, M., Schölkopf, B., & Pichler, B. J. (2008) · Journal of Nuclear Medicine · doi:10.2967/jnumed.107.049353 · Cited by 495
MRI-Based Attenuation Correction for PET/MRI Using Ultrashort Echo Time Sequences
Keereman, V., Fierens, Y., Broux, T., De Deene, Y., Lonneux, M., & Vandenberghe, S. (2010) · Journal of Nuclear Medicine · doi:10.2967/jnumed.109.065425 · Cited by 442
Berker, Y., Franke, J., Salomon, A., Palmowski, M., Donker, H. C. W., Temur, Y., Mottaghy, F. M., Kuhl, C., Izquierdo-Garcia, D., Fayad, Z. A., et al. (2012) · Journal of Nuclear Medicine · doi:10.2967/jnumed.111.092577 · Cited by 344
Towards quantitative PET/MRI: a review of MR-based attenuation correction techniques
Hofmann, M., Pichler, B., Schölkopf, B., & Beyer, T. (2009) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-008-1007-7 · Cited by 343
Cited by
Deep MR to CT Synthesis Using Unpaired Data
Wolterink, J. M., Dinkla, A. M., Savenije, M. H. F., Seevinck, P. R., van den Berg, C. A. T., & Išgum, I. (2017) · Lecture Notes in Computer Science · doi:10.1007/978-3-319-68127-6_2 · Cited by 593
Vandewinckele, L., Claessens, M., Dinkla, A., Brouwer, C., Crijns, W., Verellen, D., & van Elmpt, W. (2020) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2020.09.008 · Cited by 321
Johnstone, E., Wyatt, J. J., Henry, A. M., Short, S. C., Sebag-Montefiore, D., Murray, L., Kelly, C. G., McCallum, H. M., & Speight, R. (2018) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2017.08.043 · Cited by 317
Survey on deep learning for radiotherapy
Meyer, P., Noblet, V., Mazzara, C., & Lallement, A. (2018) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2018.05.018 · Cited by 302
Adaptive Radiotherapy for Anatomical Changes
Sonke, J.-J., Aznar, M., & Rasch, C. (2019) · Seminars in Radiation Oncology · doi:10.1016/j.semradonc.2019.02.007 · Cited by 301
MRI‐only based synthetic CT generation using dense cycle consistent generative adversarial networks
Lei, Y., Harms, J., Wang, T., Liu, Y., Shu, H., Jani, A. B., Curran, W. J., Mao, H., Liu, T., & Yang, X. (2019) · Medical Physics · doi:10.1002/mp.13617 · Cited by 297
Maspero, M., Savenije, M. H. F., Dinkla, A. M., Seevinck, P. R., Intven, M. P. W., Jurgenliemk-Schulz, I. M., Kerkmeijer, L. G. W., & van den Berg, C. A. T. (2018) · Physics in Medicine & Biology · doi:10.1088/1361-6560/aada6d · Cited by 253
MRI-only treatment planning: benefits and challenges
Owrangi, A. M., Greer, P. B., & Glide-Hurst, C. K. (2018) · Physics in Medicine & Biology · doi:10.1088/1361-6560/aaaca4 · Cited by 236
“Systematic overviews of method types have recently been reported (Edmund and Nyholm 2017, Johnstone et al 2017).”
MethodFlorkow, M. C., Willemsen, K., Mascarenhas, V. V., Oei, E. H. G., van Stralen, M., & Seevinck, P. R. (2022) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.28067 · Cited by 232
Deep CT to MR Synthesis Using Paired and Unpaired Data
Jin, C.-B., Kim, H., Liu, M., Jung, W., Joo, S., Park, E., Ahn, Y., Han, I., Lee, J., & Cui, X. (2019) · Sensors · doi:10.3390/s19102361 · Cited by 224
Deep learning methods to generate synthetic CT from MRI in radiotherapy: A literature review
Boulanger, M., Nunes, J.-C., Chourak, H., Largent, A., Tahri, S., Acosta, O., De Crevoisier, R., Lafond, C., & Barateau, A. (2021) · Physica Medica · doi:10.1016/j.ejmp.2021.07.027 · Cited by 209
“Two reviews, both published in 2018, have already summarized sCT generation methods from MRI [21,22], they focused only on the bulk”
BackgroundLiu, Y., Lei, Y., Wang, T., Fu, Y., Tang, X., Curran, W. J., Liu, T., Patel, P., & Yang, X. (2020) · Medical Physics · doi:10.1002/mp.14121 · Cited by 205
Deep learning based synthetic‐CT generation in radiotherapy and PET: A review
Spadea, M. F., Maspero, M., Zaffino, P., & Seco, J. (2021) · Medical Physics · doi:10.1002/mp.15150 · Cited by 201
Sorin, V., Barash, Y., Konen, E., & Klang, E. (2020) · Academic Radiology · doi:10.1016/j.acra.2019.12.024 · Cited by 195
Jans, L. B. O., Chen, M., Elewaut, D., Van den Bosch, F., Carron, P., Jacques, P., Wittoek, R., Jaremko, J. L., & Herregods, N. (2021) · Radiology · doi:10.1148/radiol.2020201537 · Cited by 175
Kazemifar, S., McGuire, S., Timmerman, R., Wardak, Z., Nguyen, D., Park, Y., Jiang, S., & Owrangi, A. (2019) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2019.03.026 · Cited by 164
“comparing the dose distributions generated in both image sets. DVH and gamma analysis showed high agreement between both dose distribution sets. To measure a geometric score, we used the DSC for bone [22] to describe the overlap between the CT and synthetic CT bone volumes. When we compared the two loss functions (MAE…”
MethodInfluentialNyholm, T., Svensson, S., Andersson, S., Jonsson, J., Sohlin, M., Gustafsson, C., Kjellén, E., Söderström, K., Albertsson, P., Blomqvist, L., et al. (2018) · Medical Physics · doi:10.1002/mp.12748 · Cited by 104
Self-citation
Metadata
- Authors
- Edmund, J. M., & Nyholm, T.
- Venue
- Radiation Oncology
- Published
- 2017-01-26
- Volume
- 12
- Issue
- 1
- Pages
- 28-28
- ISSN
- 1748-717X (ISSN-L)
- OpenAlex
- W2580163862
- Cited by
- 378
- References
- 56
- FWCI
- 41.17
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.