Hypervolemia increases release of atrial natriuretic peptide and shedding of the endothelial glycocalyx
Open accessThe DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Abstract
Introduction: Acute normovolemic hemodilution (ANH) and volume loading (VL) are standard blood-sparing procedures. However, VL is associated with hypervolemia, which may cause tissue edema, cardiopulmonary complications and a prolonged hospital stay. The body reacts to hypervolemia with release of atrial natriuretic peptide (ANP) from the heart. ANP has been shown to deteriorate the endothelial glycocalyx, a vital part of the vascular permeability barrier. The aim of the present study was to evaluate and compare ANP release and damage to the glycocalyx during ANH and VL. Methods: ANH or VL with 6% hydroxyethyl starch 130/0.4 was administered prior to elective surgery in patients of good cardiopulmonary health (n =9 in each group). We measured concentrations of ANP in plasma and of three main constituent parts of the glycocalyx (hyaluronan, heparan sulfate and syndecan 1) in serum before and after ANH or VL. Heparan sulfate and syndecan 1 levels in urine were also determined. Results: In contrast to ANH, VL (20 ml/kg) induced a significant release of ANP (approximately +100%, P <0.05) and increased the serum concentration of two glycocalyx constituents, hyaluronan and syndecan 1 (both by about 80%, P <0.05). Elevation of syndecan 1 was also detected in the urine of patients undergoing VL, but no increase was found in patients undergoing ANH. Heparan sulfate levels were not influenced by either procedure. Conclusion: These data suggest that hypervolemia increases the release of ANP and causes enhanced shedding of the endothelial glycocalyx. This perturbation must be expected to impair the vascular barrier, implying that VL may not be as safe as generally assumed and that it should be critically evaluated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intravenous Fluids and Acute Kidney Injury
Ding, X., Cheng, Z., & Qian, Q. (2017) · Blood Purification · doi:10.1159/000452702 · Cited by 6,827
Hydroxyethyl Starch 130/0.42 versus Ringer's Acetate in Severe Sepsis
Perner, A., Haase, N., Guttormsen, A. B., Tenhunen, J., Klemenzson, G., Åneman, A., Madsen, K. R., Møller, M. H., Elkjær, J. M., Poulsen, L. M., et al. (2012) · New England Journal of Medicine · doi:10.1056/nejmoa1204242 · Cited by 1,813
Hydroxyethyl Starch or Saline for Fluid Resuscitation in Intensive Care
Myburgh, J. A., Finfer, S., Bellomo, R., Billot, L., Cass, A., Gattas, D., Glass, P., Lipman, J., Liu, B., McArthur, C., et al. (2012) · New England Journal of Medicine · doi:10.1056/nejmoa1209759 · Cited by 1,687
Brandstrup, B., Tønnesen, H., Beier-Holgersen, R., Hjortsø, E., Ørding, H., Lindorff-Larsen, K., Rasmussen, M. S., Lanng, C., Wallin, L., Iversen, L. H., et al. (2003) · Annals of Surgery · doi:10.1097/01.sla.0000094387.50865.23 · Cited by 1,585
Albumin Replacement in Patients with Severe Sepsis or Septic Shock
Caironi, P., Tognoni, G., Masson, S., Fumagalli, R., Pesenti, A., Romero, M., Fanizza, C., Caspani, L., Faenza, S., Grasselli, G., et al. (2014) · New England Journal of Medicine · doi:10.1056/nejmoa1305727 · Cited by 1,324
The Structure and Function of the Endothelial Glycocalyx Layer
Weinbaum, S., Tarbell, J. M., & Damiano, E. R. (2007) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.9.060906.151959 · Cited by 1,198
Lobo, D. N., Bostock, K. A., Neal, K. R., Perkins, A. C., Rowlands, B. J., & Allison, S. P. (2002) · The Lancet · doi:10.1016/s0140-6736(02)08711-1 · Cited by 1,038
A Rational Approach to Perioperative Fluid Management
Chappell, D., Jacob, M., Hofmann-Kiefer, K., Conzen, P., & Rehm, M. (2008) · Anesthesiology · doi:10.1097/aln.0b013e3181863117 · Cited by 909
Self-citationPries, A. R., Secomb, T. W., & Gaehtgens, P. (2000) · Pflügers Archiv - European Journal of Physiology · doi:10.1007/s004240000307 · Cited by 898
Effect of Intraoperative Fluid Management on Outcome after Intraabdominal Surgery
Nisanevich, V., Felsenstein, I., Almogy, G., Weissman, C., Einav, S., & Matot, I. (2005) · Anesthesiology · doi:10.1097/00000542-200507000-00008 · Cited by 864
Cited by
Endothelial Responses in Sepsis
Joffre, J., Hellman, J., Ince, C., & Ait-Oufella, H. (2020) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201910-1911tr · Cited by 713
The glycocalyx: a novel diagnostic and therapeutic target in sepsis
Uchimido, R., Schmidt, E. P., & Shapiro, N. I. (2019) · Critical Care · doi:10.1186/s13054-018-2292-6 · Cited by 710
Degradation of the endothelial glycocalyx in clinical settings: searching for the sheddases
Becker, B. F., Jacob, M., Leipert, S., Salmon, A. H. J., & Chappell, D. (2015) · British Journal of Clinical Pharmacology · doi:10.1111/bcp.12629 · Cited by 464
Self-citationDerangement of the endothelial glycocalyx in sepsis
Iba, T., & Levy, J. H. (2019) · Journal of Thrombosis and Haemostasis · doi:10.1111/jth.14371 · Cited by 322
The effects of sepsis on endothelium and clinical implications
Dolmatova, E. V., Wang, K., Mandavilli, R., & Griendling, K. K. (2021) · Cardiovascular Research · doi:10.1093/cvr/cvaa070 · Cited by 317
2023 Update on Sepsis and Septic Shock in Adult Patients: Management in the Emergency Department
Guarino, M., Perna, B., Cesaro, A. E., Maritati, M., Spampinato, M. D., Contini, C., & De Giorgio, R. (2023) · Journal of Clinical Medicine · doi:10.3390/jcm12093188 · Cited by 294
Intravenous fluid resuscitation is associated with septic endothelial glycocalyx degradation
Hippensteel, J. A., Uchimido, R., Tyler, P. D., Burke, R. C., Han, X., Zhang, F., McMurtry, S. A., Colbert, J. F., Lindsell, C. J., Angus, D. C., et al. (2019) · Critical Care · doi:10.1186/s13054-019-2534-2 · Cited by 213
The endothelial glycocalyx and its disruption, protection and regeneration: a narrative review
Schött, U., Solomon, C., Fries, D., & Bentzer, P. (2016) · Scandinavian Journal of Trauma, Resuscitation and Emergency Medicine · doi:10.1186/s13049-016-0239-y · Cited by 182
“Shedding of the glycocalyx in humans has been demonstrated in response to hypovolaemia [31] and has also been observed in patients undergoing aortic or cardiac bypass surgery [12, 32].”
BackgroundRegulation of blood flow and volume exchange across the microcirculation
Jacob, M., Chappell, D., & Becker, B. F. (2016) · Critical Care · doi:10.1186/s13054-016-1485-0 · Cited by 179
“Natriuretic peptides have been linked to volume extravasation and have also been found to shed the glycocalyx in coronary bypass surgery [44, 45].”
BackgroundSelf-citationfor the DoReMIFA study group, Garzotto, F., Ostermann, M., Martín-Langerwerf, D., Sánchez-Sánchez, M., Teng, J., Robert, R., Marinho, A., Herrera-Gutierrez, M. E., Mao, H. J., et al. (2016) · Critical Care · doi:10.1186/s13054-016-1355-9 · Cited by 160
“Moreover, the higher the MFO, the wider the difference in mortality between the AKI and N-AKI cohort, which suggests that FO aggravates the patients’ underlying condition [18, 19].”
BackgroundFluid resuscitation in sepsis: the great 30 mL per kg hoax
Marik, P. E., Byrne, L., & van Haren, F. (2020) · Journal of Thoracic Disease · doi:10.21037/jtd.2019.12.84 · Cited by 116
Fluids or vasopressors for the initial resuscitation of septic shock
Macdonald, S., Peake, S. L., Corfield, A. R., & Delaney, A. (2022) · Frontiers in Medicine · doi:10.3389/fmed.2022.1069782 · Cited by 6
Metadata
- Authors
- Chappell, D., Bruegger, D., Potzel, J., Jacob, M., Brettner, F., Vogeser, M., Conzen, P., Becker, B. F., & Rehm, M.
- Venue
- Critical Care
- Published
- 2014-10-13
- Volume
- 18
- Issue
- 5
- Pages
- 538-538
- ISSN
- 1364-8535 (ISSN-L)
- OpenAlex
- W2112223256
- Cited by
- 336
- References
- 36
- FWCI
- 12.57
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.