How to measure blood pressure using an arterial catheter: a systematic 5-step approach
Open accessThe DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Abstract
Arterial blood pressure (BP) is a fundamental cardiovascular variable, is routinely measured in perioperative and intensive care medicine, and has a significant impact on patient management. The clinical reference method for BP monitoring in high-risk surgical patients and critically ill patients is continuous invasive BP measurement using an arterial catheter. A key prerequisite for correct invasive BP monitoring using an arterial catheter is an in-depth understanding of the measurement principle, of BP waveform quality criteria, and of common pitfalls that can falsify BP readings. Here, we describe how to place an arterial catheter, correctly measure BP, and identify and solve common pitfalls. We focus on 5 important steps, namely (1) how to choose the catheter insertion site, (2) how to choose the type of arterial catheter, (3) how to place the arterial catheter, (4) how to level and zero the transducer, and (5) how to check the quality of the BP waveform.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cecconi, M., De Backer, D., Antonelli, M., Beale, R., Bakker, J., Hofer, C., Jaeschke, R., Mebazaa, A., Pinsky, M. R., Teboul, J. L., et al. (2014) · Intensive Care Medicine · doi:10.1007/s00134-014-3525-z · Cited by 1,767
Salmasi, V., Maheshwari, K., Yang, D., Mascha, E. J., Singh, A., Sessler, D. I., & Kurz, A. (2017) · Anesthesiology · doi:10.1097/aln.0000000000001432 · Cited by 1,104
Scheer, B., Perel, A., & Pfeiffer, U. J. (2002) · Critical Care · doi:10.1186/cc1489 · Cited by 854
Heparin-Induced Thrombocytopenia
Greinacher, A. (2015) · New England Journal of Medicine · doi:10.1056/nejmcp1411910 · Cited by 608
O'Grady, N. P., Alexander, M., Burns, L. A., Dellinger, E. P., Garland, J., Heard, S. O., Lipsett, P. A., Masur, H., Mermel, L. A., Pearson, M. L., et al. (2011) · Clinical Infectious Diseases · doi:10.1093/cid/cir138 · Cited by 560
Direct Blood Pressure Measurement —Dynamic Response Requirements
Gardner, R. M. (1981) · Anesthesiology · doi:10.1097/00000542-198103000-00010 · Cited by 518
Saugel, B., Scheeren, T. W. L., & Teboul, J.-L. (2017) · Critical Care · doi:10.1186/s13054-017-1814-y · Cited by 481
Self-citationTroianos, C. A., Hartman, G. S., Glas, K. E., Skubas, N. J., Eberhardt, R. T., Walker, J. D., & Reeves, S. T. (2011) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2011.09.021 · Cited by 420
On the Safety of Radial Artery Cannulation
Slogoff, S., Keats, A. S., & Arlund, C. (1983) · Anesthesiology · doi:10.1097/00000542-198307000-00008 · Cited by 355
Radial Artery Cannulation: A Comprehensive Review of Recent Anatomic and Physiologic Investigations
Brzezinski, M., Luisetti, T., & London, M. J. (2009) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e3181bbd416 · Cited by 354
World Health Organization: global guidelines for the prevention of surgical site infection
Leaper, D. J., & Edmiston, C. E. (2017) · Journal of Hospital Infection · doi:10.1016/j.jhin.2016.12.016 · Cited by 340
Less invasive hemodynamic monitoring in critically ill patients
Teboul, J.-L., Saugel, B., Cecconi, M., De Backer, D., Hofer, C. K., Monnet, X., Perel, A., Pinsky, M. R., Reuter, D. A., Rhodes, A., et al. (2016) · Intensive Care Medicine · doi:10.1007/s00134-016-4375-7 · Cited by 328
Self-citationAssociation of Anaesthetists of Great Britain and Ireland: Safe vascular access 2016
Bodenham (Chair), A., Babu, S., Bennett, J., Binks, R., Fee, P., Fox, B., Johnston, A. J., Klein, A. A., Langton, J. A., Mclure, H., et al. (2016) · Anaesthesia · doi:10.1111/anae.13360 · Cited by 309
The relationship between ICU hypotension and in-hospital mortality and morbidity in septic patients
Maheshwari, K., Nathanson, B. H., Munson, S. H., Khangulov, V., Stevens, M., Badani, H., Khanna, A. K., & Sessler, D. I. (2018) · Intensive Care Medicine · doi:10.1007/s00134-018-5218-5 · Cited by 301
Gelb, A. W., Morriss, W. W., Johnson, W. D., Merry, A., Abayadeera, A., Belîi, N., Brull, S. J., Chibana, A., Evans, F., Goddia, C., et al. (2018) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000002927 · Cited by 298
Methods of Blood Pressure Measurement in the ICU*
Lehman, L.-W. H., Saeed, M., Talmor, D., Mark, R., & Malhotra, A. (2013) · Critical Care Medicine · doi:10.1097/ccm.0b013e318265ea46 · Cited by 224
Kim, S.-H., Lilot, M., Sidhu, K. S., Rinehart, J., Yu, Z., Canales, C., & Cannesson, M. (2014) · Anesthesiology · doi:10.1097/aln.0000000000000226 · Cited by 207
Accuracy of invasive arterial pressure monitoring in cardiovascular patients: an observational study
Romagnoli, S., Ricci, Z., Quattrone, D., Tofani, L., Tujjar, O., Villa, G., Romano, S. M., & De Gaudio, A. R. (2014) · Critical Care · doi:10.1186/s13054-014-0644-4 · Cited by 191
Self-citationReliability of Allen’s test in selection of patients for radial artery harvest
Jarvis, M. A., Jarvis, C. L., Jones, P. R. M., & Spyt, T. J. (2000) · The Annals of Thoracic Surgery · doi:10.1016/s0003-4975(00)01551-4 · Cited by 183
Invasive and Concomitant Noninvasive Intraoperative Blood Pressure Monitoring
Wax, D. B., Lin, H.-M., & Leibowitz, A. B. (2011) · Anesthesiology · doi:10.1097/aln.0b013e3182330286 · Cited by 178
AN EXPERIMENTAL STUDY OF THE STANDING WAVES IN THE PULSE PROPAGATED THROUGH THE AORTA
Hamilton, W. F., & Dow, P. (1938) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1938.125.1.48 · Cited by 175
Arterial Catheters as a Source of Bloodstream Infection: A Systematic Review and Meta-Analysis*
O’Horo, J. C., Maki, D. G., Krupp, A. E., & Safdar, N. (2014) · Critical Care Medicine · doi:10.1097/ccm.0000000000000166 · Cited by 174
A Randomized Trial of Continuous Noninvasive Blood Pressure Monitoring During Noncardiac Surgery
Maheshwari, K., Khanna, S., Bajracharya, G. R., Makarova, N., Riter, Q., Raza, S., Cywinski, J. B., Argalious, M., Kurz, A., & Sessler, D. I. (2018) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000003482 · Cited by 173
Surgical and Patient Risk Factors for Severe Arterial Line Complications in Adults
Nuttall, G., Burckhardt, J., Hadley, A., Kane, S., Kor, D., Marienau, M. S., Schroeder, D. R., Handlogten, K., Wilson, G., & Oliver, W. C. (2016) · Anesthesiology · doi:10.1097/aln.0000000000000967 · Cited by 162
Saugel, B., Dueck, R., & Wagner, J. Y. (2014) · Best Practice & Research Clinical Anaesthesiology · doi:10.1016/j.bpa.2014.08.001 · Cited by 162
Self-citationBlood Pressure Monitoring for the Anesthesiologist: A Practical Review
Bartels, K., Esper, S. A., & Thiele, R. H. (2016) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000001340 · Cited by 161
Pacha, H. M., Alahdab, F., Al‐Khadra, Y., Idris, A., Rabbat, F., Darmoch, F., Soud, M., Zaitoun, A., Kaki, A., Rao, S. V., et al. (2018) · American Heart Journal · doi:10.1016/j.ahj.2018.06.007 · Cited by 118
The accuracy of noninvasive cardiac output and pressure measurements with finger cuff
Ameloot, K., Palmers, P., & Malbrain, M. L. N. G. (2015) · Current Opinion in Critical Care · doi:10.1097/mcc.0000000000000198 · Cited by 113
Kiberenge, R. K., Ueda, K., & Rosauer, B. (2017) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000002261 · Cited by 92
Bhattacharjee, S., Maitra, S., & Baidya, D. K. (2018) · Journal of Clinical Anesthesia · doi:10.1016/j.jclinane.2018.03.019 · Cited by 91
Bazaral, M. G., Welch, M. J., Golding, L. A. R., & Badhwar, K. (1990) · Anesthesiology · doi:10.1097/00000542-199007000-00007 · Cited by 81
Naylor, A. J., Sessler, D. I., Maheshwari, K. K., Khanna, A. K., Yang, D., Mascha, E. J., Suleiman, I., Reville, E. M., Cote, D. R., Hutcherson, M. T., et al. (2019) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000004370 · Cited by 73 · cited 1×
“In addition, continuous invasive BP monitoring detects twice as much intraoperative hypotension than intermittent non-invasive measurements using oscillometry and triggers vasopressor therapy in adults having non-cardiac surgery [9].”
BackgroundMeidert, A. S., Nold, J. S., Hornung, R., Paulus, A. C., Zwißler, B., & Czerner, S. F. A. (2017) · European Journal of Anaesthesiology · doi:10.1097/eja.0000000000000690 · Cited by 69
Self-citationReview of Ultrasound-Guided Radial Artery Catheter Placement
Miller, A. G., & Bardin-Spencer, A. J. (2015) · Respiratory Care · doi:10.4187/respcare.04190 · Cited by 68
Brachial Arterial Pressure Monitoring during Cardiac Surgery Rarely Causes Complications
Singh, A., Bahadorani, B., Wakefield, B. J., Makarova, N., Kumar, P. A., Tong, M. Z.-Y., Sessler, D. I., & Duncan, A. E. (2017) · Anesthesiology · doi:10.1097/aln.0000000000001626 · Cited by 49
Karacalar, S., Türe, H., Bari̇ş, S., Karakaya, D., & Sarıhasan, B. (2007) · Journal of Clinical Anesthesia · doi:10.1016/j.jclinane.2006.10.012 · Cited by 23
Pasma, W., Peelen, L. M., van Buuren, S., van Klei, W. A., & de Graaff, J. C. (2020) · Anesthesiology · doi:10.1097/aln.0000000000003131 · Cited by 19 · cited 1×
“In addition, substantial variations in BP reading between different measurement systems may occur because different monitor devices use different algorithms for data processing, data averaging, and artifact filtering [48].”
BackgroundHtet, N. N., Vaughn, J., Adigopula, S., Hennessey, E., & Mihm, F. G. (2017) · Journal of Critical Care · doi:10.1016/j.jcrc.2017.05.026 · Cited by 19
Resonance artefacts in modern pressure monitoring systems
Bocchi, L., & Romagnoli, S. (2015) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-015-9760-1 · Cited by 12
Self-citation
Cited by
Perioperative Blood Pressure Management
Saugel, B., & Sessler, D. I. (2021) · Anesthesiology · doi:10.1097/aln.0000000000003610 · Cited by 191
“, “damping”) is adequate.(38) Continuous invasive blood pressure monitoring detects twice as many hypotensive minutes, and triggers a third more vasopressor boluses than intermittent oscillometric blood pressure measurements in patients having major noncardiac surgery.”
BackgroundSelf-citationSaugel, B., Fletcher, N., Gan, T. J., Grocott, M. P. W., Myles, P. S., Sessler, D. I., Auzinger, G., Chappell, D., Gan, T. J., Edwards, M., et al. (2024) · British Journal of Anaesthesia · doi:10.1016/j.bja.2024.04.046 · Cited by 180
“43 Continuous intraarterial monitoring provides arterial pressure in real-time and helps clinicians detect and treat arterial pressure changes immediately.”
Self-citationSaugel, B., Kouz, K., Scheeren, T. W. L., Greiwe, G., Hoppe, P., Romagnoli, S., & de Backer, D. (2021) · British Journal of Anaesthesia · doi:10.1016/j.bja.2020.09.049 · Cited by 163
Self-citationManagement of sepsis and septic shock in the emergency department
Gavelli, F., Castello, L. M., & Avanzi, G. C. (2021) · Internal and Emergency Medicine · doi:10.1007/s11739-021-02735-7 · Cited by 161
“Under these conditions, vasopressor treatment can be initiated on a peripheral venous line with non-invasive BP monitoring, and it should be shifted, as soon as possible, to CVC administration accompanied by invasive arterial pressure monitoring [41, 54].”
BackgroundMeasurements of arterial pressure and flow in vivo
Sharman, J. E., Segers, P., & Chirinos, J. A. (2022) · Textbook of Arterial Stiffness and Pulsatile Hemodynamics in Health and Disease · doi:10.1016/b978-0-323-91391-1.00002-9 · Cited by 3
Metadata
- Authors
- Saugel, B., Kouz, K., Meidert, A. S., Schulte-Uentrop, L., & Romagnoli, S.
- Venue
- Critical Care
- Published
- 2020-04-24
- Volume
- 24
- Issue
- 1
- Pages
- 172-172
- ISSN
- 1364-8535 (ISSN-L)
- OpenAlex
- W3020347372
- Cited by
- 214
- References
- 40
- FWCI
- 17.25
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.