The association of tumor-to-background ratios and SUVmax deviations related to point spread function and time-of-flight F18-FDG-PET/CT reconstruction in colorectal liver metastases
Open accessThe DOI matches its Crossref record; 26 of the 27 references it cites were found in a registry or an index.
Abstract
BACKGROUND: The maximum standardized uptake value (SUVmax) is a common clinical parameter for quantification in F18-fluorodeoxyglucose positron emission tomography/computed tomography (FDG-PET/CT), but it is influenced by image reconstruction. The aim of this study was to analyze the association of SUVmax deviations related to point spread function (PSF) and time-of-flight (TOF) reconstruction with tumor-to-background ratios (TBR) in colorectal liver metastases (CRLM). METHODS: Fifteen patients (f, 6; m, 9; median age, 59 years; range, 32 to 72 years) with 28 liver metastases were included retrospectively. FDG-PET/CT imaging (median activity, 237 MBq; range, 231 to 252 MBq; median uptake, 61 min; range, 55 to 67 min) was performed on a Siemens Biograph mCT 64 followed by image reconstruction using 3D-ordered subset expectation maximization (3D-OSEM) or 3D-OSEM with PSF modeling - both with and without TOF information. Differences in SUVmax were analyzed using the Friedman test and Wilcoxon test for paired non-parametric data. The correlation of inter-method differences with the lesions' TBR was studied using Spearman's rank correlation coefficient (rho). Differences between lesions with low (<4.8) and high (>4.8) TBR were analyzed using the Mann-Whitney U test (TBR measured with 3D-OSEM; binarized by its median). RESULTS: There was a significant correlation of the lesions' TBR with relative SUVmax differences related to PSF (PSF + TOF vs. 3D-OSEM + TOF, rho = 0.61; PSF vs. 3D-OSEM, rho = 0.52) or TOF (PSF + TOF vs. PSF, rho = -0.58; 3D-OSEM + TOF vs. 3D-OSEM, rho = -0.61). Accordingly, PSF algorithms only showed higher SUVmax than non-PSF algorithms in lesions with a high TBR (median differences at low/high TBR, +2.6%/+9.1% [PSF + TOF vs. 3D-OSEM + TOF]; +0.7%/+6.4% [PSF vs. 3D-OSEM]). TOF integration also led to higher SUVmax but mainly at low TBR (low/high TBR, +10.4%/+1.8% [PSF + TOF vs. PSF]; +8.6%/-0.1% [3D-OSEM + TOF vs. 3D-OSEM]). CONCLUSIONS: Both PSF and TOF reconstruction resulted in a substantial alteration of SUVmax in CRLM. TOF provided the highest SUVmax increase in low-contrast lesions while - vice versa - PSF showed the most relevant increase in high-contrast lesions. Thus, one should be aware that quantitative analyses of lesions with varying TBR, e.g., in radiotherapy or follow-up studies, may be mainly affected by either PSF or TOF reconstruction, respectively.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures




Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Briefly, TOF increases the lesion’s CR and SUV compared to non-TOF PET at a comparable level of image noise [94,95,96].”
From Influences on PET Quantification and Interpretation (2022) · cites this paper as [95]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“These discrepancies may stem from the fact that the ability of PSF to increase lesion CR is most prominent at the periphery of the transaxial FOV [98,166,167] and in small, high-contrast lesions [95], such as pulmonary nodules.”
From Influences on PET Quantification and Interpretation (2022) · cites this paper as [95]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“This effect is especially prominent in low-contrast lesions [95].”
From Influences on PET Quantification and Interpretation (2022) · cites this paper as [95]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
FDG PET and PET/CT: EANM procedure guidelines for tumour PET imaging: version 1.0
Boellaard, R., O’Doherty, M. J., Weber, W. A., Mottaghy, F. M., Lonsdale, M. N., Stroobants, S. G., Oyen, W. J. G., Kotzerke, J., Hoekstra, O. S., Pruim, J., et al. (2010) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-009-1297-4 · Cited by 1,326 · cited 2×
“However, we refrained from volumetric analyses as such delineation methods may not reflect the clinical practice where more sophisticated algorithms with background correction or manual MTV delineation are required - especially in hepatic lesions [14,25,26].”
MethodSurti, S., Kuhn, A., Werner, M. E., Perkins, A. E., Kolthammer, J. A., & Karp, J. S. (2007) · PubMed · Cited by 639
(2005) · PubMed · Cited by 612
Fully 3-D PET reconstruction with system matrix derived from point source measurements
Panin, V. Y., Kehren, F., Michel, C., & Casey, M. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.876171 · Cited by 536 · cited 1×
“FDG-PET raw data were reconstructed with four algorithms and respective presets provided by the manufacturer: 3D-ordered subset expectation maximization (3D-OSEM; iterations, 2; subsets, 24), 3D-OSEM + time-of-flight analysis (3D-OSEM + TOF; iterations, 2; subsets, 21), iterative reconstruction with systemspecific PSF…”
MethodResolution modeling in PET imaging: Theory, practice, benefits, and pitfalls
Rahmim, A., Qi, J., & Sossi, V. (2013) · Medical Physics · doi:10.1118/1.4800806 · Cited by 357 · cited 1×
“It demonstrated that signal elevations at the spheres’ boundaries (known as Gibbs artifacts [17]) occurred only in PSF + TOF and PSF and only at medium (6:1) and high (16:1) SBR.”
BackgroundVesselle, H. J., Schmidt, R. A., Pugsley, J. M., Li, M., Kohlmyer, S. G., Vallires, E., & Wood, D. E. (2000) · PubMed · Cited by 351
Selzner, M., Hany, T. F., Wildbrett, P., McCormack, L., Kadry, Z., & Clavien, P.-A. (2004) · Annals of Surgery · doi:10.1097/01.sla.0000146145.69835.c5 · Cited by 348
Improvement in Lesion Detection with Whole-Body Oncologic Time-of-Flight PET
El Fakhri, G., Surti, S., Trott, C. M., Scheuermann, J., & Karp, J. S. (2011) · Journal of Nuclear Medicine · doi:10.2967/jnumed.110.080382 · Cited by 198 · cited 1×
“<30) [20].”
The use of 18F-FDG PET/CT in colorectal liver metastases—comparison with CT and liver MRI
Kong, G., Jackson, C., Koh, D., Lewington, V. J., Sharma, B., Brown, G., Cunningham, D., & Cook, G. (2008) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-008-0743-z · Cited by 146
Ramos, C. D., Erdi, Y. E., Gönen, M., Riedel, E., YEUNG, H. W. D., Macapinlac, H. A., Chisin, R., & Larson, S. M. (2001) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s002590000421 · Cited by 139 · cited 1×
“However, FDG-PET quantification is influenced by the reconstruction algorithm used [8,9].”
MethodCheebsumon, P., Yaqub, M., van Velden, F. H. P., Hoekstra, O. S., Lammertsma, A. A., & Boellaard, R. (2011) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-011-1899-5 · Cited by 108 · cited 1×
“However, FDG-PET quantification is influenced by the reconstruction algorithm used [8,9].”
MethodAkamatsu, G., Mitsumoto, K., Taniguchi, T., Tsutsui, Y., Baba, S., & Sasaki, M. (2014) · European Journal of Radiology · doi:10.1016/j.ejrad.2013.09.030 · Cited by 96 · cited 2×
“Again, differences increased with an increasing number of iterations [16].”
BackgroundSchaefferkoetter, J., Casey, M., Townsend, D., & El Fakhri, G. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/5/1465 · Cited by 85 · cited 1×
“60,000 counts) [18].”
The impact of 18F-FDG PET/CT in patients with liver metastases
Chua, S. C., Groves, A. M., Kayani, I. A., Menezes, L., Gacinovic, S., Du, Y., Bomanji, J. B., & Ell, P. J. (2007) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-007-0518-y · Cited by 84
Hendlisz, A., Golfinopoulos, V., Garcia, C., Covas, A., Emonts, P., Ameye, L., Paesmans, M., Deleporte, A., Machiels, G., Toussaint, E., et al. (2011) · Annals of Oncology · doi:10.1093/annonc/mdr554 · Cited by 78 · cited 1×
“Moreover, the maximum standardized uptake value (SUVmax) as a common quantitative measure of the focal FDG uptake may be helpful for therapy response assessment [5] or as a basis for target volume definition in radiotherapy planning [6,7].”
BackgroundImpact of Time-of-Flight and Point-Spread-Function in SUV Quantification for Oncological PET
Prieto, E., Domínguez-Prado, I., García-Velloso, M. J., Peñuelas, I., Richter, J. Á., & Martí-Climent, J. M. (2013) · Clinical Nuclear Medicine · doi:10.1097/rlu.0b013e318279b9df · Cited by 74 · cited 1×
“[10] and Knäusl et al.”
Murray, I., Kalemis, A., Glennon, J., Hasan, S., Quraishi, S., Beyer, T., & Avril, N. E. (2010) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-010-1466-5 · Cited by 60 · cited 1×
“This dependency of TOF-related effects on the lesion volume is in agreement with previous studies showing that the impact of TOF is especially relevant in small lesions [23,24].”
ResultHallett, W. A., Marsden, P. K., Cronin, B. F., & O'Doherty, M. J. (2001) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s002590100561 · Cited by 57 · cited 1×
“It is well known that the TBR is affected by the lesion size due to partial volume effects which are more pronounced in smaller lesions [21,22].”
BackgroundImprovement in PET/CT image quality in overweight patients with PSF and TOF
Taniguchi, T., Akamatsu, G., Kasahara, Y., Mitsumoto, K., Baba, S., Tsutsui, Y., Himuro, K., Mikasa, S., Kidera, D., & Sasaki, M. (2015) · Annals of Nuclear Medicine · doi:10.1007/s12149-014-0912-z · Cited by 53 · cited 1×
“Furthermore, PSF + TOF reduced the CV of the liver in overweight patients (>70 kg) to the CV level in OSEM reconstructed data of normal-weight patients (<70 kg) [19].”
BackgroundRogasch, J. M., Hofheinz, F., Lougovski, A., Furth, C., Ruf, J., Großer, O. S., Mohnike, K., Hass, P., Walke, M., Amthauer, H., et al. (2014) · EJNMMI Physics · doi:10.1186/2197-7364-1-12 · Cited by 53
Self-citationA comparison of diagnostic imaging modalities for colorectal liver metastases
Bonanni, L., Carino, N. D. L., Deshpande, R., Ammori, B. J., Sherlock, D., Valle, J. W., Tam, E., & O'Reilly, D. A. (2014) · European Journal of Surgical Oncology · doi:10.1016/j.ejso.2013.12.023 · Cited by 51 · cited 7×
“Kong G, Jackson C, Koh DM, Lewington V, Sharma B, Brown G, et al. The use of 18 F-FDG PET/CT in colorectal liver metastases - comparison with CT and liver MRI.”
MethodInfluentialBundschuh, R. A., Andratschke, N. H., Dinges, J., Duma, M. N., Astner, S. T., Brügel, M., Ziegler, S. I., Molls, M., Schwaiger, M., & Essler, M. (2012) · Strahlentherapie und Onkologie · doi:10.1007/s00066-012-0094-3 · Cited by 41 · cited 1×
“However, we refrained from volumetric analyses as such delineation methods may not reflect the clinical practice where more sophisticated algorithms with background correction or manual MTV delineation are required - especially in hepatic lesions [14,25,26].”
MethodRausch, I. F., Bergmann, H., Dudczak, R., Hirtl, A., Georg, D., & Knäusl, B. (2013) · Nuklearmedizin · doi:10.3413/nukmed-0523-12-07 · Cited by 35
PET based volume segmentation with emphasis on the iterative TrueX algorithm
Knäusl, B., Hirtl, A., Dobrozemsky, G., Bergmann, H., Kletter, K., Dudczak, R., & Georg, D. (2011) · Zeitschrift für Medizinische Physik · doi:10.1016/j.zemedi.2010.12.003 · Cited by 30 · cited 1×
“[11,12] reported higher SUV and smaller metabolic tumor volumes (MTV) when applying these algorithms compared to common ordered subset expectation maximization (OSEM) algorithms.”
MethodRiou, O., Serrano, B., Azria, D., Paulmier, B., Villeneuve, R., Fenoglietto, P., Artenie, A., Ortholan, C., Faraggi, M., & Thariat, J. (2014) · Radiation Oncology · doi:10.1186/1748-717x-9-127 · Cited by 27 · cited 1×
“Moreover, the maximum standardized uptake value (SUVmax) as a common quantitative measure of the focal FDG uptake may be helpful for therapy response assessment [5] or as a basis for target volume definition in radiotherapy planning [6,7].”
BackgroundParlak, C., Topkan, E., Sönmez, S., Önal, C., & Reyhan, M. (2012) · Japanese Journal of Radiology · doi:10.1007/s11604-012-0101-8 · Cited by 6 · cited 1×
“Moreover, the maximum standardized uptake value (SUVmax) as a common quantitative measure of the focal FDG uptake may be helpful for therapy response assessment [5] or as a basis for target volume definition in radiotherapy planning [6,7].”
Background
Cited by
Quantification, improvement, and harmonization of small lesion detection with state-of-the-art PET
van der Vos, C. S., Koopman, D., Rijnsdorp, S., Arends, A. J., Boellaard, R., van Dalen, J. A., Lubberink, M., Willemsen, A. T. M., & Visser, E. P. (2017) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-017-3727-z · Cited by 206
Rogasch, J. M., Suleiman, S., Hofheinz, F., Bluemel, S., Lukas, M., Amthauer, H., & Furth, C. (2020) · EJNMMI Physics · doi:10.1186/s40658-020-0270-y · Cited by 63
Self-citationMiwa, K., Wagatsuma, K., Nemoto, R., Masubuchi, M., Kamitaka, Y., Yamao, T., Hiratsuka, S., Yamaguchi, M., Yoshii, T., Kobayashi, R., et al. (2020) · Annals of Nuclear Medicine · doi:10.1007/s12149-020-01500-8 · Cited by 59
“1 3 a PET/CT scanner can identify the smallest sub-centimeter sphere is considered to be dependent on the TBR of the sphere [33].”
BackgroundInfluences on PET Quantification and Interpretation
Rogasch, J. M. M., Hofheinz, F., van Heek, L., Voltin, C.-A., Boellaard, R., & Kobe, C. (2022) · Diagnostics · doi:10.3390/diagnostics12020451 · Cited by 57
“This effect is especially prominent in low-contrast lesions [95].”
BackgroundSelf-citationte Riet, J., Rijnsdorp, S., Roef, M. J., & Arends, A. J. (2019) · EJNMMI Physics · doi:10.1186/s40658-019-0262-y · Cited by 46
“Spheres were filled with (18)F-FDG at a 10-to-1 ratio of sphere-to-background, mimicking high intensity (18)F-FDG uptake in clinical studies [26].”
Method
Metadata
- Authors
- Rogasch, J. M., Steffen, I. G., Hofheinz, F., Großer, O. S., Furth, C., Mohnike, K., Hass, P., Walke, M., Apostolova, I., & Amthauer, H.
- Affiliations
- University Hospital Magdeburg (DE)
- Helmholtz-Zentrum Dresden-Rossendorf (DE)
- Universitätsklinik für Strahlentherapie (DE)
- Corresponding author
- Rogasch, Julian MM
- ORCID
- Venue
- EJNMMI Research
- Published
- 2015-05-06
- Volume
- 5
- Issue
- 1
- Pages
- 31-31
- ISSN
- 2191-219X (ISSN-L)
- PMC
- PMC4427576
- OpenAlex
- W2161132469
- Cited by
- 43
- References
- 27
- Citations by year
- 2026: 4 · 2025: 3 · 2024: 6 · 2023: 6 · 2022: 2 · 2021: 8 · 2020: 4 · 2019: 4 · 2018: 2 · 2017: 2 · 2016: 2
- FWCI
- 1.62
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Locations
- EJNMMI Research (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Medical Imaging Techniques and Applications
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Lung Cancer Diagnosis and Treatment
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Cardiac Imaging and Diagnostics
- Keywords
- colorectal liver metastases, tumor-to-background ratio, point spread function, time-of-flight reconstruction, 3D-OSEM, PET attenuation correction
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.