Promise of Wearable Physical Activity Monitors in Oncology Practice
Open accessThe DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Abstract
Commercially available physical activity monitors provide clinicians an opportunity to obtain oncology patient health measures to an unprecedented degree. These devices can provide objective and quantifiable measures of physical activity, which are not subject to errors or bias of self-reporting or shorter duration of formal testing. Prior work on so-called quantified-self data was based on older-generation, research-grade accelerometers, which laid the foundation for consumer-based physical activity monitoring devices to be validated as a feasible and reliable tool in patients with cancer. Physical activity monitors are being used in chronic conditions including chronic obstructive pulmonary disease, congestive heart failure, diabetes mellitus, and obesity. Differing demographics, compounded with higher symptom and treatment burdens in patients with cancer, imply that additional work is needed to understand the unique strengths and weaknesses of physical activity monitors in this population. Oncology programs can systematically implement these tools into their workflows in an adaptable and iterative manner. Translating large amounts of data collected from an individual physical activity monitoring device into clinically relevant information requires sophisticated data compilation and reduction. In this article, we summarize the characteristics of older- and newer-generation physical activity monitors, review the validation of physical activity monitors with respect to health-related quality-of-life assessments, and describe the current role of these devices for the practicing oncologist. We also highlight the challenges and next steps needed for physical activity monitors to provide relevant information that can change the current state of oncology practice.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Moore, M. J., Goldstein, D., Hamm, J., Figer, A., Hecht, J. R., Gallinger, S., Au, H. J., Murawa, P., Walde, D., Wolff, R. A., et al. (2007) · Journal of Clinical Oncology · doi:10.1200/jco.2006.07.9525 · Cited by 3,848
Grothey, A., Cutsem, E. V., Sobrero, A., Siena, S., Falcone, A., Ychou, M., Humblet, Y., Bouché, O., Mineur, L., Barone, C., et al. (2013) · The Lancet · doi:10.1016/s0140-6736(12)61900-x · Cited by 2,895 · cited 1×
“In part because of the lack of accurate assessment of tolerability, some therapies deemed to be effective in clinical trials have not seen broad adoption in clinical practice as a result of poorer-than-expected treatment tolerance in the real world.(18,19) Physical activity monitors may be able to provide a more accur…”
BackgroundNutrition and physical activity guidelines for cancer survivors
Rock, C. L., Doyle, C., Demark‐Wahnefried, W., Meyerhardt, J., Courneya, K. S., Schwartz, A. L., Bandera, E. V., Hamilton, K. K., Grant, B., McCullough, M., et al. (2012) · CA: A Cancer Journal for Clinicians · doi:10.3322/caac.21142 · Cited by 1,995
Brady, M. J., Cella, D. F., Mo, F., Bonomi, A. E., Tulsky, D. S., Lloyd, S. R., Deasy, S., Cobleigh, M., & Shiomoto, G. (1997) · Journal of Clinical Oncology · doi:10.1200/jco.1997.15.3.974 · Cited by 1,752
Arem, H., Moore, S. C., Patel, A., Hartge, P., Berrington de Gonzalez, A., Visvanathan, K., Campbell, P. T., Freedman, M., Weiderpass, E., Adami, H. O., et al. (2015) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2015.0533 · Cited by 1,498 · cited 1×
“Higher levels of physical activity have been reported to decrease both cancer mortality and recurrence rates.(25) Physical activity monitors can also increase levels of physical activity among patients with cancer (Fig 1).”
BackgroundBest Practices for Using Physical Activity Monitors in Population-Based Research
MATTHEWS, C. E., HAGSTRÖMER, M., POBER, D. M., & BOWLES, H. R. (2012) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3182399e5b · Cited by 703 · cited 2×
“Modern physical activity monitors provide measures beyond step count, such as variability, minutes and intensity of activity, energy expenditure, and posture (eg, hours spent sitting, standing, or lying down per day).(2) Recent studies have shown that sedentary behavior can influence health significantly, and measures…”
BackgroundSanta Mina, D., Clarke, H., Ritvo, P., Leung, Y. W., Matthew, A. G., Katz, J., Trachtenberg, J., & Alibhai, S. M. H. (2014) · Physiotherapy · doi:10.1016/j.physio.2013.08.008 · Cited by 424
Fitbit®: An accurate and reliable device for wireless physical activity tracking
Diaz, K. M., Krupka, D. J., Chang, M. J., Peacock, J., Ma, Y., Goldsmith, J., Schwartz, J. E., & Davidson, K. W. (2015) · International Journal of Cardiology · doi:10.1016/j.ijcard.2015.03.038 · Cited by 405
Wang, J. B., Cadmus-Bertram, L. A., Natarajan, L., White, M. M., Madanat, H., Nichols, J. F., Ayala, G. X., & Pierce, J. P. (2015) · Telemedicine and e-Health · doi:10.1089/tmj.2014.0176 · Cited by 308
Movement toward a novel activity monitoring device
Montgomery-Downs, H. E., Insana, S. P., & Bond, J. A. (2012) · Sleep and Breathing · doi:10.1007/s11325-011-0585-y · Cited by 301 · cited 1×
“Heart rate and sleep measurements are newer concepts that are being standardized.(6,9) Depending on the objectiveof incorporatingphysical activitymonitors intoclinicor research processes, some devices may therefore be better suited than others, and understanding those nuances is critical before implementation.”
Background
Cited by
Artificial intelligence for clinical oncology
Kann, B. H., Hosny, A., & Aerts, H. J. W. L. (2021) · Cancer Cell · doi:10.1016/j.ccell.2021.04.002 · Cited by 370
Wearable devices in clinical trials: hype and hypothesis
Izmailova, E. S., Wagner, J. A., & Perakslis, E. D. (2018) · Clinical Pharmacology & Therapeutics · doi:10.1002/cpt.966 · Cited by 265
Mapping and Taking Stock of the Personal Informatics Literature
Epstein, D. A., Caldeira, C., Figueiredo, M. C., Lu, X., Silva, L. M., Williams, L., Lee, J. H., Li, Q., Ahuja, S., Chen, Q., et al. (2020) · Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies · doi:10.1145/3432231 · Cited by 218
“what data they find relevant, accurate, or worth collecting [15,21,150] and how that data should be used in consultations [8,45].”
BackgroundThe Future of Wearable Technologies and Remote Monitoring in Health Care
Liao, Y., Thompson, C., Peterson, S., Mandrola, J., & Beg, M. S. (2019) · American Society of Clinical Oncology Educational Book · doi:10.1200/edbk_238919 · Cited by 178
“The availability and widespread adoption of wearable physical activity monitors improves the ability to quantify physical activity in oncology care 16 .”
BackgroundSelf-citationHarnessing consumer smartphone and wearable sensors for clinical cancer research
Low, C. A. (2020) · npj Digital Medicine · doi:10.1038/s41746-020-00351-x · Cited by 120
The Use of Wearables in Clinical Trials During Cancer Treatment: Systematic Review
Beauchamp, U. L., Pappot, H., & Holländer-Mieritz, C. (2020) · JMIR mHealth and uHealth · doi:10.2196/22006 · Cited by 110
The Use of Wearable Devices in Oncology Patients: A Systematic Review
Chow, R., Drkulec, H., Im, J. H. B., Tsai, J., Nafees, A., Kumar, S., Hou, T., Fazelzad, R., Leighl, N. B., Krzyzanowska, M., et al. (2024) · The Oncologist · doi:10.1093/oncolo/oyad305 · Cited by 85
Lynch, C., Bird, S., Lythgo, N., & Selva-Raj, I. (2020) · American Journal of Health Promotion · doi:10.1177/0890117119895204 · Cited by 58
Patients' perspective on digital technologies in advanced genitourinary cancers
Rodler, S., Buchner, A., Stief, C. G., Heinemann, V., Staehler, M., & Casuscelli, J. (2021) · Clinical Genitourinary Cancer · doi:10.1016/j.clgc.2020.03.018 · Cited by 27
Metadata
- Authors
- Beg, M. S., Gupta, A., Stewart, T., & Rethorst, C. D.
- Venue
- Journal of Oncology Practice
- Published
- 2017-02
- Volume
- 13
- Issue
- 2
- Pages
- 82-89
- ISSN
- 1554-7477 (ISSN-L)
- 1935-469X
- OpenAlex
- W2588852707
- Cited by
- 86
- References
- 16
- FWCI
- 6.35
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.