Nephrotoxicity and Kidney Transport Assessment on 3D Perfused Proximal Tubules
Open accessThe DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
Proximal tubules in the kidney play a crucial role in reabsorbing and eliminating substrates from the body into the urine, leading to high local concentrations of xenobiotics. This makes the proximal tubule a major target for drug toxicity that needs to be evaluated during the drug development process. Here, we describe an advanced in vitro model consisting of fully polarized renal proximal tubular epithelial cells cultured in a microfluidic system. Up to 40 leak-tight tubules were cultured on this platform that provides access to the basolateral as well as the apical side of the epithelial cells. Exposure to the nephrotoxicant cisplatin caused a dose-dependent disruption of the epithelial barrier, a decrease in viability, an increase in effluent LDH activity, and changes in expression of tight-junction marker zona-occludence 1, actin, and DNA-damage marker H2A.X, as detected by immunostaining. Activity and inhibition of the efflux pumps P-glycoprotein (P-gp) and multidrug resistance protein (MRP) were demonstrated using fluorescence-based transporter assays. In addition, the transepithelial transport function from the basolateral to the apical side of the proximal tubule was studied. The apparent permeability of the fluorescent P-gp substrate rhodamine 123 was decreased by 35% by co-incubation with cyclosporin A. Furthermore, the activity of the glucose transporter SGLT2 was demonstrated using the fluorescent glucose analog 6-NBDG which was sensitive to inhibition by phlorizin. Our results demonstrate that we developed a functional 3D perfused proximal tubule model with advanced renal epithelial characteristics that can be used for drug screening studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Membrane transporters in drug development
The International Transporter Consortium, Giacomini, K. M., Huang, S.-M., Tweedie, D. J., Benet, L. Z., Brouwer, K. L. R., Chu, X., Dahlin, A., Evers, R., Fischer, V., et al. (2010) · Nature Reviews Drug Discovery · doi:10.1038/nrd3028 · Cited by 3,340
Glucose transporters (GLUT and SGLT): expanded families of sugar transport proteins
Wood, I. S., & Trayhurn, P. (2003) · British Journal of Nutrition · doi:10.1079/bjn2002763 · Cited by 889
Bioprinting of 3D convoluted renal proximal tubules on perfusable chips
Homan, K. A., Kolesky, D. B., Skylar-Scott, M. A., Herrmann, J., Obuobi, H., Moisan, A., & Lewis, J. A. (2016) · Scientific Reports · doi:10.1038/srep34845 · Cited by 699
Small molecule absorption by PDMS in the context of drug response bioassays
van Meer, B. J., de Vries, H., Firth, K. S. A., van Weerd, J., Tertoolen, L. G. J., Karperien, H. B. J., Jonkheijm, P., Denning, C., IJzerman, A. P., & Mummery, C. L. (2017) · Biochemical and Biophysical Research Communications · doi:10.1016/j.bbrc.2016.11.062 · Cited by 502
Microfluidic 3D cell culture: from tools to tissue models
van Duinen, V., Trietsch, S. J., Joore, J., Vulto, P., & Hankemeier, T. (2015) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2015.05.002 · Cited by 500
Self-citationKidney-on-a-Chip technology for drug-induced nephrotoxicity screening
Wilmer, M. J., Ng, C. P., Lanz, H. L., Vulto, P., Suter-Dick, L., & Masereeuw, R. (2016) · Trends in Biotechnology · doi:10.1016/j.tibtech.2015.11.001 · Cited by 354
Self-citationTrietsch, S. J., Naumovska, E., Kurek, D., Setyawati, M. C., Vormann, M. K., Wilschut, K. J., Lanz, H. L., Nicolas, A., Ng, C. P., Joore, J., et al. (2017) · Nature Communications · doi:10.1038/s41467-017-00259-3 · Cited by 290
Self-citationMicrofluidic titer plate for stratified 3D cell culture
Trietsch, S. J., Israëls, G. D., Joore, J., Hankemeier, T., & Vulto, P. (2013) · Lab on a Chip · doi:10.1039/c3lc50210d · Cited by 189
Self-citationTherapy response testing of breast cancer in a 3D high-throughput perfused microfluidic platform
Lanz, H. L., Saleh, A., Kramer, B., Cairns, J., Ng, C. P., Yu, J., Trietsch, S. J., Hankemeier, T., Joore, J., Vulto, P., et al. (2017) · BMC Cancer · doi:10.1186/s12885-017-3709-3 · Cited by 135
Self-citation
Cited by
Davies, M., Jones, R. D. O., Grime, K., Jansson-Löfmark, R., Fretland, A. J., Winiwarter, S., Morgan, P., & McGinnity, D. F. (2020) · Trends in Pharmacological Sciences · doi:10.1016/j.tips.2020.03.004 · Cited by 123
Human Organoids for Predictive Toxicology Research and Drug Development
Matsui, T., & Shinozawa, T. (2021) · Frontiers in Genetics · doi:10.3389/fgene.2021.767621 · Cited by 109
Vormann, M. K., Tool, L. M., Ohbuchi, M., Gijzen, L., van Vught, R., Hankemeier, T., Kiyonaga, F., Kawabe, T., Goto, T., Fujimori, A., et al. (2022) · Kidney360 · doi:10.34067/kid.0003622021 · Cited by 39
“The plate was thereafter fixated as described previously (26), and nuclei were stained with Hoechst 33342 and imaged again for DAPI.”
BackgroundMethodSelf-citation
Metadata
- Authors
- Vormann, M. K., Gijzen, L., Hutter, S., Boot, L., Nicolas, A., van den Heuvel, A., Vriend, J., Ng, C. P., Nieskens, T. T. G., van Duinen, V., de Wagenaar, B., Masereeuw, R., Suter-Dick, L., Trietsch, S. J., Wilmer, M., Joore, J., Vulto, P., & Lanz, H. L.
- Venue
- The AAPS Journal
- Published
- 2018-08-14
- Volume
- 20
- Issue
- 5
- Pages
- 90-90
- ISSN
- 1550-7416 (ISSN-L)
- OpenAlex
- W2885232549
- Cited by
- 131
- References
- 9
- FWCI
- 4.63
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Nephrotoxicity and Kidney Transport Assessment on 3D Perfused Proximal Tubules. https://app.cochat.ai/papers/10.1208/s12248-018-0248-z
- The paper
- Vormann, M. K., Gijzen, L., Hutter, S., Boot, L., Nicolas, A., van den Heuvel, A., Vriend, J., Ng, C. P., Nieskens, T. T. G., van Duinen, V., de Wagenaar, B., Masereeuw, R., Suter-Dick, L., Trietsch, S. J., Wilmer, M., Joore, J., Vulto, P., & Lanz, H. L. (2018). Nephrotoxicity and Kidney Transport Assessment on 3D Perfused Proximal Tubules. The AAPS Journal. https://doi.org/10.1208/s12248-018-0248-z
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.