The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
High-accuracy measurement of the 87 Rb ground-state hyperfine splitting in an atomic fountain
Open accessAbstract
We describe the operation of a laser-cooled rubidium 87 Rb frequency standard. We present a new measurement of the 87 Rb hyperfine frequency with a 1.3 × 10 −14 relative accuracy, by comparison with a Cs fountain primary standard. The measured 87 Rb ground-state hyperfine splitting is ν 87 = 6 834 682 610.90429(9) Hz. This value differs from previously published values (see Essen L., Hope E. G. and Sutcliffe D., Nature 189 1961 298; Penselin S., Moran T., Cohen W. and Wscinkler G., Phys. Rev. 127 1962 524; Arditi M. and Cerez P. IEEE Trans. Instrum. Meas. IM-21 1972 391) by about 2 − 3 Hz and is 10 4 times more accurate. Because of the low collisional shift in 87 Rb, future improvements may lead to a stability of 1 × 10 −14 τ −1/2 and a relative accuracy in the 10 −17 range.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Quantum projection noise: Population fluctuations in two-level systems
Itano, W. M., Bergquist, J. C., Bollinger, J. J., Gilligan, J. M., Heinzen, D. J., Moore, F. L., Raizen, M. G., & Wineland, D. J. (1993) · Physical Review A · doi:10.1103/physreva.47.3554 · Cited by 613
Cited by
Quantum Projection Noise in an Atomic Fountain: A High Stability Cesium Frequency Standard
Santarelli, G., Laurent, P., Lemonde, P., Clairon, A., Mann, A. G., Chang, S., Luiten, A. N., & Salomon, C. (1999) · Physical Review Letters · doi:10.1103/physrevlett.82.4619 · Cited by 569
Self-citationSoffel, M., Klioner, S. A., Petit, G., Wolf, P., Kopeikin, S. M., Bretagnon, P., Brumberg, V. A., Capitaine, N., Damour, T., Fukushima, T., et al. (2003) · The Astronomical Journal · doi:10.1086/378162 · Cited by 392
Wynands, R., & Weyers, S. (2005) · Metrologia · doi:10.1088/0026-1394/42/3/s08 · Cited by 374
Atomic gravitational wave interferometric sensor
Dimopoulos, S., Graham, P. W., Hogan, J. M., Kasevich, M. A., & Rajendran, S. (2008) · Physical Review D · doi:10.1103/physrevd.78.122002 · Cited by 335
Search for Variations of Fundamental Constants using Atomic Fountain Clocks
Marion, H., Pereira Dos Santos, F., Abgrall, M., Zhang, S., Sortais, Y., Bize, S., Maksimovic, I., Calonico, D., Grünert, J., Mandache, C., et al. (2003) · Physical Review Letters · doi:10.1103/physrevlett.90.150801 · Cited by 298
Self-citation
Metadata
- Authors
- Bize, S., Sortais, Y., Santos, M. S., Mandache, C., Clairon, A., & Salomon, C.
- Venue
- Europhysics Letters (EPL)
- Publisher
- IOP Publishing
- Published
- 1999-03-01
- Volume
- 45
- Issue
- 5
- Pages
- 558-564
- ISSN
- 0295-5075 (ISSN-L)
- 1286-4854
- OpenAlex
- W2052617183
- Cited by
- 162
- References
- 1
- FWCI
- 4.94
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: High-accuracy measurement of the 87 Rb ground-state hyperfine splitting in an atomic fountain. https://app.cochat.ai/papers/10.1209/epl/i1999-00203-9
- The paper
- Bize, S., Sortais, Y., Santos, M. S., Mandache, C., Clairon, A., & Salomon, C. (1999). High-accuracy measurement of the 87 Rb ground-state hyperfine splitting in an atomic fountain. Europhysics Letters (EPL). https://doi.org/10.1209/epl/i1999-00203-9
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.