CoChat

Eight-Point Glucose Testing Versus the Continuous Glucose Monitoring System in Evaluation of Glycemic Control in Type 1 Diabetes

· 2005 · The Journal of Clinical Endocrinology & Metabolism
Cited by 88

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

Context: Advantages/disadvantages of continuous vs. discrete glucose monitoring are not well documented. Objective: Compare glucose profiles from home meters vs. continuous sensors. Design: Randomized clinical trial conducted by the Diabetes Research in Children Network (DirecNet) to assess the utility of the GlucoWatch G2 Biographer. Setting: Home glucose measurements. Patients: Two hundred children (age, 7 to < 18 yr) with type 1 diabetes. Intervention: At baseline, subjects were asked to wear the continuous glucose monitoring system (CGMS) sensor and perform meter tests at eight prespecified times of the day (eight-point testing) each for 3 d (2 d using both, 1 d eight-point testing only, 1 d CGMS only). Hemoglobin A1c was measured in a central laboratory. Main Outcome Measure: Six-month hemoglobin A1c. This analysis looked at baseline glucose profiles/hemoglobin A1c. Results: Only 10% of subjects completed full eight-point testing for 3 d, but median CGMS use was 70 h. Mean glucose was lower when measured by the CGMS compared with eight-point testing (183 ± 37 vs. 188 ± 41 mg/dl; 10.2 ± 2.1 vs.10.4 ± 2.3 mmol/liter; P = 0.009), especially overnight (2400–0400 h; 174 vs. 199 mg/dl; 9.7 vs. 11.1 mmol/liter; P < 0.001). Associations of hemoglobin A1c with mean glucose were similar for eight-point testing [slope 23 mg/dl per 1% (1.3 mmol/liter); correlation 0.40; P < 0.001] and CGMS [slope 19 mg/dl per 1% (1.1 mmol/liter); correlation 0.39; P < 0.001]. Postprandial excursions were lower for eight-point testing vs. CGMS, especially after dinner (mean excursion −17 vs. 63 mg/dl; −1.0 vs. 3.5 mmol/liter; P < 0.001). Conclusions: Both methods gave similar mean glucose profiles and associations with hemoglobin A1c. Advantages of the CGMS were higher density of data and better detection of postprandial peaks. However, the CGMS may overestimate the frequency of low glucose levels, especially overnight.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1210/jc.2004-2510

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Venue
The Journal of Clinical Endocrinology & Metabolism
Published
2005-06-01
Volume
90
Issue
6
Pages
3387-3391
ISSN
  • 0021-972X (ISSN-L)
  • 1945-7197
OpenAlex
W163234383
Cited by
88
References
4
FWCI
5.47
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.