CoChat

Comparison of Adrenocorticotropin (ACTH) Stimulation Tests and Insulin Hypoglycemia in Normal Humans: Low Dose, Standard High Dose, and 8-Hour ACTH-(1–24) Infusion Tests1

Nye, Elisabeth J., Grice, Jeffrey E., Hockings, Gregory I., Strakosch, Christopher R., Crosbie, Georgina V., Walters, Margaret M., Jackson, Richard V. · 1999 · The Journal of Clinical Endocrinology & Metabolism
Cited by 83

The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.

Abstract

The efficacy of the standard high dose ACTH stimulation test (HDT), using a pharmacological 250-microg dose of synthetic ACTH-(1-24), in the diagnosis of central hypoadrenalism is controversial. The insulin hypoglycemia test is widely regarded as the gold standard dynamic stimulation test of the hypothalamo-pituitary-adrenal (HPA) axis that provides the most reliable assessment of HPA axis integrity and reserve. Alternatively, a prolonged infusion of ACTH causes a continuing rise in plasma cortisol levels that may predict the adrenals' capacity to respond to severe ongoing stress. In nine normal subjects, we compared plasma ACTH and cortisol levels produced by three i.v. bolus low doses of ACTH-(1-24) (0.1, 0.5, and 1.0 microg/1.73 m2; LDTs) with those stimulated by hypoglycemia (0.15 U/kg insulin) and with the cortisol response to a standard 250-microg dose of ACTH-(1-24). The normal cortisol response to an 8-h ACTH-(1-24) infusion (250 microg at a constant rate over 8 h) was determined using three modern cortisol assays: a high pressure liquid chromatography method (HPLC), a fluorescence polarization immunoassay (FPIA), and a standard RIA. In the LDTs, stepwise increases in mean peak plasma ACTH were observed (12.4 +/- 2.0, 48.2 +/- 7.2, 120.2 +/- 15.5 pmol/L for the 0.1-, 0.5-, and 1.0-microg LDTs, respectively; P values all <0.0022 when comparing peak values between tests). The peak plasma ACTH level after insulin-induced hypoglycemia was significantly lower than that produced in the 1.0-microg LDT (69.6 +/- 9.3 vs. 120.2 +/- 15.5 pmol/L; P < 0.0002), but was higher than that obtained during the 0.5-microg LDT (69.6 +/- 9.3 vs. 48.2 +/- 7.2 pmol/L; P < 0.02). In the LDTs, statistically different, dose-dependent increases in peak cortisol concentration occurred (355 +/- 16, 432 +/- 13, and 482 +/- 23 nmol/L; greatest P value is 0.0283 for comparisons between all tests). The peak cortisol levels achieved during the LDTs were very different from those during the HDT (mean peak cortisol, 580 +/- 27 nmol/L; all P values <0.00009. However, the mean 30 min response in the 1.0-microg LDT did not differ from that in the HDT (471 +/- 22 vs. 492 +/- 22 nmol/L; P = 0.2). In the 8-h ACTH infusion test, plasma cortisol concentrations progressively increased, reaching peak levels much higher than those in the HDT [995 +/- 50 vs. 580 +/- 27 nmol/L (HPLC) and 1326 +/- 100 vs 759 +/- 31 nmol/L (FPIA)]. Significant differences in the basal, 1 h, and peak cortisol levels as determined by the three different assay methods (HPLC, FPIA, and RIA) were observed in the 8-h infusion tests. Similarly, in the HDTs there were significant differences in the mean 30 and 60 min cortisol levels as measured by HPLC compared with those determined by FPIA. We conclude that up to 30 min postinjection, 1.0 microg/1.73 m2 ACTH-(1-24) stimulates maximal adrenocortical secretion. Similar lower normal limits at 30 min may be applied in the 1.0-microg LDT and the HDT, but not when lower doses of ACTH-(1-24) are administered. The peak plasma ACTH level produced in the 1.0-microg LDT is higher than in the insulin hypoglycemia test, but is of the same order of magnitude. The peak cortisol concentration obtained during an 8-h synthetic ACTH-(1-24) infusion is considerably higher than that stimulated by a standard bolus 250-microg dose, potentially providing a means of evaluating the adrenocortical capacity to maintain maximal cortisol secretion. Appropriate interpretation of any of these tests of HPA axis function relies on the accurate determination of normal response ranges, which may vary significantly depending on the cortisol assay used.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1210/jcem.84.10.6062

Cites

13 of 13 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 13 references

Cited by

See all 83

Metadata

Authors
Nye, E. J., Grice, J. E., Hockings, G. I., Strakosch, C. R., Crosbie, G. V., Walters, M. M., & Jackson, R. V.
Venue
The Journal of Clinical Endocrinology & Metabolism
Published
1999-10
Volume
84
Issue
10
Pages
3648-3655
ISSN
  • 0021-972X (ISSN-L)
  • 1945-7197
OpenAlex
W2053276613
Cited by
83
References
13
FWCI
1.91
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparison of Adrenocorticotropin (ACTH) Stimulation Tests and Insulin Hypoglycemia in Normal Humans: Low Dose, Standard High Dose, and 8-Hour ACTH-(1–24) Infusion Tests1. https://app.cochat.ai/papers/10.1210/jcem.84.10.6062
The paper
Nye, E. J., Grice, J. E., Hockings, G. I., Strakosch, C. R., Crosbie, G. V., Walters, M. M., & Jackson, R. V. (1999). Comparison of Adrenocorticotropin (ACTH) Stimulation Tests and Insulin Hypoglycemia in Normal Humans: Low Dose, Standard High Dose, and 8-Hour ACTH-(1–24) Infusion Tests1. The Journal of Clinical Endocrinology & Metabolism. https://doi.org/10.1210/jcem.84.10.6062

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.