Independent home use of a brain-computer interface by people with amyotrophic lateral sclerosis
Open accessThe DOI matches its Crossref record; 44 of the 45 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To assess the reliability and usefulness of an EEG-based brain-computer interface (BCI) for patients with advanced amyotrophic lateral sclerosis (ALS) who used it independently at home for up to 18 months. METHODS: Of 42 patients consented, 39 (93%) met the study criteria, and 37 (88%) were assessed for use of the Wadsworth BCI. Nine (21%) could not use the BCI. Of the other 28, 27 (men, age 28-79 years) (64%) had the BCI placed in their homes, and they and their caregivers were trained to use it. Use data were collected by Internet. Periodic visits evaluated BCI benefit and burden and quality of life. RESULTS: Over subsequent months, 12 (29% of the original 42) left the study because of death or rapid disease progression and 6 (14%) left because of decreased interest. Fourteen (33%) completed training and used the BCI independently, mainly for communication. Technical problems were rare. Patient and caregiver ratings indicated that BCI benefit exceeded burden. Quality of life remained stable. Of those not lost to the disease, half completed the study; all but 1 patient kept the BCI for further use. CONCLUSION: The Wadsworth BCI home system can function reliably and usefully when operated by patients in their homes. BCIs that support communication are at present most suitable for people who are severely disabled but are otherwise in stable health. Improvements in BCI convenience and performance, including some now underway, should increase the number of people who find them useful and the extent to which they are used.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“EEG spellers based on oddball potentials or motor imagery typically achieve 1–5 characters per minute28–32.”
From High-performance brain-to-text communication via handwriting (2021) · cites this paper as [32]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
1 retracted
Brain–computer interface–based communication in the completely locked-in State
Chaudhary, U., Xia, B., Silvoni, S., Cohen, L. G., & Birbaumer, N. (2017) · PLOS Biology · doi:10.1371/journal.pbio.1002593 · Cited by 235
RetractedEl Escorial revisited: revised criteria for the diagnosis of amyotrophic lateral sclerosis
Brooks, B. R., Miller, R. G., Swash, M., & Munsat, T. L. (2000) · Amyotrophic Lateral Sclerosis and Other Motor Neuron Disorders · doi:10.1080/146608200300079536 · Cited by 5,433
Cedarbaum, J. M., Stambler, N., Malta, E., Fuller, C., Hilt, D., Thurmond, B., & Nakanishi, A. (1999) · Journal of the Neurological Sciences · doi:10.1016/s0022-510x(99)00210-5 · Cited by 3,307
Farwell, L. A., & Donchin, E. (1988) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(88)90149-6 · Cited by 3,228 · cited 1×
“Thus, BCIs that can preserve communication might affect clinical recommendations and patient decisions.(1,11,12)”
BackgroundBCI2000: A General-Purpose Brain-Computer Interface (BCI) System
Schalk, G., McFarland, D. J., Hinterberger, T., Birbaumer, N., & Wolpaw, J. R. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.827072 · Cited by 3,024
Self-citationA spelling device for the paralysed
Birbaumer, N., Ghanayim, N., Hinterberger, T., Iversen, I., Kotchoubey, B., Kübler, A., Perelmouter, J., Taub, E., & Flor, H. (1999) · Nature · doi:10.1038/18581 · Cited by 1,577
Brain–Computer InterfacesPrinciples and Practice
Wolpaw, J., & Wolpaw, E. W. (2012) · Oxford University Press eBooks · doi:10.1093/acprof:oso/9780195388855.001.0001 · Cited by 1,104
Self-citationAmerican Electroencephalographic Society Guidelines for Standard Electrode Position Nomenclature
&NA; (1991) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199104000-00007 · Cited by 1,050
Brain–computer interfaces for communication and rehabilitation
Chaudhary, U., Birbaumer, N., & Ramos-Murguialday, A. (2016) · Nature Reviews Neurology · doi:10.1038/nrneurol.2016.113 · Cited by 928
American Electroencephalographic Society guidelines for standard electrode position nomenclature
Sharbrough, F. W. (1991) · Journal of Clinical Neurophysiology · Cited by 918
Toward enhanced p300 speller performance
Krusienski, D. J., Sellers, E. W., McFarland, D. J., Vaughan, T. M., & Wolpaw, J. R. (2008) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2007.07.017 · Cited by 749
Self-citationThe Intention-to-Treat Principle: How to Assess the True Effect of Choosing a Medical Treatment
Detry, M. A., & Lewis, R. J. (2014) · JAMA · doi:10.1001/jama.2014.7523 · Cited by 634
Fully Implanted Brain–Computer Interface in a Locked-In Patient with ALS
Vansteensel, M. J., Pels, E. G. M., Bleichner, M. G., Branco, M. P., Denison, T., Freudenburg, Z. V., Gosselaar, P., Leinders, S., Ottens, T. H., Van Den Boom, M. A., et al. (2016) · New England Journal of Medicine · doi:10.1056/nejmoa1608085 · Cited by 578
Sellers, E. W., Krusienski, D. J., McFarland, D. J., Vaughan, T. M., & Wolpaw, J. R. (2006) · Biological Psychology · doi:10.1016/j.biopsycho.2006.04.007 · Cited by 501
Self-citationRobin Cohen, S., Mount, B. M., Bruera, E., Provost, M., Rowe, J., & Tong, K. (1997) · Palliative Medicine · doi:10.1177/026921639701100102 · Cited by 436
A brain-computer interface for long-term independent home use
Sellers, E. W., Vaughan, T. M., & Wolpaw, J. R. (2010) · Amyotrophic Lateral Sclerosis · doi:10.3109/17482961003777470 · Cited by 400
Self-citationFlashing characters with famous faces improves ERP-based brain–computer interface performance
Kaufmann, T., Schulz, S. M., Grünzinger, C., & Kübler, A. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/5/056016 · Cited by 300
Quality of life in ALS is maintained as physical function declines
Robbins, R. A., Simmons, Z., Bremer, B. A., Walsh, S. M., & Fischer, S. (2001) · Neurology · doi:10.1212/wnl.56.4.442 · Cited by 245
A Practical Guide to Brain–Computer Interfacing with BCI2000
Schalk, G., & Mellinger, J. (2010) · Springer eBooks · doi:10.1007/978-1-84996-092-2 · Cited by 216
Brain–Computer Interfaces: Something New under the Sun
Wolpaw, J. R., & Winter Wolpaw, E. (2012) · Brain–Computer InterfacesPrinciples and Practice · doi:10.1093/acprof:oso/9780195388855.003.0001 · Cited by 196 · cited 2×
“, EEG activity) rather than muscles.(1) The principal rationale for their development has been that BCIs could restore communication and control to people with severe neuromuscular disabilities.”
BackgroundSelf-citationComparison of Dry and Gel Based Electrodes for P300 Brain–Computer Interfaces
Guger, C., Krausz, G., Allison, B. Z., & Edlinger, G. (2012) · Frontiers in Neuroscience · doi:10.3389/fnins.2012.00060 · Cited by 190
Moss, A. H., Casey, P., Stocking, C. B., Roos, R. P., Brooks, B. R., & Siegler, M. (1993) · Neurology · doi:10.1212/wnl.43.2.438 · Cited by 177
Patients With Amyotrophic Lateral Sclerosis Receiving Long-term Mechanical Ventilation
Moss, A. H., Oppenheimer, E. A., Casey, P., Cazzolli, P. A., Roos, R. P., Stocking, C. B., & Siegler, M. (1996) · Chest · doi:10.1378/chest.110.1.249 · Cited by 173
Holz, E. M., Botrel, L., Kaufmann, T., & Kübler, A. (2015) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2014.03.035 · Cited by 171
A new EEG recording system for passive dry electrodes
Gargiulo, G., Calvo, R. A., Bifulco, P., Cesarelli, M., Jin, C., Mohamed, A., & van Schaik, A. (2010) · Clinical Neurophysiology · doi:10.1016/j.clinph.2009.12.025 · Cited by 165 · cited 4×
“Advances now underway such as dryelectrode technology, telemetry, and improved portability would reduce these requirements and could thereby increase the ease and convenience of BCI use and decrease the interruptions caused by acute illnesses or other life events.(30,31) The need for an SA willing and able to support…”
BackgroundInfluentialScherer, M. J. (2002) · Disability and Rehabilitation · doi:10.1080/09638280110066262 · Cited by 164 · cited 1×
“These are essential if a BCI, or any assistive technology, is to be both useful and actually used.(35) Unlike other therapies (e.”
BackgroundListen, You are Writing! Speeding up Online Spelling with a Dynamic Auditory BCI
Schreuder, M., Rost, T., & Tangermann, M. (2011) · Frontiers in Neuroscience · doi:10.3389/fnins.2011.00112 · Cited by 150
Brain-computer interface (BCI) evaluation in people with amyotrophic lateral sclerosis
McCane, L. M., Sellers, E. W., McFarland, D. J., Mak, J. N., Carmack, C. S., Zeitlin, D., Wolpaw, J. R., & Vaughan, T. M. (2014) · Amyotrophic Lateral Sclerosis and Frontotemporal Degeneration · doi:10.3109/21678421.2013.865750 · Cited by 129 · cited 3×
“These studies generated substantial expectations for the clinical value of BCIs.”
BackgroundSelf-citationAssessment of brain–machine interfaces from the perspective of people with paralysis
Blabe, C. H., Gilja, V., Chestek, C. A., Shenoy, K. V., Anderson, K. D., & Henderson, J. M. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/4/043002 · Cited by 121
Depression and Quality of Life in Patients With Amyotrophic Lateral Sclerosis
Lulé, D., Häcker, S., Ludolph, A., Birbaumer, N., & Kübler, A. (2008) · Deutsches Ärzteblatt international · doi:10.3238/arztebl.2008.0397 · Cited by 112
Körner, S., Siniawski, M., Kollewe, K., Rath, K. J., Krampfl, K., Zapf, A., Dengler, R., & Petri, S. (2012) · Amyotrophic Lateral Sclerosis and Frontotemporal Degeneration · doi:10.3109/17482968.2012.692382 · Cited by 86
Requests for euthanasia: origin of suffering in ALS, heart failure, and cancer patients
Maessen, M., Veldink, J. H., van den Berg, L. H., Schouten, H. J., van der Wal, G., & Onwuteaka-Philipsen, B. D. (2010) · Journal of Neurology · doi:10.1007/s00415-010-5474-y · Cited by 85
A practical, intuitive brain–computer interface for communicating ‘yes’ or ‘no’ by listening
Hill, N. J., Ricci, E., Haider, S., McCane, L. M., Heckman, S., Wolpaw, J. R., & Vaughan, T. M. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/3/035003 · Cited by 67
Self-citationThe National Registry of Veterans with Amyotrophic Lateral Sclerosis
Allen, K. D., Kasarskis, E. J., Bedlack, R. S., Rozear, M. P., Morgenlander, J. C., Sabet, A., Sams, L., Lindquist, J. H., Harrelson, M. L., Coffman, C. J., et al. (2008) · Neuroepidemiology · doi:10.1159/000126910 · Cited by 52
Self-citationEye‐tracking–based assessment suggests preserved well‐being in locked‐in patients
Linse, K., Rüger, W., Joos, M., Schmitz‐Peiffer, H., Storch, A., & Hermann, A. (2017) · Annals of Neurology · doi:10.1002/ana.24871 · Cited by 51
Interfacing brain with computer to improve communication and rehabilitation after brain damage
Riccio, A., Pichiorri, F., Schettini, F., Toppi, J., Risetti, M., Formisano, R., Molinari, M., Astolfi, L., Cincotti, F., & Mattia, D. (2016) · Progress in brain research · doi:10.1016/bs.pbr.2016.04.018 · Cited by 43
Evaluation of Quality of Life in Complete Locked-In Syndrome Patients
Rousseau, M.-C., Pietra, S., Nadji, M., & Billette de Villemeur, T. (2013) · Journal of Palliative Medicine · doi:10.1089/jpm.2013.0120 · Cited by 40
BCIs That Use P300 Event-Related Potentials
Sellers, E. W., Arbel, Y., & Donchin, E. (2012) · Brain–Computer InterfacesPrinciples and Practice · doi:10.1093/acprof:oso/9780195388855.003.0012 · Cited by 37
Self-citationNelson, K., Sun, H., Dolan, E., Maynard, C., Beste, L., Bryson, C., Schectman, G., & Fihn, S. D. (2014) · Journal of Ambulatory Care Management · doi:10.1097/jac.0000000000000032 · Cited by 35 · cited 1×
“These issues were addressed in the context of the US Department of Veterans Affairs (VA) nationally integrated health care system.(14) The study was motivated largely by the high incidence of ALS in veterans.”
Evaluation of quality of life in complete locked-in syndrome patients
Rousseau, M., Pietra, S., & Nadji, M. (2012) · Annals of Physical and Rehabilitation Medicine · doi:10.1016/j.rehab.2012.07.920 · Cited by 26
Hochberg, L. R., & Cudkowicz, M. E. (2014) · Neurology · doi:10.1212/wnl.0000000000000460 · Cited by 23 · cited 1×
“Thus, BCIs that can preserve communication might affect clinical recommendations and patient decisions.(1,11,12)”
BackgroundZavalishin, I. A., & Zakharova, M. N. (2006) · Springer eBooks · doi:10.1007/3-540-29832-0_88 · Cited by 13
The Future of BCIs: Meeting the Expectations
Wolpaw, J. R., & Wolpaw, E. W. (2012) · Oxford University Press eBooks · doi:10.1093/acprof:oso/9780195388855.003.0025 · Cited by 8
Self-citationRespiratory Care in Amyotrophic Lateral Sclerosis
Heiman-Patterson, T. D., & Aboussouan, L. S. (2005) · CRC Press eBooks · doi:10.1201/b14133-37 · Cited by 2
Research works printed but not linked: 3
- Institute of Medicine. Amyotrophic Lateral Sclerosis in Veterans: Review of the Scientific Literature. Washington: National Academies Press; 2006. [Google Scholar]
- US Department of Veterans Affairs, National Center for Veterans Analysis and Statistics. Available at: va.gov/vetdata/veteranpopulation.asp (table 6L). Accessed June 2018. [Google Scholar]
- Ball LJ, Nordness AS, Fager SK, et al. Eye-gaze access to AAC technology for people with amyotrophic lateral sclerosis. J Med Speech Lang Pathol 2010;18:11–23. [Google Scholar]
Cited by
High-performance brain-to-text communication via handwriting
Willett, F. R., Avansino, D. T., Hochberg, L. R., Henderson, J. M., & Shenoy, K. V. (2021) · Nature · doi:10.1038/s41586-021-03506-2 · Cited by 1,024
“Commonly used BCIs for restoring communication are either flashing electroencephalogram (EEG) spellers 18,28–32 or intracortical point-and-click BCIs 6,7,33 .”
BackgroundMethodNeuroprosthesis for Decoding Speech in a Paralyzed Person with Anarthria
Moses, D. A., Metzger, S. L., Liu, J. R., Anumanchipalli, G. K., Makin, J. G., Sun, P. F., Chartier, J., Dougherty, M. E., Liu, P. M., Abrams, G. M., et al. (2021) · New England Journal of Medicine · doi:10.1056/nejmoa2027540 · Cited by 582
“In previously reported brain–computer interface applications, decoding models often require daily recalibration before deployment with a user,(6,35) which can increase the variability of decoder performance across days and impede longterm adoption of the interface for real-world use.(35,36) Because of the relatively h…”
BackgroundBrain-computer interfaces: Definitions and principles
(2020) · Handbook of Clinical Neurology · doi:10.1016/b978-0-444-63934-9.00002-0 · Cited by 178
Self-citationCurrent State and Future Directions in the Therapy of ALS
Tzeplaeff, L., Wilfling, S., Requardt, M. V., & Herdick, M. (2023) · Cells · doi:10.3390/cells12111523 · Cited by 148
Chaudhary, U., Vlachos, I., Zimmermann, J. B., Espinosa, A., Tonin, A., Jaramillo-Gonzalez, A., Khalili-Ardali, M., Topka, H., Lehmberg, J., Friehs, G. M., et al. (2022) · Nature Communications · doi:10.1038/s41467-022-28859-8 · Cited by 139
Metadata
- Authors
- Wolpaw, J. R., Bedlack, R. S., Reda, D. J., Ringer, R. J., Banks, P. G., Vaughan, T. M., Heckman, S. M., McCane, L. M., Carmack, C. S., Winden, S., McFarland, D. J., Sellers, E. W., Shi, H., Paine, T., Higgins, D. S., Lo, A. C., Patwa, H. S., Hill, K. J., Huang, G. D., & Ruff, R. L.
- Affiliations
- New York State Department of Health (US)
- ORCID
- Venue
- Neurology
- Published
- 2018-07-17
- Volume
- 91
- Issue
- 3
- Pages
- e258-e267
- ISSN
- 0028-3878 (ISSN-L)
- 1526-632X
- PMC
- PMC6059033
- OpenAlex
- W2810837951
- Semantic Scholar
- d5a6934fd3b00fcb9e36984e36174040ea9d0076
- Cited by
- 170
- References
- 45
- Citations by year
- 2026: 9 · 2025: 41 · 2024: 13 · 2023: 14 · 2022: 21 · 2021: 26 · 2020: 24 · 2019: 18 · 2018: 4
- FWCI
- 10.70
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Neurology (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Digital Commons - East Tennessee State University (East Tennessee State University) (submittedVersion)
- Funders
- U.S. Department of Veterans Affairs
- National Institute of Biomedical Imaging and Bioengineering (P41EB018783)
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Health Sciences › Health Professions › Occupational Therapy › Assistive Technology in Communication and Mobility
- Physical Sciences › Computer Science › Human-Computer Interaction › Gaze Tracking and Assistive Technology
- Keywords
- brain-computer interface, amyotrophic lateral sclerosis, EEG-based BCI, communication aids, caregiver education, quality of life, severely disabled patients
- MeSH terms
- Adult, Aged, Amyotrophic Lateral Sclerosis, Electroencephalography, Home Care Services, Humans, Male, Middle Aged, Self Care, Therapy, Computer-Assisted, United States, United States Department of Veterans Affairs, Brain-Computer Interfaces
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.