The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
The video head impulse test: Diagnostic accuracy in peripheral vestibulopathy
Open accessAbstract
BACKGROUND: The head impulse test (HIT) is a useful bedside test to identify peripheral vestibular deficits. However, such a deficit of the vestibulo-ocular reflex (VOR) may not be diagnosed because corrective saccades cannot always be detected by simple observation. The scleral search coil technique is the gold standard for HIT measurements, but it is not practical for routine testing or for acute patients, because they are required to wear an uncomfortable contact lens. OBJECTIVE: To develop an easy-to-use video HIT system (vHIT) as a clinical tool for identifying peripheral vestibular deficits. To validate the diagnostic accuracy of vHIT by simultaneous measures with video and search coil recordings across healthy subjects and patients with a wide range of previously identified peripheral vestibular deficits. METHODS: Horizontal HIT was recorded simultaneously with vHIT (250 Hz) and search coils (1,000 Hz) in 8 normal subjects, 6 patients with vestibular neuritis, 1 patient after unilateral intratympanic gentamicin, and 1 patient with bilateral gentamicin vestibulotoxicity. RESULTS: Simultaneous video and search coil recordings of eye movements were closely comparable (average concordance correlation coefficient r(c) = 0.930). Mean VOR gains measured with search coils and video were not significantly different in normal (p = 0.107) and patients (p = 0.073). With these groups, the sensitivity and specificity of both the reference and index test were 1.0 (95% confidence interval 0.69-1.0). vHIT measures detected both overt and covert saccades as accurately as coils. CONCLUSIONS: The video head impulse test is equivalent to search coils in identifying peripheral vestibular deficits but easier to use in clinics, even in patients with acute vestibular neuritis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A concordance correlation coefficient to evaluate reproducibility.
Lin, L. I.-K. (1989) · Biometrics · doi:10.2307/2532051 · Cited by 8,785
Towards complete and accurate reporting of studies of diagnostic accuracy: The STARD Initiative.
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Lijmer, J. G., Moher, D., Rennie, D., de Vet, H. C. W., et al. (2003) · Annals of Internal Medicine · doi:10.7326/0003-4819-138-1-200301070-00010 · Cited by 3,219
Towards complete and accurate reporting of studies of diagnostic accuracy: the STARD initiative
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Lijmer, J. G., Moher, D., Rennie, D., & de Vet, H. C. W. (2003) · BMJ · doi:10.1136/bmj.326.7379.41 · Cited by 3,215
Towards Complete and Accurate Reporting of Studies of Diagnostic Accuracy: The STARD Initiative
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Lijmer, J. G., Moher, D., Rennie, D., & de Vet, H. C. W. (2003) · Radiology · doi:10.1148/radiol.2261021292 · Cited by 3,215
A Method of Measuring Eye Movemnent Using a Scieral Search Coil in a Magnetic Field
(1963) · IEEE Transactions on Bio-medical Electronics · doi:10.1109/tbmel.1963.4322822 · Cited by 1,838
A method of measuring eye movements using a scleral search coil in a magnetic field
Robinson, D. A. (1963) · Medical Entomology and Zoology · Cited by 1,709
A Clinical Sign of Canal Paresis
Halmagyi, G. M., & Curthoys, I. S. (1988) · Archives of Neurology · doi:10.1001/archneur.1988.00520310043015 · Cited by 1,284
Self-citationMaximum permissible exposures for ocular safety (ANSI 2000), with emphasis on ophthalmic devices
Delori, F. C., Webb, R. H., & Sliney, D. H. (2007) · Journal of the Optical Society of America A · doi:10.1364/josaa.24.001250 · Cited by 480
Head impulse test in unilateral vestibular loss: Vestibulo-ocular reflex and catch-up saccades
Weber, K. P., Aw, S. T., Todd, M. J., McGarvie, L. A., Curthoys, I. S., & Halmagyi, G. M. (2008) · Neurology · doi:10.1212/01.wnl.0000299117.48935.2e · Cited by 435
Self-citationNormal head impulse test differentiates acute cerebellar strokes from vestibular neuritis
Newman-Toker, D. E., Kattah, J. C., Alvernia, J. E., & Wang, D. Z. (2008) · Neurology · doi:10.1212/01.wnl.0000314685.01433.0d · Cited by 386
Impulsive Testing of Semicircular‐Canal Function Using Video‐oculography
Weber, K. P., MacDougall, H. G., Halmagyi, G. M., & Curthoys, I. S. (2009) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.2008.03730.x · Cited by 306
Self-citationBedside differentiation of vestibular neuritis from central "vestibular pseudoneuritis"
Cnyrim, C. D., Newman-Toker, D., Karch, C., Brandt, T., & Strupp, M. (2008) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.2007.123596 · Cited by 260
Aw, S. T., Haslwanter, T., Halmagyi, G. M., Curthoys, I. S., Yavor, R. A., & Todd, M. J. (1996) · Journal of Neurophysiology · doi:10.1152/jn.1996.76.6.4009 · Cited by 203
Self-citationAccuracy of the bedside head impulse test in detecting vestibular hypofunction
Jorns-Haderli, M., Straumann, D., & Palla, A. (2007) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.2006.109512 · Cited by 195
Head Impulse Testing Using Video‐oculography
Bartl, K., Lehnen, N., Kohlbecher, S., & Schneider, E. (2009) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.2009.03850.x · Cited by 171
Levels of evidence: Taking Neurology ® to the next level
Gross, R. A., & Johnston, K. C. (2009) · Neurology · doi:10.1212/01.wnl.0000342200.58823.6a · Cited by 162
Lost in a jungle of evidence: We need a compass
Pincus, M. M. (2009) · Neurology · doi:10.1212/wnl.0b013e3181b26e15 · Cited by 149
Korczyn, A. D. (2009) · Neurology · doi:10.1212/wnl.0b013e3181b26b8b · Cited by 120
Analysis of Data on the Accuracy of Diagnostic Tests
Habbema, J. D. F., Eijkemans, M. J. C., Krijnen, P., & Knottnerus, J. A. (2008) · Wiley eBooks · doi:10.1002/9781444300574.ch7 · Cited by 50
Vertigo, its multisensory syndromes
Bruyn, G. W. (1991) · Journal of the Neurological Sciences · doi:10.1016/0022-510x(91)90177-9 · Cited by 29
Cited by
Strupp, M., Kim, J.-S., Murofushi, T., Straumann, D., Jen, J. C., Rosengren, S. M., Della Santina, C. C., & Kingma, H. (2017) · Journal of Vestibular Research · doi:10.3233/ves-170619 · Cited by 592
Tarnutzer, A. A., Berkowitz, A. L., Robinson, K. A., Hsieh, Y.-H., & Newman-Toker, D. E. (2011) · Canadian Medical Association Journal · doi:10.1503/cmaj.100174 · Cited by 462
HINTS Outperforms ABCD 2 to Screen for Stroke in Acute Continuous Vertigo and Dizziness
Newman‐Toker, D. E., Kerber, K. A., Hsieh, Y., Pula, J. H., Omron, R., Saber Tehrani, A. S., Mantokoudis, G., Hanley, D. F., Zee, D. S., & Kattah, J. C. (2013) · Academic Emergency Medicine · doi:10.1111/acem.12223 · Cited by 385
Vestibular animal models: contributions to understanding physiology and disease
Straka, H., Zwergal, A., & Cullen, K. E. (2016) · Journal of Neurology · doi:10.1007/s00415-015-7909-y · Cited by 80
Metadata
- Authors
- MacDougall, H. G., Weber, K. P., McGarvie, L. A., Halmagyi, G. M., & Curthoys, I. S.
- Venue
- Neurology
- Published
- 2009-10-06
- Volume
- 73
- Issue
- 14
- Pages
- 1134-1141
- ISSN
- 0028-3878 (ISSN-L)
- 1526-632X
- OpenAlex
- W1997303375
- Cited by
- 793
- References
- 20
- FWCI
- 10.10
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.