Different Conditions That Could Result in the Bispectral Index Indicating an Incorrect Hypnotic State
The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Abstract
Since its introduction in 1996, the Bispectral Index (BIS) has gained increasing popularity in daily anesthesia practice. However, numerous reports have been appearing in the literature of paradoxical BIS changes and inaccurate readings. The purpose of this review is to assess the utility of BIS monitoring through examining the various published reports of all BIS values not coinciding with a clinically judged sedative-hypnotic state, whether arising from an underlying pathophysiology of electroencephalographic (EEG) cerebral function or because of shortcomings in the performance and design of the BIS monitor. High electromyographic activity and electric device interference could create subtle artifact signal pollution without their necessarily being displayed as artifacts. This would be misinterpreted by the BIS algorithm as EEG activity and assigned a spuriously increased BIS value. Numerous clinical conditions that have a direct effect on EEG cerebral function could also directly influence the BIS value.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Primer for EEG Signal Processing in Anesthesia
Rampil, I. J. (1998) · Anesthesiology · doi:10.1097/00000542-199810000-00023 · Cited by 1,503
Myles, P., Leslie, K., McNeil, J., Forbes, A., & Chan, M. (2004) · The Lancet · doi:10.1016/s0140-6736(04)16300-9 · Cited by 1,301
Pharmacokinetics, Pharmacodynamics, and Rational Opioid Selection
Shafer, S. L., & Varvel, J. R. (1991) · Anesthesiology · doi:10.1097/00000542-199101000-00010 · Cited by 601
Reduction in the incidence of awareness using BIS monitoring
Ekman, A., Lindholm, M., Lennmarken, C., & Sandin, R. (2004) · Acta Anaesthesiologica Scandinavica · doi:10.1111/j.1399-6576.2004.00260.x · Cited by 394
Guignard, B., Menigaux, C., Dupont, X., Fletcher, D., & Chauvin, M. (2000) · Anesthesia & Analgesia · doi:10.1097/00000539-200001000-00034 · Cited by 360
Vivien, B., Di Maria, S., Ouattara, A., Langeron, O., Coriat, P., & Riou, B. (2003) · Anesthesiology · doi:10.1097/00000542-200307000-00006 · Cited by 292
Gugino, L. D., Chabot, R. J., Prichep, L. S., John, E. R., Formanek, V., & Aglio, L. S. (2001) · British Journal of Anaesthesia · doi:10.1093/bja/87.3.421 · Cited by 272
The Bispectral Index Declines During Neuromuscular Block in Fully Awake Persons
Messner, M., Beese, U., Romstöck, J., Dinkel, M., & Tschaikowsky, A. K. (2003) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000072741.78244.c0 · Cited by 261
Barr, G., Jakobsson, J. G., Owall, A., & Anderson, R. E. (1999) · British Journal of Anaesthesia · doi:10.1093/bja/82.6.827 · Cited by 222
Bispectral EEG Index during Nitrous Oxide Administration
Rampil, I. J., Kim, J.-S., Lenhardt, R., Negishi, C., & Sessler, D. I. (1998) · Anesthesiology · doi:10.1097/00000542-199809000-00017 · Cited by 221
Cited by
Sieber, F. E., Zakriya, K. J., Gottschalk, A., Blute, M.-R., Lee, H. B., Rosenberg, P. B., & Mears, S. C. (2010) · Mayo Clinic Proceedings · doi:10.4065/mcp.2009.0469 · Cited by 417
Kertai, M. D., Pal, N., Palanca, B. J. A., Lin, N., Searleman, S. A., Zhang, L., Burnside, B. A., Finkel, K. J., & Avidan, M. S. (2010) · Anesthesiology · doi:10.1097/aln.0b013e3181d5e0a3 · Cited by 196
“However, this observation was not replicated in another study.(15) Consistent with the hypothesis that mortality risk was not causally related to volatile anesthetic dosing or depth, we found, similar to studies in noncardiac surgery patients,(16,17) that the BIS was relatively invariant to alterations in anesthetic d…”
ResultEtomidate and its Analogs: A Review of Pharmacokinetics and Pharmacodynamics
Valk, B. I., & Struys, M. M. R. F. (2021) · Clinical Pharmacokinetics · doi:10.1007/s40262-021-01038-6 · Cited by 175
Bennett, C., Voss, L. J., Barnard, J. P. M., & Sleigh, J. W. (2009) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e3181a9fc38 · Cited by 164
“These are described in detail by Dahaba.6 Power-line artifact is probably the largest source of potential exogenous electrical artifact.”
BackgroundInfluentialCurrent status of EEG-based depth-of-consciousness monitoring during general anesthesia
Musialowicz, T., & Lahtinen, P. (2014) · Current Anesthesiology Reports · doi:10.1007/s40140-014-0061-x · Cited by 33
“During BIS monitoring for the assessment of hypnosis, various conditions, such as hypothermia, hypovolemia, and neurological disorders, could cause changes in the EEG signal such that it would indicate an incorrect hypnotic state [63].”
Background
Metadata
- Authors
- Dahaba, A. A.
- Venue
- Anesthesia & Analgesia
- Published
- 2005-09
- Volume
- 101
- Issue
- 3
- Pages
- 765-773
- ISSN
- 0003-2999 (ISSN-L)
- OpenAlex
- W2062487003
- Cited by
- 379
- References
- 35
- FWCI
- 22.06
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.