Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 213

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Malignant Hyperthermia Deaths Related to Inadequate Temperature Monitoring, 2007–2012: A Report from The North American Malignant Hyperthermia Registry of the Malignant Hyperthermia Association of the United States

Larach, Marilyn Green, Brandom, Barbara W., Allen, Gregory C., Gronert, Gerald A., Lehman, Erik B. · 2014 · Anesthesia & Analgesia

Abstract

BACKGROUND: AMRA (adverse metabolic or muscular reaction to anesthesia) reports submitted to The North American Malignant Hyperthermia Registry of the Malignant Hyperthermia Association of the United States from 1987 to 2006 revealed a 2.7% cardiac arrest and a 1.4% death rate for 291 malignant hyperthermia (MH) events. We analyzed 6 years of recent data to update MH cardiac arrest and death rates, summarized characteristics associated with cardiac arrest and death, and documented differences between early and recent cohorts of patients in the MH Registry. We also tested whether the available data supported the hypothesis that risk of dying from an episode of MH is increased in patients with inadequate temperature monitoring. METHODS: We included U.S. or Canadian reports of adverse events after administration of at least 1 anesthetic drug, received between January 1, 2007, and December 31, 2012, with an MH clinical grading scale rank of "very likely MH" or "almost certain MH." We excluded reports that, after review, were judged to be due to pathologic conditions other than MH. We analyzed patient demographics, family and patient anesthetic history, anesthetic management including temperature monitoring, initial dantrolene dose, use of cardiopulmonary resuscitation, MH complications, survival, and reported molecular genetic DNA analysis of RYR1 and CACNA1S. A one-sided Cochran-Armitage test for proportions evaluated associations between mode of monitoring and mortality. We used Miettinen and Nurminen's method for assessing the relative risk of dying according to monitoring method. We used the P value of the slope to evaluate the relationship between duration of anesthetic exposure before dantrolene administration and peak temperature. We calculated the relative risk of death in this cohort compared with our previous cohort by using the Miettinen and Nurminen method adjusted for 4 comparisons. RESULTS: Of 189 AMRA reports, 84 met our inclusion criteria. These included 7 (8.3%) cardiac arrests, no successful resuscitations, and 8 (9.5%) deaths. Of the 8 patients who died, 7 underwent elective surgeries considered low to intermediate risk. The average age of patients who died was 31.4 ± 16.9 years. Five were healthy preoperatively. Three of the 8 patients had unrevealed MH family history. Four of 8 anesthetics were performed in freestanding facilities. In those who died, 3 MH-causative RYR1 mutations and 3 RYR1 variants likely to have been pathogenic were found in the 6 patients in whom RYR1 was examined. Compared to core temperature monitoring, the relative risk of dying with no temperature monitoring was 13.8 (lower limit 2.1). Compared to core temperature monitoring, the relative risk of dying with skin temperature monitoring was 9.7 (1.5). Temperature monitoring mode best distinguished patients who lived from those who died. End-tidal CO2 was the worst physiologic measure to distinguish patients who lived from those who died. Longer anesthetic exposures before dantrolene were associated with higher peak temperatures (P = 0.00056). Compared with the early cohort, the recent cohort had a higher percentage of MH deaths (4/291 vs 8/84; relative risk = 6.9; 95% confidence interval, 1.7-28; P = 0.0043 after adjustment for 4 comparisons). CONCLUSIONS: Despite a thorough understanding of the management of MH and the availability of a specific antidote, the risk of dying from an MH episode remains unacceptably high. To increase the chance of successful MH treatment, the American Society of Anesthesiologists and Malignant Hyperthermia Association of the U.S. monitoring standards should be altered to require core temperature monitoring for all general anesthetics lasting 30 minutes or longer.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1213/ane.0000000000000421

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 213

Metadata

Authors
Larach, M. G., Brandom, B. W., Allen, G. C., Gronert, G. A., & Lehman, E. B.
Venue
Anesthesia & Analgesia
Published
2014-12
Volume
119
Issue
6
Pages
1359-1366
ISSN
0003-2999 (ISSN-L)
OpenAlex
W2334524426
Cited by
213
References
3
FWCI
18.74
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Malignant Hyperthermia Deaths Related to Inadequate Temperature Monitoring, 2007–2012: A Report from The North American Malignant Hyperthermia Registry of the Malignant Hyperthermia Association of the United States. https://app.cochat.ai/papers/10.1213/ane.0000000000000421
The paper
Larach, M. G., Brandom, B. W., Allen, G. C., Gronert, G. A., & Lehman, E. B. (2014). Malignant Hyperthermia Deaths Related to Inadequate Temperature Monitoring, 2007–2012: A Report from The North American Malignant Hyperthermia Registry of the Malignant Hyperthermia Association of the United States. Anesthesia & Analgesia. https://doi.org/10.1213/ane.0000000000000421

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.