The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
The Importance of Increased Neck Circumference to Intubation Difficulties in Obese Patients
Abstract
In Brief BACKGROUND: Using the intubation difficulty scale (IDS), we sought to confirm that obese patients are more difficult to intubate than lean patients. We assessed classical bedside tests and included neck circumference. METHODS: We prospectively compared the incidence of difficult tracheal intubation in 70 obese [body mass index (BMI) ≥30 kg/m2] and 61 lean patients (BMI <30 kg/m2). The IDS scores, categorized as difficult intubation (IDS >5) or not (IDS ≤5), and the patient data, were compared between lean and obese patients. Preoperative measurements [BMI, neck circumference (at the level of the thyroid cartilage), width of mouth opening, sternomental distance, and thyromental distance], medical history of obstructive sleep apnea syndrome, and several scores (Mallampati, Wilson, El Ganzouri) were recorded. The view during direct laryngoscopy was graded, and the IDS was recorded. We then compared patients with IDS ≤5 and >5, concerning each item. RESULTS: The results indicate that difficult tracheal intubation is more frequent in obese than in lean patients (14.3% vs 3%; P = 0.03). In the patients with IDS > 5, thyromental distance, BMI, large neck circumference, and higher Mallampati score were the only predictors of potential intubation problems. CONCLUSION: We found that problematic intubation was associated with thyromental distance, increasing neck circumference, BMI, and a Mallampati score of ≥3. Neck circumference should be assessed preoperatively to predict difficult intubation. IMPLICATIONS: We investigated what anatomical elements were associated with difficult intubation. Using the intubation difficulty scale, thyromental distance, increasing neck circumference, body mass index, and a Mallampati score ≥ 3 were associated with a higher incidence of a difficult intubation. Neck circumference should be included when assessing patients preoperatively to predict difficult intubation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Difficult tracheal intubation in obstetrics
CORMACK, R. S., & LEHANE, J. (1984) · Anaesthesia · doi:10.1111/j.1365-2044.1984.tb08932.x · Cited by 2,471
A clinical sign to predict difficult tracheal intubation; a prospective study
Mallampati, S. R., Gatt, S. P., Gugino, L. D., Desai, S. P., Waraksa, B., Freiberger, D., & Liu, P. L. (1985) · Canadian Anaesthetists’ Society Journal · doi:10.1007/bf03011357 · Cited by 2,450
CRICOID PRESSURE TO CONTROL REGURGITATION OF STOMACH CONTENTS DURING INDUCTION OF ANÆSTHESIA
Sellick, B. A. (1961) · The Lancet · doi:10.1016/s0140-6736(61)92485-0 · Cited by 951
Shiga, T., Wajima, Z., Inoue, T., & Sakamoto, A. (2005) · Anesthesiology · doi:10.1097/00000542-200508000-00027 · Cited by 902
PREDICTING DIFFICULT INTUBATION
WILSON, M. E., SPIEGELHALTER, D., ROBERTSON, J. A., & LESSER, P. (1988) · British Journal of Anaesthesia · doi:10.1093/bja/61.2.211 · Cited by 875
Adnet, F., Borron, S. W., Racine, S. X., Clemessy, J.-L., Fournier, J.-L., Plaisance, P., & Lapandry, C. (1997) · Anesthesiology · doi:10.1097/00000542-199712000-00005 · Cited by 703
Morbid Obesity and Tracheal Intubation
Brodsky, J. B., Lemmens, H. J. M., Brock-Utne, J. G., Vierra, M., & Saidman, L. J. (2002) · Anesthesia & Analgesia · doi:10.1097/00000539-200203000-00047 · Cited by 640
Preoperative Airway Assessment: Predictive Value of a Multivariate Risk Index
El-Ganzouri, A. R., McCarthy, R. J., Tuman, K. J., Tanck, E. N., & Ivankovich, A. D. (1996) · Anesthesia & Analgesia · doi:10.1097/00000539-199606000-00017 · Cited by 553
Horner, R., Mohiaddin, R., Lowell, D., Shea, S., Burman, E., Longmore, D., & Guz, A. (1989) · European Respiratory Journal · doi:10.1183/09031936.93.02070613 · Cited by 521
CHRONIC AUTONOMIC FAILURE WITH POSTURAL HYPOTENSION*1
(1979) · The Lancet · doi:10.1016/s0140-6736(79)90415-x · Cited by 498
Anesthetic and Obstetric Outcome in Morbidly Obese Parturients
Hood, D. D., & Dewan, D. M. (1993) · Anesthesiology · doi:10.1097/00000542-199312000-00011 · Cited by 436
Relative Risk Analysis of Factors Associated with Difficult Intubation in Obstetric Anesthesia
Rocke, D. A., Murray, W. B., Rout, C. C., & Gouws, E. (1992) · Anesthesiology · doi:10.1097/00000542-199207000-00010 · Cited by 402
Ezri, T., Gewürtz, G., Sessler, D. I., Medalion, B., Szmuk, P., Hagberg, C., & Susmallian, S. (2003) · Anaesthesia · doi:10.1046/j.1365-2044.2003.03412.x · Cited by 381
Relationship between difficult tracheal intubation and obstructive sleep apnoea
Hiremath, A. S., Hillman, D. R., James, A. L., Noffsinger, W. J., Platt, P. R., & Singer, S. L. (1998) · British Journal of Anaesthesia · doi:10.1093/bja/80.5.606 · Cited by 250
Adnet, F., Baillard, C., Borron, S. W., Denantes, C., Lefebvre, L., Galinski, M., Martinez, C., Cupa, M., & Lapostolle, F. (2001) · Anesthesiology · doi:10.1097/00000542-200110000-00009 · Cited by 218
Obstructive sleep apnea in the adult obese patient: implications for airway management
Benumof, J. L. (2001) · Journal of Clinical Anesthesia · doi:10.1016/s0952-8180(01)00232-x · Cited by 188
Increased body mass indexper se is not a predictor of difficult laryngoscopy
Ezri, T., Medalion, B., Weisenberg, M., Szmuk, P., Warters, R. D., & Charuzi, I. (2003) · Canadian Journal of Anesthesia/Journal canadien d'anesthésie · doi:10.1007/bf03017853 · Cited by 173
ANAESTHESIA FOR THE MORBIDLY OBESE
FOX, G. S., Whalley, D. G., & Bevan, D. R. (1981) · British Journal of Anaesthesia · doi:10.1093/bja/53.8.811 · Cited by 83
Intubation in Morbidly Obese Patients
Siyam, M. A., & Benhamou, D. (2003) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000044041.84943.d9 · Cited by 4
Cited by
The difficult airway with recommendations for management – Part 2 – The anticipated difficult airway
for the Canadian Airway Focus Group, Law, J. A., Broemling, N., Cooper, R. M., Drolet, P., Duggan, L. V., Griesdale, D. E., Hung, O. R., Jones, P. M., Kovacs, G., et al. (2013) · Canadian Journal of Anesthesia/Journal canadien d'anesthésie · doi:10.1007/s12630-013-0020-x · Cited by 276
Roth, D., Pace, N. L., Lee, A., Hovhannisyan, K., Warenits, A.-M., Arrich, J., & Herkner, H. (2018) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd008874.pub2 · Cited by 257
Deflandre, E., Degey, S., Brichant, J.-F., Poirrier, R., & Bonhomme, V. (2016) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000001089 · Cited by 36
Metadata
- Authors
- Gonzalez, H., Minville, V., Delanoue, K., Mazerolles, M., Concina, D., & Fourcade, O.
- Venue
- Anesthesia & Analgesia
- Published
- 2008-04
- Volume
- 106
- Issue
- 4
- Pages
- 1132-1136
- ISSN
- 0003-2999 (ISSN-L)
- OpenAlex
- W2140304203
- Cited by
- 306
- References
- 19
- FWCI
- 19.76
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.