A Comparison of Transmittance and Reflectance Pulse Oximetry During Vascular Surgery
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
BACKGROUND: New reflectance pulse oximetry probes placed on the forehead may be an improvement over transmittance probes placed on a finger, toe, or earlobe in patients with compromised perfusion. We compared the reliability and accuracy of the 2 types of probes in patients undergoing vascular surgery. METHODS: Patients with peripheral vascular disease undergoing vascular surgery under general anesthesia were monitored with both a transmittance earlobe probe and a reflectance forehead probe. Spo(2) was recorded continuously from both probes, and arterial blood gas samples were analyzed when clinically indicated. The average values from both probes over each minute were compared using Bland-Altman analysis. RESULTS: Twenty patients were included yielding a total of 3993 1-min averaged data pairs. Neither probe failed to report a value for more than 1 min. A Bland-Altman plot showed the limits of agreement between the probes of -4.0% to +2.6%. Twenty-eight arterial blood samples were analyzed for 14 patients and Sao(2) closely matched both Spo(2) probe values at the time of sampling. Compared with Sao(2), analysis demonstrated limits of agreement of -4.7% to 6.1% for ear and -3.3% to 3.4% for forehead sites. CONCLUSIONS: The new reflectance forehead Spo(2) probe tested has acceptable agreement with the older transmittance probe placed on the earlobe for pulse oximetry within typical ranges of Spo(2) in patients undergoing vascular surgery.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Meta-analysis of arterial oxygen saturation monitoring by pulse oximetry in adults
Jensen, L. A., Onyskiw, J. E., & Prasad, N. G. N. (1998) · Heart & Lung · doi:10.1016/s0147-9563(98)90086-3 · Cited by 243 · cited 1×
“of these sites, however, may be affected by hypothermia, vasoconstriction, and other conditions.(1)”
BackgroundThe desaturation response time of finger pulse oximeters during mild hypothermia*
MacLeod, D. B., Cortinez, L. I., Keifer, J. C., Cameron, D., Wright, D. R., White, W. D., Moretti, E. W., Radulescu, L. R., & Somma, J. (2005) · Anaesthesia · doi:10.1111/j.1365-2044.2004.04033.x · Cited by 98
Cited by
Non-contact video-based vital sign monitoring using ambient light and auto-regressive models
Tarassenko, L., Villarroel, M., Guazzi, A., Jorge, J., Clifton, D. A., & Pugh, C. (2014) · Physiological Measurement · doi:10.1088/0967-3334/35/5/807 · Cited by 423
Photoplethysmography signal processing and synthesis
Mejía-Mejía, E., Allen, J., Budidha, K., El-Hajj, C., Kyriacou, P. A., & Charlton, P. H. (2022) · Photoplethysmography · doi:10.1016/b978-0-12-823374-0.00015-3 · Cited by 138
“Reflection probes can be used at virtually any vascular tissue site since the LED and photodiode are mounted next to each other [19], and consequently are widely used in consumer wearables.”
BackgroundComparison of nasal and forehead oximetry accuracy and pressure injury in critically ill patients
Schallom, M., Prentice, D., Sona, C., Arroyo, C., & Mazuski, J. (2018) · Heart & Lung · doi:10.1016/j.hrtlng.2017.12.002 · Cited by 30
Comparing peripheral limb and forehead vital sign monitoring in newborn infants at birth
Swamy, S. K. N., Stockwell, S. J., Liu, C., Henry, C., Shipley, L., Ward, C., Mirahmadi, S., Correia, R., Morgan, S. P., Crowe, J. A., et al. (2026) · Pediatric Research · doi:10.1038/s41390-024-03651-0 · Cited by 7
“…these studies, focusing on patients with conditions such as hypothermia, 27 peripheral vasoconstriction, 14 low cardiac index, 28 vascular surgery, 29 during emergency transport, 30 or patients requiring vasopressor therapy, 31 concluded that the forehead sensor provided better quality (i.e.,…”
Metadata
- Authors
- Wax, D. B., Rubin, P., & Neustein, S.
- Venue
- Anesthesia & Analgesia
- Published
- 2009-12
- Volume
- 109
- Issue
- 6
- Pages
- 1847-1849
- ISSN
- 0003-2999 (ISSN-L)
- OpenAlex
- W2000399835
- Cited by
- 38
- References
- 3
- FWCI
- 1.55
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.