A STUDY OF THE ACCURACY OF CYBERKNIFE SPINAL RADIOSURGERY USING SKELETAL STRUCTURE TRACKING
The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: New technology has enabled the increasing use of radiosurgery to ablate spinal lesions. The first generation of the CyberKnife (Accuray, Inc., Sunnyvale, CA) image-guided radiosurgery system required implanted radiopaque markers (fiducials) to localize spinal targets. A recently developed and now commercially available spine tracking technology called Xsight (Accuray, Inc.) tracks skeletal structures and eliminates the need for implanted fiducials. The Xsight system localizes spinal targets by direct reference to the adjacent vertebral elements. This study sought to measure the accuracy of Xsight spine tracking and provide a qualitative assessment of overall system performance. METHODS: Total system error, which is defined as the distance between the centroids of the planned and delivered dose distributions and represents all possible treatment planning and delivery errors, was measured using a realistic, anthropomorphic head-and-neck phantom. The Xsight tracking system error component of total system error was also computed by retrospectively analyzing image data obtained from eleven patients with a total of 44 implanted fiducials who underwent CyberKnife spinal radiosurgery. RESULTS: The total system error of the Xsight targeting technology was measured to be 0.61 mm. The tracking system error component was found to be 0.49 mm. CONCLUSION: The Xsight spine tracking system is practically important because it is accurate and eliminates the use of implanted fiducials. Experience has shown this technology to be robust under a wide range of clinical circumstances.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Long-Term Outcome of Microvascular Decompression for Trigeminal Neuralgia
Barker, F. G., Jannetta, P. J., Bissonette, D. J., Larkins, M. V., & Jho, H. D. (1996) · New England Journal of Medicine · doi:10.1056/nejm199604253341701 · Cited by 1,426
The stereotaxic method and radiosurgery of the brain.
Leksell, L. G. (1951) · PubMed · Cited by 1,408
Predicting error in rigid-body point-based registration
Fitzpatrick, J. M., West, J. B., & Maurer, C. R. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.736021 · Cited by 1,010 · cited 1×
“This error measure is generally referred to as target registration error in the medical image registration literature, in which the word “target” denotes that the point represents an anatomic location of surgical or radiosurgical interest (9, 26, 37).”
BackgroundSelf-citationComparison and Evaluation of Retrospective Intermodality Brain Image Registration Techniques
West, J., Fitzpatrick, J. M., Wang, M. Y., Dawant, B. M., Maurer, C. R., Kessler, R. M., Maciunas, R. J., Barillot, C., Lemoine, D., Collignon, A., et al. (1997) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199707000-00007 · Cited by 884
Self-citationA comparison of similarity measures for use in 2-D-3-D medical image registration
Penney, G. P., Weese, J., Little, J. A., Desmedt, P., Hill, D. L. G., & hawkes, D. J. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.730403 · Cited by 782
Microvascular decompression of cranial nerves: lessons learned after 4400 operations
McLaughlin, M. R., Jannetta, P. J., Clyde, B. L., Subach, B. R., Comey, C. H., & Resnick, D. K. (1999) · Journal of Neurosurgery · doi:10.3171/jns.1999.90.1.0001 · Cited by 728
Registration of head volume images using implantable fiducial markers
Maurer, C. R., Fitzpatrick, J. M., Wang, M. Y., Galloway, R. L., Maciunas, R. J., & Allen, G. S. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.611354 · Cited by 561
Self-citationImage-guided Robotic Radiosurgery
Adler, J. R., Murphy, M. J., Chang, S. D., & Hancock, S. L. (1999) · Neurosurgery · doi:10.1097/00006123-199906000-00079 · Cited by 412 · cited 2×
“The CyberKnife radiosurgery system has been described previously in detail (1, 6).”
MethodSelf-citationImage-guided Hypo-fractionated Stereotactic Radiosurgery to Spinal Lesions
Ryu, S. I., Chang, S. D., Kim, D. H., Murphy, M. J., Le, Q.-T., Martin, D. P., & Adler, J. R. (2001) · Neurosurgery · doi:10.1097/00006123-200110000-00011 · Cited by 344 · cited 1×
“As a result, surgical implantation is both modestly painful and harbors the potential for complications (33).”
BackgroundSelf-citationAn Analysis of the Accuracy of the CyberKnife: A Robotic Frameless Stereotactic Radiosurgical System
(2003) · Neurosurgery · doi:10.1227/0006123-200301000-00018 · Cited by 299
Comparison and evaluation of retrospective intermodality image registration techniques:
West, J. B., Fitzpatrick, J. M., Wang, M. Y., Dawant, B. M., Maurer, Jr., Kessler, R. M., Maciunas, R. J., Barillot, C., Lemoine, D., Collignon, A. M. F., et al. (1996) · SPIE Proceedings · doi:10.1117/12.237936 · Cited by 269 · cited 4×
“The lesions ablated with radiosurgery using Xsight ranged throughout the spinal axis including the cervical (24 lesions), cervical-thoracic (3), thoracic (37), thoracic-lumbar (2), lumbar (23), lumbarsacral (2), and sacral (3) spine.”
BackgroundMethodInfluentialLemieux, L., Jagoe, R., Fish, D. R., Kitchen, N. D., & Thomas, D. G. T. (1994) · Medical Physics · doi:10.1118/1.597276 · Cited by 222 · cited 1×
“Most published intensity-based 2D-3D image registration methods iteratively vary the pose of the CT scan, generating DRRs for each pose (24, 29, 30, 32, 35).”
Neurovascular compression in trigeminal neuralgia: a clinical and anatomical study
Hamlyn, P. J., & King, T. T. (1992) · Journal of Neurosurgery · doi:10.3171/jns.1992.76.6.0948 · Cited by 201
CyberKnife Radiosurgery for Benign Intradural Extramedullary Spinal Tumors
Dodd, R. L., Ryu, M.-R., Kamnerdsupaphon, P., Gibbs, I. C., Chang, S. D., & Adler, J. R. (2006) · Neurosurgery · doi:10.1227/01.neu.0000204128.84742.8f · Cited by 174
Self-citationVoxel-based 2-D/3-D registration of fluoroscopy images and CT scans for image-guided surgery
Weese, J., Penney, G. P., Desmedt, P., Buzug, T. M., Hill, D. L. G., & Hawkes, D. J. (1997) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/4233.681173 · Cited by 164 · cited 2×
“The quantitative comparison between blocks is computed using a similarity measure called pattern intensity, which is effective for the registration of skeletal structures in x-ray projection images (30, 35).”
MethodRussakoff, D. B., Rohlfing, T., Mori, K., Rueckert, D., Ho, A., Adler, J. R., & Maurer, C. R. (2005) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2005.856749 · Cited by 142 · cited 1×
“Most published intensity-based 2D-3D image registration methods iteratively vary the pose of the CT scan, generating DRRs for each pose (24, 29, 30, 32, 35).”
Self-citationPrognostic Factors in Microvascular Decompression for Trigeminal Neuralgia
Szapiro, J., Sindou, M., & Szapiro, J. (1985) · Neurosurgery · doi:10.1227/00006123-198512000-00009 · Cited by 122
Neurosurgery in Italy: origins to modernity.
Broggi, G., Ferroli, P., Franzini, A., Nazzi, V., Farina, L., Mantia, L. L., & Milanese, C. (2004) · PubMed · Cited by 114
Penney, G. P., Batchelor, P. G., Hill, D. L. G., Hawkes, D. J., & Weese, J. (2001) · Medical Physics · doi:10.1118/1.1373400 · Cited by 112
Kobata, H., Kondo, A., Iwasaki, K., & Nishioka, T. (1998) · Neurosurgery · doi:10.1097/00006123-199812000-00052 · Cited by 102
Richards, P., Shawdon, H. H., & Illingworth, R. D. (1983) · Journal of Neurology Neurosurgery & Psychiatry · doi:10.1136/jnnp.46.12.1098 · Cited by 49
Radiosurgery and radiotherapy for sacral tumors
Gibbs, I. C., & Chang, S. D. (2003) · Neurosurgical FOCUS · doi:10.3171/foc.2003.15.2.8 · Cited by 40
Self-citationCerebellopontine Angle Osteoma Causing Trigeminal Neuralgia
Ruelle, A., Datti, R., & Andrioli, G. C. (1994) · Neurosurgery · doi:10.1227/00006123-199412000-00018 · Cited by 30
Enhancing skeletal features in digitally reconstructed radiographs
Fu, D., & Kuduvalli, G. (2006) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.652796 · Cited by 19 · cited 2×
“The resulting DRR is enhanced using postprocessing filters, including Gamma correction and top-hat filtering (10).”
BackgroundMethodSelf-citation
Cited by
A Review of 3d/2d Registration Methods for Image-Guided Interventions
Markelj, P., Tomaževič, D., Likar, B., & Pernuš, F. (2012) · Medical Image Analysis · doi:10.1016/j.media.2010.03.005 · Cited by 746
“…et al. (2003, 2009), Penney et al. (1998), Lemieux et al. (1994), Gong et al. (2006), Gottesfeld Brown and Boult (1996), Hipwell et al. (2003), Ho et al. (2007), Imamura et al. (2002), Jans et al. (2006), Jaramaz and Eckman (2006), Jonic et al. (2003), Khamene et al. (2006), Kim et al.…”
BackgroundMethodInfluentialGendrin, C., Markelj, P., Pawiro, S. A., Spoerk, J., Bloch, C., Weber, C., Figl, M., Bergmann, H., Birkfellner, W., Likar, B., et al. (2011) · Medical Physics · doi:10.1118/1.3553403 · Cited by 38
Metadata
- Authors
- Ho, A. K., Fu, D., Cotrutz, C., Hancock, S. L., Chang, S. D., Gibbs, I. C., Maurer, C. R., & Adler, J. R.
- Venue
- Operative Neurosurgery
- Published
- 2007-02
- Volume
- 60
- Issue
- 2
- Pages
- 147-156
- ISSN
- 2332-4252 (ISSN-L)
- OpenAlex
- W2050304790
- Cited by
- 163
- References
- 24
- FWCI
- 16.66
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.