Stereoelectroencephalography: Surgical Methodology, Safety, and Stereotactic Application Accuracy in 500 Procedures
The DOI matches its Crossref record; 46 of the 46 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Stereoelectroencephalography (SEEG) methodology, originally developed by Talairach and Bancaud, is progressively gaining popularity for the presurgical invasive evaluation of drug-resistant epilepsies. OBJECTIVE: To describe recent SEEG methodological implementations carried out in our center, to evaluate safety, and to analyze in vivo application accuracy in a consecutive series of 500 procedures with a total of 6496 implanted electrodes. METHODS: Four hundred nineteen procedures were performed with the traditional 2-step surgical workflow, which was modified for the subsequent 81 procedures. The new workflow entailed acquisition of brain 3-dimensional angiography and magnetic resonance imaging in frameless and markerless conditions, advanced multimodal planning, and robot-assisted implantation. Quantitative analysis for in vivo entry point and target point localization error was performed on a sub--data set of 118 procedures (1567 electrodes). RESULTS: The methodology allowed successful implantation in all cases. Major complication rate was 12 of 500 (2.4%), including 1 death for indirect morbidity. Median entry point localization error was 1.43 mm (interquartile range, 0.91-2.21 mm) with the traditional workflow and 0.78 mm (interquartile range, 0.49-1.08 mm) with the new one (P < 2.2 × 10). Median target point localization errors were 2.69 mm (interquartile range, 1.89-3.67 mm) and 1.77 mm (interquartile range, 1.25-2.51 mm; P < 2.2 × 10), respectively. CONCLUSION: SEEG is a safe and accurate procedure for the invasive assessment of the epileptogenic zone. Traditional Talairach methodology, implemented by multimodal planning and robot-assisted surgery, allows direct electrical recording from superficial and deep-seated brain structures, providing essential information in the most complex cases of drug-resistant epilepsy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
von Elm, E., Altman, D. G., Egger, M., Pocock, S. J., Gøtzsche, P. C., Vandenbroucke, J. P., & Initiative, F. T. S. (2007) · PLoS Medicine · doi:10.1371/journal.pmed.0040296 · Cited by 23,020
Advances in functional and structural MR image analysis and implementation as FSL
Smith, S. M., Jenkinson, M., Woolrich, M. W., Beckmann, C. F., Behrens, T. E. J., Johansen-Berg, H., Bannister, P. R., De Luca, M., Drobnjak, I., Flitney, D. E., et al. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.07.051 · Cited by 13,630 · cited 1×
“Holder-skin distance mm Continuous 82 (78-86) 0.”
Cortical Surface-Based Analysis
Dale, A. M., Fischl, B., & Sereno, M. I. (1999) · NeuroImage · doi:10.1006/nimg.1998.0395 · Cited by 10,910
Vandenbroucke, J. P., von Elm, E., Altman, D. G., Gøtzsche, P. C., Mulrow, C. D., Pocock, S. J., Poole, C., Schlesselman, J. J., Egger, M., & Initiative, F. T. S. (2007) · PLoS Medicine · doi:10.1371/journal.pmed.0040297 · Cited by 8,613 · cited 1×
“The present paper was edited according to the Strengthening the Reporting of Observational Studies in Epidemiology (STROBE) guidelines.(92,93)”
MethodVandenbroucke, J. P., Elm, E. V., Altman, D. G., Gøtzsche, P. C., Mulrow, C. D., Pocock, S. J., Poole, C., Schlesselman, J. J., Egger, M., & initiative, F. T. S. (2007) · Annals of Internal Medicine · doi:10.7326/0003-4819-147-8-200710160-00010-w1 · Cited by 3,543
A Randomized, Controlled Trial of Surgery for Temporal-Lobe Epilepsy
Wiebe, S., Blume, W. T., Girvin, J. P., & Eliasziw, M. (2001) · New England Journal of Medicine · doi:10.1056/nejm200108023450501 · Cited by 3,525
Bayesian analysis of neuroimaging data in FSL
Woolrich, M. W., Jbabdi, S., Patenaude, B., Chappell, M., Makni, S., Behrens, T., Beckmann, C., Jenkinson, M., & Smith, S. M. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2008.10.055 · Cited by 2,385
OsiriX: An Open-Source Software for Navigating in Multidimensional DICOM Images
Rosset, A., Spadola, L., & Ratib, O. (2004) · Journal of Digital Imaging · doi:10.1007/s10278-004-1014-6 · Cited by 1,767
Comparison and Evaluation of Retrospective Intermodality Brain Image Registration Techniques
West, J., Fitzpatrick, J. M., Wang, M. Y., Dawant, B. M., Maurer, C. R., Kessler, R. M., Maciunas, R. J., Barillot, C., Lemoine, D., Collignon, A., et al. (1997) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199707000-00007 · Cited by 884
Starr, P. A., Christine, C. W., Theodosopoulos, P. V., Lindsey, N., Byrd, D., Mosley, A., & Marks, W. J. (2002) · Journal of Neurosurgery · doi:10.3171/jns.2002.97.2.0370 · Cited by 415
Cited by
Moshé, S. L., Perucca, E., Ryvlin, P., & Tomson, T. (2015) · The Lancet · doi:10.1016/s0140-6736(14)60456-6 · Cited by 905
Epilepsy surgery in children and adults
Ryvlin, P., Cross, J. H., & Rheims, S. (2014) · The Lancet Neurology · doi:10.1016/s1474-4422(14)70156-5 · Cited by 501
Mullin, J. P., Shriver, M., Alomar, S., Najm, I., Bulacio, J., Chauvel, P., & Gonzalez‐Martinez, J. (2016) · Epilepsia · doi:10.1111/epi.13298 · Cited by 434
Technique, Results, and Complications Related to Robot-Assisted Stereoelectroencephalography
González-Martínez, J., Bulacio, J., Thompson, S., Gale, J., Smithason, S., Najm, I., & Bingaman, W. (2016) · Neurosurgery · doi:10.1227/neu.0000000000001034 · Cited by 315
Diagnostic utility of invasive EEG for epilepsy surgery: Indications, modalities, and techniques
Jayakar, P., Gotman, J., Harvey, A. S., Palmini, A., Tassi, L., Schomer, D., Dubeau, F., Bartolomei, F., Yu, A., Kršek, P., et al. (2016) · Epilepsia · doi:10.1111/epi.13515 · Cited by 281
Motor and emotional behaviours elicited by electrical stimulation of the human cingulate cortex
Caruana, F., Gerbella, M., Avanzini, P., Gozzo, F., Pelliccia, V., Mai, R., Abdollahi, R. O., Cardinale, F., Sartori, I., Lo Russo, G., et al. (2018) · Brain · doi:10.1093/brain/awy219 · Cited by 266
Self-citationGetting the best outcomes from epilepsy surgery
Vakharia, V. N., Duncan, J. S., Witt, J., Elger, C. E., Staba, R., & Engel, J. (2018) · Annals of Neurology · doi:10.1002/ana.25205 · Cited by 238
“Cardinale et al suggested a 3mm safety margin from cerebral vasculature.(53) Computer-assisted planning algorithms increase safety and reduce the time taken (see Fig 2).”
BackgroundMethodStereoelectroencephalography: retrospective analysis of 742 procedures in a single centre
Cardinale, F., Rizzi, M., Vignati, E., Cossu, M., Castana, L., d’Orio, P., Revay, M., Costanza, M. D., Tassi, L., Mai, R., et al. (2019) · Brain · doi:10.1093/brain/awz196 · Cited by 208
Self-citationTandon, N., Tong, B. A., Friedman, E. R., Johnson, J. A., Von Allmen, G., Thomas, M. S., Hope, O. A., Kalamangalam, G. P., Slater, J. D., & Thompson, S. A. (2019) · JAMA Neurology · doi:10.1001/jamaneurol.2019.0098 · Cited by 191
Robot-assisted procedures in pediatric neurosurgery
De Benedictis, A., Trezza, A., Carai, A., Genovese, E., Procaccini, E., Messina, R., Randi, F., Cossu, S., Esposito, G., Palma, P., et al. (2017) · Neurosurgical Focus · doi:10.3171/2017.2.focus16579 · Cited by 178
How to record high‐frequency oscillations in epilepsy: A practical guideline
Zijlmans, M., Worrell, G. A., Dümpelmann, M., Stieglitz, T., Barborica, A., Heers, M., Ikeda, A., Usui, N., & Le Van Quyen, M. (2017) · Epilepsia · doi:10.1111/epi.13814 · Cited by 165
Angrick, M., Ottenhoff, M. C., Diener, L., Ivucic, D., Ivucic, G., Goulis, S., Saal, J., Colon, A. J., Wagner, L., Krusienski, D. J., et al. (2021) · Communications Biology · doi:10.1038/s42003-021-02578-0 · Cited by 125
Gibbs, S. A., Proserpio, P., Francione, S., Mai, R., Cardinale, F., Sartori, I., Castana, L., Plazzi, G., Tinuper, P., Cossu, M., et al. (2019) · Epilepsia · doi:10.1111/epi.14690 · Cited by 87
Self-citationActivation of the motor cortex during phasic rapid eye movement sleep
De Carli, F., Proserpio, P., Morrone, E., Sartori, I., Ferrara, M., Gibbs, S. A., De Gennaro, L., Lo Russo, G., & Nobili, L. (2016) · Annals of Neurology · doi:10.1002/ana.24556 · Cited by 81
“1 years) with drugresistant focal epilepsy who underwent S-EEG during a presurgical evaluation.(8) Informed written consent was obtained from all patients in accordance with the hospital’s ethical committee policy (Niguarda C a Granda Hospital, Milan, Italy).”
MethodMultiple time courses of somatosensory responses in human cortex
Avanzini, P., Pelliccia, V., Lo Russo, G., Orban, G. A., & Rizzolatti, G. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2017.12.037 · Cited by 49
Gibbs, S. A., Proserpio, P., Francione, S., Mai, R., Cossu, M., Tassi, L., & Nobili, L. (2018) · Epilepsia · doi:10.1111/epi.14517 · Cited by 43
Self-citationEndovascular neuromodulation: safety profile and future directions
Raza, S. A., Opie, N. L., Morokoff, A., Sharma, R. P., Mitchell, P. J., & Oxley, T. J. (2020) · Frontiers in Neurology · doi:10.3389/fneur.2020.00351 · Cited by 29
Tonic somatosensory responses and deficits of tactile awareness converge in the parietal operculum
Del Vecchio, M., Fossataro, C., Zauli, F. M., Sartori, I., Pigorini, A., d’Orio, P., Abarrategui, B., Russo, S., Mikulan, E. P., Caruana, F., et al. (2021) · Brain · doi:10.1093/brain/awab384 · Cited by 26
Functional characteristics of the human primary somatosensory cortex: An electrostimulation study
Sun, F., Zhang, G., Yu, T., Zhang, X., Wang, X., Yan, X., Qiao, L., Ma, K., & Zhang, X. (2021) · Epilepsy & Behavior · doi:10.1016/j.yebeh.2021.107920 · Cited by 4
Metadata
- Authors
- Cardinale, F., Cossu, M., Castana, L., Casaceli, G., Schiariti, M. P., Miserocchi, A., Fuschillo, D., Moscato, A., Caborni, C., Arnulfo, G., & Lo Russo, G.
- Venue
- Neurosurgery
- Published
- 2013-03
- Volume
- 72
- Issue
- 3
- Pages
- 353-366
- ISSN
- 0148-396X (ISSN-L)
- OpenAlex
- W1973039712
- Cited by
- 527
- References
- 46
- FWCI
- 14.35
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.