Stereoelectroencephalography: Surgical Methodology, Safety, and Stereotactic Application Accuracy in 500 Procedures
Abstract
BACKGROUND: Stereoelectroencephalography (SEEG) methodology, originally developed by Talairach and Bancaud, is progressively gaining popularity for the presurgical invasive evaluation of drug-resistant epilepsies. OBJECTIVE: To describe recent SEEG methodological implementations carried out in our center, to evaluate safety, and to analyze in vivo application accuracy in a consecutive series of 500 procedures with a total of 6496 implanted electrodes. METHODS: Four hundred nineteen procedures were performed with the traditional 2-step surgical workflow, which was modified for the subsequent 81 procedures. The new workflow entailed acquisition of brain 3-dimensional angiography and magnetic resonance imaging in frameless and markerless conditions, advanced multimodal planning, and robot-assisted implantation. Quantitative analysis for in vivo entry point and target point localization error was performed on a sub--data set of 118 procedures (1567 electrodes). RESULTS: The methodology allowed successful implantation in all cases. Major complication rate was 12 of 500 (2.4%), including 1 death for indirect morbidity. Median entry point localization error was 1.43 mm (interquartile range, 0.91-2.21 mm) with the traditional workflow and 0.78 mm (interquartile range, 0.49-1.08 mm) with the new one (P < 2.2 × 10). Median target point localization errors were 2.69 mm (interquartile range, 1.89-3.67 mm) and 1.77 mm (interquartile range, 1.25-2.51 mm; P < 2.2 × 10), respectively. CONCLUSION: SEEG is a safe and accurate procedure for the invasive assessment of the epileptogenic zone. Traditional Talairach methodology, implemented by multimodal planning and robot-assisted surgery, allows direct electrical recording from superficial and deep-seated brain structures, providing essential information in the most complex cases of drug-resistant epilepsy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
von Elm, E., Altman, D. G., Egger, M., Pocock, S. J., Gøtzsche, P. C., Vandenbroucke, J. P., & Initiative, F. T. S. (2007) · PLoS Medicine · doi:10.1371/journal.pmed.0040296 · Cited by 23,020
Advances in functional and structural MR image analysis and implementation as FSL
Smith, S. M., Jenkinson, M., Woolrich, M. W., Beckmann, C. F., Behrens, T. E. J., Johansen-Berg, H., Bannister, P. R., De Luca, M., Drobnjak, I., Flitney, D. E., et al. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.07.051 · Cited by 13,630 · cited 1×
“Holder-skin distance mm Continuous 82 (78-86) 0.”
Cortical Surface-Based Analysis
Dale, A. M., Fischl, B., & Sereno, M. I. (1999) · NeuroImage · doi:10.1006/nimg.1998.0395 · Cited by 10,910
Vandenbroucke, J. P., von Elm, E., Altman, D. G., Gøtzsche, P. C., Mulrow, C. D., Pocock, S. J., Poole, C., Schlesselman, J. J., Egger, M., & Initiative, F. T. S. (2007) · PLoS Medicine · doi:10.1371/journal.pmed.0040297 · Cited by 8,613 · cited 1×
“The present paper was edited according to the Strengthening the Reporting of Observational Studies in Epidemiology (STROBE) guidelines.(92,93)”
MethodVandenbroucke, J. P., Elm, E. V., Altman, D. G., Gøtzsche, P. C., Mulrow, C. D., Pocock, S. J., Poole, C., Schlesselman, J. J., Egger, M., & initiative, F. T. S. (2007) · Annals of Internal Medicine · doi:10.7326/0003-4819-147-8-200710160-00010-w1 · Cited by 3,543
A Randomized, Controlled Trial of Surgery for Temporal-Lobe Epilepsy
Wiebe, S., Blume, W. T., Girvin, J. P., & Eliasziw, M. (2001) · New England Journal of Medicine · doi:10.1056/nejm200108023450501 · Cited by 3,525
Bayesian analysis of neuroimaging data in FSL
Woolrich, M. W., Jbabdi, S., Patenaude, B., Chappell, M., Makni, S., Behrens, T., Beckmann, C., Jenkinson, M., & Smith, S. M. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2008.10.055 · Cited by 2,385
OsiriX: An Open-Source Software for Navigating in Multidimensional DICOM Images
Rosset, A., Spadola, L., & Ratib, O. (2004) · Journal of Digital Imaging · doi:10.1007/s10278-004-1014-6 · Cited by 1,767
Comparison and Evaluation of Retrospective Intermodality Brain Image Registration Techniques
West, J., Fitzpatrick, J. M., Wang, M. Y., Dawant, B. M., Maurer, C. R., Kessler, R. M., Maciunas, R. J., Barillot, C., Lemoine, D., Collignon, A., et al. (1997) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199707000-00007 · Cited by 884
Starr, P. A., Christine, C. W., Theodosopoulos, P. V., Lindsey, N., Byrd, D., Mosley, A., & Marks, W. J. (2002) · Journal of Neurosurgery · doi:10.3171/jns.2002.97.2.0370 · Cited by 415
The Application Accuracy of Stereotactic Frames
Maciunas, R. J., Galloway, R. L., & Latimer, J. W. (1994) · Neurosurgery · doi:10.1227/00006123-199410000-00015 · Cited by 395
Pieper, S., Halle, M., & Kikinis, R. (2004) · International Symposium on Biomedical Imaging · Cited by 357
Cossu, M., Cardinale, F., Castana, L., Citterio, A., Francione, S., Tassi, L., Benabid, A. L., & Russo, G. L. (2005) · Neurosurgery · doi:10.1093/neurosurgery/57.4.706 · Cited by 332
Self-citationSurgical and Neurological Complications in a Series of 708 Epilepsy Surgery Procedures
Behrens, E., Schramm, J., Zentner, J., & König, R. (1997) · Neurosurgery · doi:10.1097/00006123-199707000-00004 · Cited by 294
Pieper, S., Lorensen, B., Schroeder, W., & Kikinis, R. (2006) · 3rd IEEE International Symposium on Biomedical Imaging: Macro to Nano, 2006. · doi:10.1109/isbi.2006.1625012 · Cited by 293
Complications of invasive video-EEG monitoring with subdural grid electrodes
Hamer, H. M., Morris, H. H., Mascha, E. J., Karafa, M. T., Bingaman, W. E., Bej, M. D., Burgess, R. C., Dinner, D. S., Foldvary, N. R., Hahn, J. F., et al. (2002) · Neurology · doi:10.1212/wnl.58.1.97 · Cited by 289
Stereotaxic Approach to Epilepsy
Talairach, J., & Bancaud, J. (2015) · Progress in Neurological Surgery · doi:10.1159/000394343 · Cited by 249
Neurophysiological Monitoring for Epilepsy Surgery: The Talairach SEEG Method
Guenot, M., Isnard, J., Ryvlin, P., Fischer, C., Ostrowsky, K., Mauguiere, F., & Sindou, M. (2001) · Stereotactic and Functional Neurosurgery · doi:10.1159/000064595 · Cited by 232
Frameless stereotaxy using bone fiducial markers for deep brain stimulation
Holloway, K. L., Gaede, S. E., Starr, P. A., Rosenow, J. M., Ramakrishnan, V., & Henderson, J. M. (2005) · Journal of Neurosurgery · doi:10.3171/jns.2005.103.3.0404 · Cited by 200
Complications of invasive subdural grid monitoring in children with epilepsy
Önal, Ç., Otsubo, H., Araki, T., Chitoku, S., Ochi, A., Weiss, S., Logan, W., Elliott, I., Snead, O. C., & Rutka, J. T. (2003) · Journal of Neurosurgery · doi:10.3171/jns.2003.98.5.1017 · Cited by 196
Li, Q. H., Zamorano, L., Pandya, A. D., Perez, R., Gong, J., & Diaz, F. (2002) · Computer Aided Surgery · doi:10.1002/igs.10035 · Cited by 178
Rydenhag, B., & Silander, H. C. (2001) · Neurosurgery · doi:10.1097/00006123-200107000-00007 · Cited by 177
Stereo-electroencephalography methodology: advantages and limits
Munari, C., Hoffmann, D., Fracione, S., Kahane, P., Tassi, L., Russo, G. L., & Benabid, A. L. (1994) · Acta Neurologica Scandinavica · doi:10.1111/j.1600-0404.1994.tb05188.x · Cited by 169
Use of the NeuroMate stereotactic robot in a frameless mode for functional neurosurgery
Varma, T. R. K., & Eldridge, P. R. (2006) · International Journal of Medical Robotics and Computer Assisted Surgery · doi:10.1002/rcs.88 · Cited by 165
Dorward, N. L., Alberti, O., Palmer, J. D., Kitchen, N. D., & Thomas, D. G. T. (1999) · Journal of Neurosurgery · doi:10.3171/jns.1999.90.1.0160 · Cited by 161
Van Gompel, J. J., Worrell, G. A., Bell, M. L., Patrick, T. A., Cascino, G. D., Raffel, C., Marsh, W. R., & Meyer, F. B. (2008) · Neurosurgery · doi:10.1227/01.neu.0000324996.37228.f8 · Cited by 158
Epilepsy Surgery in Children: Results and Predictors of Outcome on Seizures
Cossu, M., Russo, G. L., Francione, S., Mai, R., Nobili, L., Sartori, I., Tassi, L., Citterio, A., Colombo, N., Bramerio, M., et al. (2007) · Epilepsia · doi:10.1111/j.1528-1167.2007.01207.x · Cited by 153
Self-citationComputer-Driven Robot for Stereotactic Surgery Connected to CT Scan and Magnetic Resonance Imaging
Benabid, A., Cinquin, P., Lavalle, S., Bas, J. F. L., Jacques Demongeot, A., & Rougemont, J. (1987) · Stereotactic and Functional Neurosurgery · doi:10.1159/000100701 · Cited by 140
Wong, C., Birkett, J., Byth, K., Dexter, M. A. J., Somerville, E. R., Gill, D. S., Chaseling, R., Fearnside, M. R., & Bleasel, A. (2009) · Acta Neurochirurgica · doi:10.1007/s00701-008-0171-7 · Cited by 139
Complications and results of subdural grid electrode implantation in epilepsy surgery
Lee, W.-S., Lee, J. K., Lee, S., Kang, J.-K., & Ko, T. (2000) · Surgical Neurology · doi:10.1016/s0090-3019(00)00324-4 · Cited by 122
Shahlaie, K., Larson, P., & Starr, P. A. (2011) · Operative Neurosurgery · doi:10.1227/neu.0b013e31820781bc · Cited by 107
Use of Subdural Grids and Strip Electrodes to Identify a Seizure Focus in Children
Adelson, D., Black, P. M., Madsen, J. R., Kramer, U., Rockoff, M. A., Riviello, J. J., Helmers, S. L., Mikati, M. A., & Holmes, G. L. (2008) · Pediatric Neurosurgery · doi:10.1159/000120898 · Cited by 97
Subdural Electrode-Associated Complications: A 20-Year Experience
Fountas, K. N., & Smith, J. R. (2007) · Stereotactic and Functional Neurosurgery · doi:10.1159/000107358 · Cited by 93
Wiggins, G. C., Elisevich, K. V., & Smith, B. J. (1999) · Epilepsy Research · doi:10.1016/s0920-1211(99)00037-6 · Cited by 88
An Independent Application Accuracy Evaluation of Stereotactic Frame Systems
Maciunas, R. J., Galloway, R. L., Latimer, J., Cobb, C., Zaccharias, E., Moore, A., & Mandava, V. R. (1992) · Stereotactic and Functional Neurosurgery · doi:10.1159/000098981 · Cited by 87
Non-invasive investigations successfully select patients for temporal lobe surgery
Kilpatrick, C. J., Cook, M., Kaye, A. H., Murphy, M. A., & Matkovic, Z. (1997) · Journal of Neurology Neurosurgery & Psychiatry · doi:10.1136/jnnp.63.3.327 · Cited by 84
Cossu, M., Cardinale, F., Castana, L., Nobili, L., Sartori, I., & Russo, G. L. (2006) · Child s Nervous System · doi:10.1007/s00381-006-0127-2 · Cited by 81
Self-citationFerroli, P., Franzini, A., Marras, C. E., Maccagnano, E., D’Incerti, L., & Broggi, G. (2004) · Stereotactic and Functional Neurosurgery · doi:10.1159/000076655 · Cited by 70
Kelman, C. R., Ramakrishnan, V., Davies, A. J., & Holloway, K. L. (2010) · Stereotactic and Functional Neurosurgery · doi:10.1159/000316761 · Cited by 68
Complications of Invasive Monitoring Used in Intractable Pediatric Epilepsy
Simon, S. L., Telfeian, A. E., & Duhaime, A. (2002) · Pediatric Neurosurgery · doi:10.1159/000067555 · Cited by 68
Intraoperative Use of the Medtronic O-arm for Deep Brain Stimulation Procedures
Caire, F., Gantois, C., Torny, F., Ranoux, D., Maubon, A., & Moreau, J.-J. (2010) · Stereotactic and Functional Neurosurgery · doi:10.1159/000280823 · Cited by 51
Simon, S. L., Douglas, P. K., Baltuch, G. H., & Jaggi, J. L. (2005) · Stereotactic and Functional Neurosurgery · doi:10.1159/000083861 · Cited by 51
Bruce, D. A., & Bizzi, J. W. J. (2000) · Child s Nervous System · doi:10.1007/s003810000336 · Cited by 46
Musolino, A., Tournoux, P., Missir, O., et al. (1990) · PubMed · Cited by 43
Effect of MR Distortion on Targeting for Deep-Brain Stimulation
Balachandran, R., Welch, E. B., Dawant, B. M., & Fitzpatrick, J. M. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2043675 · Cited by 25
Implanted Subdural Electrodes: Safety Issues and Complication Avoidance
Fountas, K. N. (2011) · Neurosurgery Clinics of North America · doi:10.1016/j.nec.2011.07.009 · Cited by 18
Cited by
Moshé, S. L., Perucca, E., Ryvlin, P., & Tomson, T. (2015) · The Lancet · doi:10.1016/s0140-6736(14)60456-6 · Cited by 905
Epilepsy surgery in children and adults
Ryvlin, P., Cross, J. H., & Rheims, S. (2014) · The Lancet Neurology · doi:10.1016/s1474-4422(14)70156-5 · Cited by 501
Mullin, J. P., Shriver, M., Alomar, S., Najm, I., Bulacio, J., Chauvel, P., & Gonzalez‐Martinez, J. (2016) · Epilepsia · doi:10.1111/epi.13298 · Cited by 434
Technique, Results, and Complications Related to Robot-Assisted Stereoelectroencephalography
González-Martínez, J., Bulacio, J., Thompson, S., Gale, J., Smithason, S., Najm, I., & Bingaman, W. (2016) · Neurosurgery · doi:10.1227/neu.0000000000001034 · Cited by 315
Diagnostic utility of invasive EEG for epilepsy surgery: Indications, modalities, and techniques
Jayakar, P., Gotman, J., Harvey, A. S., Palmini, A., Tassi, L., Schomer, D., Dubeau, F., Bartolomei, F., Yu, A., Kršek, P., et al. (2016) · Epilepsia · doi:10.1111/epi.13515 · Cited by 281
Metadata
- Authors
- Cardinale, F., Cossu, M., Castana, L., Casaceli, G., Schiariti, M. P., Miserocchi, A., Fuschillo, D., Moscato, A., Caborni, C., Arnulfo, G., & Lo Russo, G.
- Venue
- Neurosurgery
- Published
- 2013-03
- Volume
- 72
- Issue
- 3
- Pages
- 353-366
- ISSN
- 0148-396X (ISSN-L)
- OpenAlex
- W1973039712
- Cited by
- 527
- References
- 46
- FWCI
- 14.35
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.