Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 812

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Claudin-2 expression induces cation-selective channels in tight junctions of epithelial cells

Amasheh, Salah, Meiri, Noga, Gitter, Alfred H., Schöneberg, Torsten, Mankertz, Joachim, Schulzke, Jörg D., Fromm, Michael·2002·Journal of Cell Science

Abstract

Tight junctions seal the paracellular pathway of epithelia but, in leaky tissues, also exhibit specific permeability. In order to characterize the contribution of claudin-2 to barrier and permeability properties of the tight junction in detail, we studied two strains of Madin-Darby canine kidney cells(MDCK-C7 and MDCK-C11) with different tight junctional permeabilities. Monolayers of C7 cells exhibited a high transepithelial resistance (>1 kΩ cm2), compared with C11 cells (<100 Ωcm2). Genuine expression of claudin-1 and claudin-2, but not of occludin or claudin-3, was reciprocal to transepithelial resistance. However,confocal microscopy revealed a marked subjunctional localization of claudin-1 in C11 cells, indicating that claudin-1 is not functionally related to the low tight junctional resistance of C11 cells. Strain MDCK-C7, which endogenously does not express junctional claudin-2,was transfected with claudin-2 cDNA. In transfected cells, but not in vector controls, the protein was detected in colocalization with junctional occludin by means of immunohistochemical analyses. Overexpression of claudin-2 in the originally tight epithelium with claudin-2 cDNA resulted in a 5.6-fold higher paracellular conductivity and relative ion permeabilities of Na+≡1, K+=1.02, NMDG+=0.79,choline+=0.71, Cl-=0.12, Br-=0.10 (vector control, 1:1.04:0.95:0.94:0.85:0.83). By contrast, fluxes of (radioactively labeled) mannitol and lactulose and (fluorescence labeled) 4 kDa dextran were not changed. Hence, with regular Ringer's, Na+ conductivity was 0.2 mS cm-2 in vector controls and 1.7 mS cm-2 in claudin-2-transfected cells, while Cl- conductivity was 0.2 mS cm-2 in both cells. Thus, presence of junctional claudin-2 causes the formation of cation-selective channels sufficient to transform a `tight'tight junction into a leaky one.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1242/jcs.00165

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 812

Metadata

Authors
Amasheh, S., Meiri, N., Gitter, A. H., Schöneberg, T., Mankertz, J., Schulzke, J. D., & Fromm, M.
Venue
Journal of Cell Science
Published
2002-12-15
Volume
115
Issue
24
Pages
4969-4976
ISSN
  • 0021-9533 (ISSN-L)
  • 1477-9137
OpenAlex
W2024005495
Cited by
812
References
2
FWCI
9.41
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Claudin-2 expression induces cation-selective channels in tight junctions of epithelial cells. https://app.cochat.ai/papers/10.1242/jcs.00165
The paper
Amasheh, S., Meiri, N., Gitter, A. H., Schöneberg, T., Mankertz, J., Schulzke, J. D., & Fromm, M. (2002). Claudin-2 expression induces cation-selective channels in tight junctions of epithelial cells. Journal of Cell Science. https://doi.org/10.1242/jcs.00165

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.