The DOI matches its Crossref record; 47 of the 47 references it cites were found in a registry or an index.
Imaging with total internal reflection fluorescence microscopy for the cell biologist
Open accessAbstract
Total internal reflection fluorescence (TIRF) microscopy can be used in a wide range of cell biological applications, and is particularly well suited to analysis of the localization and dynamics of molecules and events near the plasma membrane. The TIRF excitation field decreases exponentially with distance from the cover slip on which cells are grown. This means that fluorophores close to the cover slip (e.g. within ~100 nm) are selectively illuminated, highlighting events that occur within this region. The advantages of using TIRF include the ability to obtain high-contrast images of fluorophores near the plasma membrane, very low background from the bulk of the cell, reduced cellular photodamage and rapid exposure times. In this Commentary, we discuss the applications of TIRF to the study of cell biology, the physical basis of TIRF, experimental setup and troubleshooting.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cell-substrate contacts illuminated by total internal reflection fluorescence.
Axelrod, D. (1981) · The Journal of cell biology · doi:10.1083/jcb.89.1.141 · Cited by 832
Choi, C. K., Vicente-Manzanares, M., Zareno, J., Whitmore, L. A., Mogilner, A., & Horwitz, A. R. (2008) · Nature Cell Biology · doi:10.1038/ncb1763 · Cited by 797
A Modular Design for the Clathrin- and Actin-Mediated Endocytosis Machinery
Kaksonen, M., Toret, C. P., & Drubin, D. G. (2005) · Cell · doi:10.1016/j.cell.2005.09.024 · Cited by 726 · cited 1×
“TIRF also provided the spatial and temporal resolution to study the dynamics of actin and actin-associated proteins near the plasma membrane in several endocytosis studies (Kaksonen et al., 2005; Merrifield et al., 2002).”
BackgroundImaging actin and dynamin recruitment during invagination of single clathrin-coated pits
Merrifield, C. J., Feldman, M. E., Wan, L., & Almers, W. (2002) · Nature Cell Biology · doi:10.1038/ncb837 · Cited by 691
Luik, R. M., Wu, M. M., Buchanan, J., & Lewis, R. S. (2006) · The Journal of Cell Biology · doi:10.1083/jcb.200604015 · Cited by 644
Accuracy and precision in quantitative fluorescence microscopy
Waters, J. C. (2009) · Journal of Cell Biology · doi:10.1083/jcb.200903097 · Cited by 613
Superresolution Imaging using Single-Molecule Localization
Patterson, G., Davidson, M., Manley, S., & Lippincott-Schwartz, J. (2010) · Annual Review of Physical Chemistry · doi:10.1146/annurev.physchem.012809.103444 · Cited by 527
Spatial control of coated-pit dynamics in living cells
Gaidarov, I., Santini, F., Warren, R. A., & Keen, J. H. (1999) · Nature Cell Biology · doi:10.1038/8971 · Cited by 428
Kuhn, J. R., & Pollard, T. D. (2005) · Biophysical Journal · doi:10.1529/biophysj.104.047399 · Cited by 399
Clathrin mediates integrin endocytosis for focal adhesion disassembly in migrating cells
Ezratty, E. J., Bertaux, C., Marcantonio, E. E., & Gundersen, G. G. (2009) · Journal of Cell Biology · doi:10.1083/jcb.200904054 · Cited by 376
Cited by
Single Particle Tracking: From Theory to Biophysical Applications
Shen, H., Tauzin, L. J., Baiyasi, R., Wang, W., Moringo, N., Shuang, B., & Landes, C. F. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00815 · Cited by 536
Beckwith, K. S., Beckwith, M. S., Ullmann, S., Sætra, R. S., Kim, H., Marstad, A., Åsberg, S. E., Strand, T. A., Haug, M., Niederweis, M., et al. (2020) · Nature Communications · doi:10.1038/s41467-020-16143-6 · Cited by 282
A Genetically Encoded Biosensor Reveals Location Bias of Opioid Drug Action
Stoeber, M., Jullié, D., Lobingier, B. T., Laeremans, T., Steyaert, J., Schiller, P. W., Manglik, A., & von Zastrow, M. (2018) · Neuron · doi:10.1016/j.neuron.2018.04.021 · Cited by 286
Caetano, F. A., Beraldo, F. H., Hajj, G. N. M., Guimaraes, A. L., Jürgensen, S., Wasilewska-Sampaio, A. P., Hirata, P. H. F., Souza, I., Machado, C. F., Wong, D. Y.-L., et al. (2011) · Journal of Neurochemistry · doi:10.1111/j.1471-4159.2011.07225.x · Cited by 74
Breakage of the oligomeric CaMKII hub by the regulatory segment of the kinase
Karandur, D., Bhattacharyya, M., Xia, Z., Lee, Y. K., Muratcioglu, S., McAffee, D., McSpadden, E. D., Qiu, B., Groves, J. T., Williams, E. R., et al. (2020) · eLife · doi:10.7554/elife.57784 · Cited by 35
Metadata
- Authors
- Mattheyses, A. L., Simon, S. M., & Rappoport, J. Z.
- Venue
- Journal of Cell Science
- Publisher
- The Company of Biologists
- Published
- 2010-11-01
- Volume
- 123
- Issue
- 21
- Pages
- 3621-3628
- ISSN
- 0021-9533 (ISSN-L)
- 1477-9137
- OpenAlex
- W2027700316
- Cited by
- 385
- References
- 47
- FWCI
- 9.83
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Imaging with total internal reflection fluorescence microscopy for the cell biologist. https://app.cochat.ai/papers/10.1242/jcs.056218
- The paper
- Mattheyses, A. L., Simon, S. M., & Rappoport, J. Z. (2010). Imaging with total internal reflection fluorescence microscopy for the cell biologist. Journal of Cell Science. https://doi.org/10.1242/jcs.056218
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.