Mechanical anisotropy of the human knee articular cartilage in compression
The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
Articular cartilage exhibits anisotropic mechanical properties when subjected to tension. However, mechanical anisotropy of mature cartilage in compression is poorly known. In this study, both confined and unconfined compression tests of cylindrical cartilage discs, taken from the adult human patello-femoral groove and cut either perpendicular (normal disc) or parallel (tangential disc) to the articular surface, were utilized to determine possible anisotropy in Young's modulus, E, aggregate modulus, H a, Poisson's ratio, v and hydraulic permeability, k, of articular cartilage. The results indicated that H a was significantly higher in the direction parallel to the articular surface as compared with the direction perpendicular to the surface ( H a = 1.237 ± 0.486 MPa versus H a = 0.845 ± 0.383 MPa, p = 0.017, n = 10). The values of Poisson's ratio were similar, 0.158 ± 0.148 for normal discs compared with 0.180 ± 0.046 for tangential discs. Analysis using the linear biphasic model revealed that the decrease of permeability during the offset compression of 0–20 per cent was higher ( p = 0.015, n = 10) in normal (from 25.5 × 10− 15 to 1.8 × 10−15 m 4/N s) than in tangential (from 12.3 × 10− 15 to 1.3 × 10− 15 m 4/N s) discs. Based on the results, it is concluded that the mechanical characteristics of adult femoral groove articular cartilage are anisotropic also during compression. Anisotropy during compression may be essential for normal cartilage function. This property has to be considered when developing advanced theoretical models for cartilage biomechanics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biphasic Creep and Stress Relaxation of Articular Cartilage in Compression: Theory and Experiments
Mow, V. C., Kuei, S. C., Lai, W. M., & Armstrong, C. G. (1980) · Journal of Biomechanical Engineering · doi:10.1115/1.3138202 · Cited by 2,444
Cartilage and diarthrodial joints as paradigms for hierarchical materials and structures
Mow, V. C., Ratcliffe, A., & Robin Poole, A. (1992) · Biomaterials · doi:10.1016/0142-9612(92)90001-5 · Cited by 956
Articular cartilage and osteoarthritis
Dziak, R. (1992) · Bone and Mineral · doi:10.1016/0169-6009(92)90848-8 · Cited by 843
Depth‐dependent confined compression modulus of full‐thickness bovine articular cartilage
Schinagl, R. M., Gurskis, D., Chen, A. C., & Sah, R. L. (1997) · Journal of Orthopaedic Research · doi:10.1002/jor.1100150404 · Cited by 646
The frictional properties of animal joints
McCutchen, C. W. (1962) · Wear · doi:10.1016/0043-1648(62)90176-x · Cited by 640
Wainwright, D. (1974) · Injury · doi:10.1016/0020-1383(74)90182-x · Cited by 511
Akizuki, S., Mow, V. C., Müller, F., Pita, J. C., Howell, D. S., & Manicourt, D. H. (1986) · Journal of Orthopaedic Research · doi:10.1002/jor.1100040401 · Cited by 504
Correlations between stiffness and the chemical constituents of cartilage on the human femoral head
Kempson, G. E., Muir, H., Swanson, S. A. V., & Freeman, M. A. R. (1970) · Biochimica et Biophysica Acta (BBA) - General Subjects · doi:10.1016/0304-4165(70)90388-0 · Cited by 389
Optical and mechanical determination of poisson's ratio of adult bovine humeral articular cartilage
Jurvelin, J. S., Buschmann, M. D., & Hunziker, E. B. (1997) · Journal of Biomechanics · doi:10.1016/s0021-9290(96)00133-9 · Cited by 344
Self-citationSoltz, M. A., & Ateshian, G. A. (2000) · Journal of Biomechanical Engineering · doi:10.1115/1.1324669 · Cited by 330
A Fibril-Network-Reinforced Biphasic Model of Cartilage in Unconfined Compression
Soulhat, J., Buschmann, M. D., & Shirazi-Adl, A. (1999) · Journal of Biomechanical Engineering · doi:10.1115/1.2798330 · Cited by 250
Self-citationRecent Developments in Synovial Joint Biomechanics
Mow, V. C., & Lai, W. M. (1980) · SIAM Review · doi:10.1137/1022056 · Cited by 235
Quinn, T. M., Dierickx, P. W., & Grodzinsky, A. J. (2001) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00103-8 · Cited by 103
Khalsa, P. S., & Eisenberg, S. R. (1997) · Journal of Biomechanics · doi:10.1016/s0021-9290(97)84508-3 · Cited by 85
Cited by
Biomaterials for articular cartilage tissue engineering: Learning from biology
Armiento, A. R., Stoddart, M. J., Alini, M., & Eglin, D. (2018) · Acta Biomaterialia · doi:10.1016/j.actbio.2017.11.021 · Cited by 579
Korhonen, R. K., Laasanen, M. S., Töyräs, J., Rieppo, J., Hirvonen, J., Helminen, H. J., & Jurvelin, J. S. (2002) · Journal of Biomechanics · doi:10.1016/s0021-9290(02)00052-0 · Cited by 464
Self-citationBian, L., Guvendiren, M., Mauck, R. L., & Burdick, J. A. (2013) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1214100110 · Cited by 401
Bai, R., Yang, J., & Suo, Z. (2019) · European Journal of Mechanics - A/Solids · doi:10.1016/j.euromechsol.2018.12.001 · Cited by 346
Soltz, M. A., & Ateshian, G. A. (2000) · Journal of Biomechanical Engineering · doi:10.1115/1.1324669 · Cited by 330
Metadata
- Authors
- Jurvelin, J. S., Buschmann, M. D., & Hunziker, E. B.
- Venue
- Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
- Publisher
- SAGE Publications
- Published
- 2003-03-01
- Volume
- 217
- Issue
- 3
- Pages
- 215-219
- ISSN
- 0954-4119 (ISSN-L)
- 2041-3033
- OpenAlex
- W2075140947
- Cited by
- 194
- References
- 14
- FWCI
- 4.10
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.