CoChat

The use of acellular matrices for the tissue engineering of cardiac valves

Knight, R L, Wilcox, H E, Korossis, S A, Fisher, J, Ingham, E · 2008 · Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
Cited by 97

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Tissue-engineering approaches to cardiac valve replacement have made considerable advances over recent years and it is likely that this application will realize clinical success in the near future. Research in this area has been driven by the inadequacy of the currently available cardiac valve prostheses for younger patients who require multiple reoperations as they grow and develop. Tissue engineering has the potential to provide a valve capable of the same growth, repair, and regeneration as a natural valve and could improve outcomes for patients of all ages. Owing to the function and physical environment of the cardiac valve, the development of tissue-engineered replacements is unusual in that the biomechanical properties of the construct must dominate the biological properties in order for the valve to be functional at the time of implantation. As a result of this, conventional tissue-engineering scaffolds based on biodegradable polymers or collagen may not at present be suitable in this situation because of their initial limited strength. Research into the use of acellular xenogeneic and allogeneic matrices for tissue-engineered heart valves has consequently become extremely popular since the biomechanical properties of the valve can potentially be preserved with an optimal decellularization technique that removes the cells without damaging the matrix. A number of acellular scaffolds have already been tested clinically both unseeded and preseeded with cells and these have met with variable results. This article reviews the concepts involved and the advantages and disadvantages of the different approaches to tissue engineering a living cardiac valve.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1243/09544119jeim230

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 97

Metadata

Authors
Knight, R. L., Wilcox, H. E., Korossis, S. A., Fisher, J., & Ingham, E.
Venue
Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
Published
2008-01
Volume
222
Issue
1
Pages
129-143
ISSN
  • 0954-4119 (ISSN-L)
  • 2041-3033
OpenAlex
W2109528615
Cited by
97
References
2
FWCI
8.40
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The use of acellular matrices for the tissue engineering of cardiac valves. https://app.cochat.ai/papers/10.1243/09544119jeim230
The paper
Knight, R. L., Wilcox, H. E., Korossis, S. A., Fisher, J., & Ingham, E. (2008). The use of acellular matrices for the tissue engineering of cardiac valves. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. https://doi.org/10.1243/09544119jeim230

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.