The FLARE™ Intraoperative Near-Infrared Fluorescence Imaging System: A First-in-Human Clinical Trial in Breast Cancer Sentinel Lymph Node Mapping
Open accessThe DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Abstract
BackgroundInvisible NIR fluorescent light can provide high sensitivity, high-resolution, and real-time image-guidance during oncologic surgery, but imaging systems that are presently available do not display this invisible light in the context of surgical anatomy. The FLARE™ imaging system overcomes this major obstacle.MethodsColor video was acquired simultaneously, and in real-time, along with two independent channels of NIR fluorescence. Grayscale NIR fluorescence images were converted to visible “pseudo-colors” and overlaid onto the color video image. Yorkshire pigs weighing 35 kg (n = 5) were used for final preclinical validation of the imaging system. A six-patient pilot study was conducted in women undergoing sentinel lymph node (SLN) mapping for breast cancer. Subjects received 99mTc-sulfur colloid lymphoscintigraphy. In addition, 12.5 μg of indocyanine green (ICG) diluted in human serum albumin (HSA) was used as an NIR fluorescent lymphatic tracer.ResultsThe FLARE™ system permitted facile positioning in the operating room. NIR light did not change the look of the surgical field. Simultaneous pan-lymphatic and SLN mapping was demonstrated in swine using clinically available NIR fluorophores and the dual NIR capabilities of the system. In the pilot clinical trial, a total of nine SLNs were identified by 99mTc- lymphoscintigraphy and nine SLNs were identified by NIR fluorescence, although results differed in two patients. No adverse events were encountered.ConclusionsWe describe the successful clinical translation of a new NIR fluorescence imaging system for image-guided oncologic surgery.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Renal clearance of quantum dots
Soo Choi, H., Liu, W., Misra, P., Tanaka, E., Zimmer, J. P., Itty Ipe, B., Bawendi, M. G., & Frangioni, J. V. (2007) · Nature Biotechnology · doi:10.1038/nbt1340 · Cited by 4,476
Self-citationIn vivo near-infrared fluorescence imaging
Frangioni, J. V. (2003) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2003.08.007 · Cited by 2,653
Self-citationNear-infrared fluorescent type II quantum dots for sentinel lymph node mapping
Kim, S., Lim, Y. T., Soltesz, E. G., De Grand, A. M., Lee, J., Nakayama, A., Parker, J. A., Mihaljevic, T., Laurence, R. G., Dor, D. M., et al. (2004) · Nature Biotechnology · doi:10.1038/nbt920 · Cited by 2,087
Self-citationNew Technologies for Human Cancer Imaging
Frangioni, J. V. (2008) · Journal of Clinical Oncology · doi:10.1200/jco.2007.14.3065 · Cited by 800
Self-citationFluorescence navigation with indocyanine green for detecting sentinel lymph nodes in breast cancer
Kitai, T., Inomoto, T., Miwa, M., & Shikayama, T. (2005) · Breast Cancer · doi:10.2325/jbcs.12.211 · Cited by 677
Compact Cysteine-Coated CdSe(ZnCdS) Quantum Dots for in Vivo Applications
Liu, W., Choi, H. S., Zimmer, J. P., Tanaka, E., Frangioni, J. V., & Bawendi, M. (2007) · Journal of the American Chemical Society · doi:10.1021/ja073790m · Cited by 415
Self-citationZimmer, J. P., Kim, S.-W., Ohnishi, S., Tanaka, E., Frangioni, J. V., & Bawendi, M. G. (2006) · Journal of the American Chemical Society · doi:10.1021/ja0579816 · Cited by 406
Self-citationIn vivo near-infrared fluorescence imaging of osteoblastic activity
Zaheer, A., Lenkinski, R. E., Mahmood, A., Jones, A. G., Cantley, L. C., & Frangioni, J. V. (2001) · Nature Biotechnology · doi:10.1038/nbt1201-1148 · Cited by 374
Self-citationKusano, M., Tajima, Y., Yamazaki, K., Kato, M., Watanabe, M., & Miwa, M. (2008) · Digestive Surgery · doi:10.1159/000121905 · Cited by 315
Tanaka, E., Choi, H. S., Fujii, H., Bawendi, M. G., & Frangioni, J. V. (2006) · Annals of Surgical Oncology · doi:10.1245/s10434-006-9194-6 · Cited by 262
Self-citationIntraoperative Sentinel Lymph Node Mapping of the Lung Using Near-Infrared Fluorescent Quantum Dots
Soltesz, E. G., Kim, S., Laurence, R. G., DeGrand, A. M., Parungo, C. P., Dor, D. M., Cohn, L. H., Bawendi, M. G., Frangioni, J. V., & Mihaljevic, T. (2005) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2004.06.055 · Cited by 244
Self-citationEngineering InAsxP1-x/InP/ZnSe III−V Alloyed Core/Shell Quantum Dots for the Near-Infrared
Kim, S.-W., Zimmer, J. P., Ohnishi, S., Tracy, J. B., Frangioni, J. V., & Bawendi, M. G. (2005) · Journal of the American Chemical Society · doi:10.1021/ja0434331 · Cited by 242
Self-citationOhnishi, S., Lomnes, S. J., Laurence, R. G., Gogbashian, A., Mariani, G., & Frangioni, J. V. (2005) · Molecular Imaging · doi:10.1162/15353500200505127 · Cited by 210
Self-citationAn Operational Near-Infrared Fluorescence Imaging System Prototype for Large Animal Surgery
De Grand, A. M., & Frangioni, J. V. (2003) · Technology in Cancer Research & Treatment · doi:10.1177/153303460300200607 · Cited by 189
Self-citationMiyashiro, I., Miyoshi, N., Hiratsuka, M., Kishi, K., Yamada, T., Ohue, M., Ohigashi, H., Yano, M., Ishikawa, O., & Imaoka, S. (2008) · Annals of Surgical Oncology · doi:10.1245/s10434-008-9872-7 · Cited by 185
Detection of Breast Cancer Microcalcifications Using a Dual-modality SPECT/NIR Fluorescent Probe
Bhushan, K. R., Misra, P., Liu, F., Mathur, S., Lenkinski, R. E., & Frangioni, J. V. (2008) · Journal of the American Chemical Society · doi:10.1021/ja807099s · Cited by 131
Self-citationLymphatic Drainage of the Peritoneal Space: A Pattern Dependent on Bowel Lymphatics
Parungo, C. P., Soybel, D. I., Colson, Y. L., Kim, S., Ohnishi, S., Grand, A. M. D., Laurence, R. G., Soltesz, E. G., Chen, F. Y., Cohn, L. H., et al. (2006) · Annals of Surgical Oncology · doi:10.1245/s10434-006-9044-6 · Cited by 117
Self-citationSentinel Lymph Node Mapping of the Pleural Space
Parungo, C. P., Colson, Y. L., Kim, S., Kim, S., Cohn, L. H., Bawendi, M. G., & Frangioni, J. V. (2005) · CHEST Journal · doi:10.1378/chest.127.5.1799 · Cited by 112
Self-citationNakayama, A., Bianco, A. C., Zhang, C., Lowell, B. B., & Frangioni, J. V. (2003) · Molecular Imaging · doi:10.1162/153535003765276273 · Cited by 109
Self-citationHumblet, V., Lapidus, R. S., Williams, L. R., Tsukamoto, T., Rojas, C. J., Majer, P., Hin, B., Ohnishi, S., Grand, A. M. D., Zaheer, A., et al. (2005) · Molecular Imaging · doi:10.2310/7290.2005.05163 · Cited by 96
Self-citationSentinel Lymph Node Mapping With Type-II Quantum Dots
Frangioni, J. V., Kim, S., Ohnishi, S., Kim, S., & Bawendi, M. G. (2007) · Humana Press eBooks · doi:10.1385/1-59745-369-2:147 · Cited by 85
Self-citationFunctional Near-Infrared Imaging for Cardiac Surgery and Targeted Gene Therapy
Nakayama, A., del Monte, F., Hajjar, R. J., & Frangioni, J. V. (2002) · Molecular Imaging · doi:10.1162/153535002321093972 · Cited by 77
Self-citationFunctional Near-Infrared Fluorescence Imaging for Cardiac Surgery and Targeted Gene Therapy
Nakayama, A., del Monte, F., Hajjar, R. J., & Frangioni, J. V. (2002) · Molecular Imaging · doi:10.1162/15353500200221333 · Cited by 75
Self-citationTanaka, E., Chen, F. Y., Flaumenhaft, R. C., Graham, G. J., Laurence, R. G., & Frangioni, J. V. (2009) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2008.09.082 · Cited by 70
Self-citationOn the Benefit of Bivalency in Peptide Ligand/Pin1 Interactions
Daum, S., Lücke, C., Wildemann, D., & Schiene‐Fischer, C. (2007) · Journal of Molecular Biology · doi:10.1016/j.jmb.2007.09.019 · Cited by 61
Flaumenhaft, R. C., Tanaka, E., Graham, G. J., Grand, A. M. D., Laurence, R. G., Hoshino, K., Hajjar, R. J., & Frangioni, J. V. (2006) · Circulation · doi:10.1161/circulationaha.106.643908 · Cited by 57
Self-citationOptical Imaging of Hydroxyapatite in the Calcified Vasculature of Transgenic Animals
Zaheer, A., Murshed, M., Grand, A. M. D., Morgan, T. G., Karsenty, G., & Frangioni, J. V. (2006) · Arteriosclerosis Thrombosis and Vascular Biology · doi:10.1161/01.atv.0000210016.89991.2a · Cited by 55
Self-citation
Cited by
Near-infrared fluorophores for biomedical imaging
Hong, G., Antaris, A. L., & Dai, H. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-016-0010 · Cited by 2,985
A small-molecule dye for NIR-II imaging
Antaris, A. L., Chen, H., Cheng, K., Sun, Y., Hong, G., Qu, C., Diao, S., Deng, Z., Hu, X., Zhang, B., et al. (2016) · Nature Materials · doi:10.1038/nmat4476 · Cited by 1,778
van Dam, G. M., Themelis, G., Crane, L. M. A., Harlaar, N. J., Pleijhuis, R. G., Kelder, W., Sarantopoulos, A., de Jong, J. S., Arts, H. J. G., van der Zee, A. G. J., et al. (2011) · Nature Medicine · doi:10.1038/nm.2472 · Cited by 1,545
Image-guided cancer surgery using near-infrared fluorescence
Vahrmeijer, A. L., Hutteman, M., van der Vorst, J. R., van de Velde, C. J. H., & Frangioni, J. V. (2013) · Nature Reviews Clinical Oncology · doi:10.1038/nrclinonc.2013.123 · Cited by 1,466
Self-citationAdvanced Fluorescence Imaging Technology in the Near-Infrared-II Window for Biomedical Applications
Li, C., Chen, G., Zhang, Y., Wu, F., & Wang, Q. (2020) · Journal of the American Chemical Society · doi:10.1021/jacs.0c07022 · Cited by 1,037
Metadata
- Authors
- Troyan, S. L., Kianzad, V., Gibbs-Strauss, S. L., Gioux, S., Matsui, A., Oketokoun, R., Ngo, L., Khamene, A., Azar, F., & Frangioni, J. V.
- Venue
- Annals of Surgical Oncology
- Published
- 2009-07-07
- Volume
- 16
- Issue
- 10
- Pages
- 2943-2952
- ISSN
- 1068-9265 (ISSN-L)
- 1534-4681
- OpenAlex
- W2168544783
- Cited by
- 684
- References
- 27
- FWCI
- 32.88
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.