The FLARE™ Intraoperative Near-Infrared Fluorescence Imaging System: A First-in-Human Clinical Trial in Breast Cancer Sentinel Lymph Node Mapping
Open accessThe DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Abstract
BackgroundInvisible NIR fluorescent light can provide high sensitivity, high-resolution, and real-time image-guidance during oncologic surgery, but imaging systems that are presently available do not display this invisible light in the context of surgical anatomy. The FLARE™ imaging system overcomes this major obstacle.MethodsColor video was acquired simultaneously, and in real-time, along with two independent channels of NIR fluorescence. Grayscale NIR fluorescence images were converted to visible “pseudo-colors” and overlaid onto the color video image. Yorkshire pigs weighing 35 kg (n = 5) were used for final preclinical validation of the imaging system. A six-patient pilot study was conducted in women undergoing sentinel lymph node (SLN) mapping for breast cancer. Subjects received 99mTc-sulfur colloid lymphoscintigraphy. In addition, 12.5 μg of indocyanine green (ICG) diluted in human serum albumin (HSA) was used as an NIR fluorescent lymphatic tracer.ResultsThe FLARE™ system permitted facile positioning in the operating room. NIR light did not change the look of the surgical field. Simultaneous pan-lymphatic and SLN mapping was demonstrated in swine using clinically available NIR fluorophores and the dual NIR capabilities of the system. In the pilot clinical trial, a total of nine SLNs were identified by 99mTc- lymphoscintigraphy and nine SLNs were identified by NIR fluorescence, although results differed in two patients. No adverse events were encountered.ConclusionsWe describe the successful clinical translation of a new NIR fluorescence imaging system for image-guided oncologic surgery.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Renal clearance of quantum dots
Soo Choi, H., Liu, W., Misra, P., Tanaka, E., Zimmer, J. P., Itty Ipe, B., Bawendi, M. G., & Frangioni, J. V. (2007) · Nature Biotechnology · doi:10.1038/nbt1340 · Cited by 4,476
Self-citationIn vivo near-infrared fluorescence imaging
Frangioni, J. V. (2003) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2003.08.007 · Cited by 2,653
Self-citationNear-infrared fluorescent type II quantum dots for sentinel lymph node mapping
Kim, S., Lim, Y. T., Soltesz, E. G., De Grand, A. M., Lee, J., Nakayama, A., Parker, J. A., Mihaljevic, T., Laurence, R. G., Dor, D. M., et al. (2004) · Nature Biotechnology · doi:10.1038/nbt920 · Cited by 2,087
Self-citationNew Technologies for Human Cancer Imaging
Frangioni, J. V. (2008) · Journal of Clinical Oncology · doi:10.1200/jco.2007.14.3065 · Cited by 800
Self-citationFluorescence navigation with indocyanine green for detecting sentinel lymph nodes in breast cancer
Kitai, T., Inomoto, T., Miwa, M., & Shikayama, T. (2005) · Breast Cancer · doi:10.2325/jbcs.12.211 · Cited by 677
Compact Cysteine-Coated CdSe(ZnCdS) Quantum Dots for in Vivo Applications
Liu, W., Choi, H. S., Zimmer, J. P., Tanaka, E., Frangioni, J. V., & Bawendi, M. (2007) · Journal of the American Chemical Society · doi:10.1021/ja073790m · Cited by 415
Self-citationZimmer, J. P., Kim, S.-W., Ohnishi, S., Tanaka, E., Frangioni, J. V., & Bawendi, M. G. (2006) · Journal of the American Chemical Society · doi:10.1021/ja0579816 · Cited by 406
Self-citationIn vivo near-infrared fluorescence imaging of osteoblastic activity
Zaheer, A., Lenkinski, R. E., Mahmood, A., Jones, A. G., Cantley, L. C., & Frangioni, J. V. (2001) · Nature Biotechnology · doi:10.1038/nbt1201-1148 · Cited by 374
Self-citationKusano, M., Tajima, Y., Yamazaki, K., Kato, M., Watanabe, M., & Miwa, M. (2008) · Digestive Surgery · doi:10.1159/000121905 · Cited by 315
Tanaka, E., Choi, H. S., Fujii, H., Bawendi, M. G., & Frangioni, J. V. (2006) · Annals of Surgical Oncology · doi:10.1245/s10434-006-9194-6 · Cited by 262
Self-citation
Cited by
Near-infrared fluorophores for biomedical imaging
Hong, G., Antaris, A. L., & Dai, H. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-016-0010 · Cited by 2,985
A small-molecule dye for NIR-II imaging
Antaris, A. L., Chen, H., Cheng, K., Sun, Y., Hong, G., Qu, C., Diao, S., Deng, Z., Hu, X., Zhang, B., et al. (2016) · Nature Materials · doi:10.1038/nmat4476 · Cited by 1,778
van Dam, G. M., Themelis, G., Crane, L. M. A., Harlaar, N. J., Pleijhuis, R. G., Kelder, W., Sarantopoulos, A., de Jong, J. S., Arts, H. J. G., van der Zee, A. G. J., et al. (2011) · Nature Medicine · doi:10.1038/nm.2472 · Cited by 1,545
Image-guided cancer surgery using near-infrared fluorescence
Vahrmeijer, A. L., Hutteman, M., van der Vorst, J. R., van de Velde, C. J. H., & Frangioni, J. V. (2013) · Nature Reviews Clinical Oncology · doi:10.1038/nrclinonc.2013.123 · Cited by 1,466
Self-citationAdvanced Fluorescence Imaging Technology in the Near-Infrared-II Window for Biomedical Applications
Li, C., Chen, G., Zhang, Y., Wu, F., & Wang, Q. (2020) · Journal of the American Chemical Society · doi:10.1021/jacs.0c07022 · Cited by 1,037
Schaafsma, B. E., Mieog, J. S. D., Hutteman, M., van der Vorst, J. R., Kuppen, P. J. K., Löwik, C. W. G. M., Frangioni, J. V., van de Velde, C. J. H., & Vahrmeijer, A. L. (2011) · Journal of Surgical Oncology · doi:10.1002/jso.21943 · Cited by 816
Self-citationRapid translocation of nanoparticles from the lung airspaces to the body
Choi, H. S., Ashitate, Y., Lee, J. H., Kim, S. H., Matsui, A., Insin, N., Bawendi, M. G., Semmler-Behnke, M., Frangioni, J. V., & Tsuda, A. (2010) · Nature Biotechnology · doi:10.1038/nbt.1696 · Cited by 648
Self-citationImage-Guided Surgery Using Invisible Near-Infrared Light: Fundamentals of Clinical Translation
Gioux, S., Choi, H. S., & Frangioni, J. V. (2010) · Molecular Imaging · doi:10.2310/7290.2010.00034 · Cited by 599
Self-citationFluorescence imaging of pathophysiological microenvironments
Wang, S., Ren, W. X., Hou, J.-T., Won, M., An, J., Chen, X., Shu, J., & Kim, J. S. (2021) · Chemical Society Reviews · doi:10.1039/d1cs00083g · Cited by 568
Targeted zwitterionic near-infrared fluorophores for improved optical imaging
Choi, H. S., Gibbs, S. L., Lee, J. H., Kim, S. H., Ashitate, Y., Liu, F., Hyun, H., Park, G., Xie, Y., Bae, S., et al. (2013) · Nature Biotechnology · doi:10.1038/nbt.2468 · Cited by 560
Self-citationDonor Engineering for NIR-II Molecular Fluorophores with Enhanced Fluorescent Performance
Yang, Q., Hu, Z., Zhu, S., Ma, R., Ma, H., Ma, Z., Wan, H., Zhu, T., Jiang, Z., Liu, W., et al. (2018) · Journal of the American Chemical Society · doi:10.1021/jacs.7b10334 · Cited by 554
Beyond the margins: real-time detection of cancer using targeted fluorophores
Zhang, R. R., Schroeder, A. B., Grudzinski, J. J., Rosenthal, E. L., Warram, J. M., Pinchuk, A. N., Eliceiri, K. W., Kuo, J. S., & Weichert, J. P. (2017) · Nature Reviews Clinical Oncology · doi:10.1038/nrclinonc.2016.212 · Cited by 485
DSouza, A. V., Lin, H., Henderson, E. R., Samkoe, K. S., & Pogue, B. W. (2016) · Journal of Biomedical Optics · doi:10.1117/1.jbo.21.8.080901 · Cited by 414
Synthesis and In Vivo Fate of Zwitterionic Near‐Infrared Fluorophores
Choi, H. S., Nasr, K., Alyabyev, S., Feith, D., Lee, J. H., Kim, S. H., Ashitate, Y., Hyun, H., Patonay, G., Strekowski, L., et al. (2011) · Angewandte Chemie International Edition · doi:10.1002/anie.201102459 · Cited by 378
Self-citationChi, C., Du, Y., Ye, J., Kou, D., Qiu, J., Wang, J., Tian, J., & Chen, X. (2014) · Theranostics · doi:10.7150/thno.9899 · Cited by 358
Nanoparticles for Biomedical Imaging: Fundamentals of Clinical Translation
Choi, H. S., & Frangioni, J. V. (2010) · Molecular Imaging · doi:10.2310/7290.2010.00031 · Cited by 351
Self-citationZhu, S., Hu, Z., Tian, R., Yung, B. C., Yang, Q., Zhao, S., Kiesewetter, D. O., Niu, G., Sun, H., Antaris, A. L., et al. (2018) · Advanced Materials · doi:10.1002/adma.201802546 · Cited by 349
Upconverting and NIR emitting rare earth based nanostructures for NIR-bioimaging
Hemmer, E., Venkatachalam, N., Hyodo, H., Hattori, A., Ebina, Y., Kishimoto, H., & Soga, K. (2013) · Nanoscale · doi:10.1039/c3nr02286b · Cited by 343
Near-Infrared Fluorescence Imaging in Humans with Indocyanine Green: A Review and Update
Marshall, M. V., Rasmussen, J. C., Tan, I.-C., Aldrich, M. B., Adams, K. E., Wang, X., Fife, C. E., Maus, E. A., Smith, L. A., & Sevick-Muraca, E. M. (2010) · The Open Surgical Oncology Journal · doi:10.2174/1876504101002010012 · Cited by 341
Molecular imaging for cancer diagnosis and surgery
Hussain, T., & Nguyen, Q. T. (2014) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2013.09.007 · Cited by 337
Gong, Z., & Dai, Z. (2021) · Advanced Science · doi:10.1002/advs.202002178 · Cited by 320
Near-Infrared-II (NIR-II) Bioimaging via Off-Peak NIR-I Fluorescence Emission
Zhu, S., Yung, B. C., Chandra, S., Niu, G., Antaris, A. L., & Chen, X. (2018) · Theranostics · doi:10.7150/thno.27995 · Cited by 303
Development of NIR Fluorescent Dyes Based on Si–rhodamine for in Vivo Imaging
Koide, Y., Urano, Y., Hanaoka, K., Piao, W., Kusakabe, M., Saito, N., Terai, T., Okabe, T., & Nagano, T. (2012) · Journal of the American Chemical Society · doi:10.1021/ja210375e · Cited by 302
Albumin Carriers for Cancer Theranostics: A Conventional Platform with New Promise
Chen, Q., & Liu, Z. (2016) · Advanced Materials · doi:10.1002/adma.201600038 · Cited by 290
Lamberts, L. E., Koch, M., de Jong, J. S., Adams, A. L. L., Glatz, J., Kranendonk, M. E. G., Terwisscha van Scheltinga, A. G. T., Jansen, L., de Vries, J., Lub-de Hooge, M. N., et al. (2017) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-16-0437 · Cited by 285
Application of Near-Infrared Dyes for Tumor Imaging, Photothermal, and Photodynamic Therapies
Yuan, A., Wu, J., Tang, X., Zhao, L., Xu, F., & Hu, Y. (2013) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.23356 · Cited by 280
In vivo fluorescence imaging: success in preclinical imaging paves the way for clinical applications
Refaat, A., Yap, M. L., Pietersz, G., Walsh, A. P. G., Zeller, J., del Rosal, B., Wang, X., & Peter, K. (2022) · Journal of Nanobiotechnology · doi:10.1186/s12951-022-01648-7 · Cited by 266
Advanced Functional Nanomaterials for Theranostics
Huang, H., & Lovell, J. F. (2017) · Advanced Functional Materials · doi:10.1002/adfm.201603524 · Cited by 242
Successively activatable ultrasensitive probe for imaging tumour acidity and hypoxia
Zheng, X., Mao, H., Huo, D., Wu, W., Liu, B., & Jiang, X. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-017-0057 · Cited by 210
Shortwave-infrared (SWIR) emitters for biological imaging: a review of challenges and opportunities
Thimsen, E., Sadtler, B., & Berezin, M. Y. (2017) · Nanophotonics · doi:10.1515/nanoph-2017-0039 · Cited by 208
“Today, more than 20 NIR contrast agents, which can be either free or conjugated to monoclonal antibodies, have been used in clinical trials, and dedicated imaging systems have emerged such as FLARE [14], NIR goggles [15], Spy Elite (Novadaq) [16], da Vinci (Intuitive Surgical) [17] for clinical diagnostics, as well as…”
MethodHigh-quality quantum dots for multiplexed bioimaging: A critical review
Pandey, S., & Bodas, D. (2020) · Advances in Colloid and Interface Science · doi:10.1016/j.cis.2020.102137 · Cited by 196
Molecular imaging for personalized cancer care
Kircher, M. F., Hricak, H., & Larson, S. M. (2012) · Molecular Oncology · doi:10.1016/j.molonc.2012.02.005 · Cited by 193
“Intraoperative imaging systems have also been developed for visualization of sentinel lymph node mapping in breast cancer patients using ICG as a near infrared fluorescent lymphatic tracer (Troyan et al., 2009).”
MethodA review of performance of near-infrared fluorescence imaging devices used in clinical studies
Zhu, B., & Sevick-Muraca, E. M. (2015) · The British Journal of Radiology · doi:10.1259/bjr.20140547 · Cited by 175
Mérian, J., Gravier, J., Navarro, F., & Texier, I. (2012) · Molecules · doi:10.3390/molecules17055564 · Cited by 174
“The adsorption of ICG on Human Serum Albumin (HSA), forming nanocolloids of ≈7 nm diameter, has been reported to significantly prolong the fluorescence signal in the sentinel lymph node of breast cancer patients [12].”
BackgroundMethodInfluentialNiebling, M. G., Pleijhuis, R. G., Bastiaannet, E., Brouwers, A. H., van Dam, G. M., & Hoekstra, H. J. (2016) · European Journal of Surgical Oncology (EJSO) · doi:10.1016/j.ejso.2015.12.007 · Cited by 166
Systematic review of methods to predict and detect anastomotic leakage in colorectal surgery
Hirst, N. A., Tiernan, J. P., Millner, P. A., & Jayne, D. G. (2014) · Colorectal Disease · doi:10.1111/codi.12411 · Cited by 158
Tsai, W.-K., Wang, C.-I., Liao, C.-H., Yao, C.-N., Kuo, T.-J., Liu, M.-H., Hsu, C.-P., Lin, S.-Y., Wu, C.-Y., Pyle, J. R., et al. (2019) · Chemical Science · doi:10.1039/c8sc03510e · Cited by 79
Matsui, A., Winer, J. H., Laurence, R. G., & Frangioni, J. V. (2011) · British Journal of Surgery · doi:10.1002/bjs.7698 · Cited by 69
Self-citationAdvances in Diagnostic and Intraoperative Molecular Imaging of Pancreatic Cancer
Tummers, W. S., Willmann, J. K., Bonsing, B. A., Vahrmeijer, A. L., Gambhir, S. S., & Swijnenburg, R.-J. (2018) · Pancreas · doi:10.1097/mpa.0000000000001075 · Cited by 50
He, K., Chi, C., Kou, D., Huang, W., Wu, J., Wang, Y., He, L., Ye, J., Mao, Y., Zhang, G.-J., et al. (2016) · Translational Research · doi:10.1016/j.trsl.2016.07.010 · Cited by 46
Qi, B., Crawford, A. J., Wojtynek, N. E., Talmon, G. A., Hollingsworth, M. A., Ly, Q. P., & Mohs, A. M. (2020) · Theranostics · doi:10.7150/thno.40688 · Cited by 18
“The overall design and operation of this system have been previously reported [80].”
BackgroundLiu, M.-H., Chen, T.-C., Vicente, J. R., Yao, C.-N., Yang, Y.-C., Chen, C.-P., Lin, P.-W., Ho, Y.-C., Chen, J., Lin, S.-Y., et al. (2020) · ACS Applied Bio Materials · doi:10.1021/acsabm.0c00417 · Cited by 13
Metadata
- Authors
- Troyan, S. L., Kianzad, V., Gibbs-Strauss, S. L., Gioux, S., Matsui, A., Oketokoun, R., Ngo, L., Khamene, A., Azar, F., & Frangioni, J. V.
- Venue
- Annals of Surgical Oncology
- Published
- 2009-07-07
- Volume
- 16
- Issue
- 10
- Pages
- 2943-2952
- ISSN
- 1068-9265 (ISSN-L)
- 1534-4681
- OpenAlex
- W2168544783
- Cited by
- 684
- References
- 27
- FWCI
- 32.88
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.