Validation of a heart rate monitor with children in laboratory and field settings
The DOI matches its Crossref record.
Abstract
TREIBER, F. A., L. MUSANTE, S. HARTDAGAN, M. LEVY, and W. B. STRONG. Validation of a heart rate monitor with children in laboratory and field settings. Med. Sci. Sports Exerc., Vol. 21, No. 3, pp. 338–342, 1989. The validity of the Sport Tester PE 3000 portable heart rate monitor for use with children was assessed by comparing readings with simultaneously recorded ECG heart rates in three studies, two using laboratory tasks and one in a field setting. Study 1 examined the validity of the Sport Tester with a sample often 10-yr-olds performing a cycle ergometer exercise task. Sport Tester readings taken during three 3-min exercise loads were correlated from 0.97 to 0.99 with simultaneously recorded ECG heart rates. In study 2, 23 children from 4 to 6 yr of age performed treadmill exercise for three 1-min intervals while Sport Tester and ECG heart rate data were obtained. Correlations for the three intervals ranged from 0.94 to 0.99. Study 3 obtained ECG and Sport Tester heart rates in 14 7− to 9-yr-olds who engaged in 3-min periods of standing, walking, jogging, throwing a ball, batting a ball, and playing on a jungle gym. Significant correlations of at least 0.98 between Sport Tester and ECG heart rates were obtained during all six activities. For all three studies, standard errors of estimate were low, ranging from 1.1 to 3.7 beats·min-1. For individuals, maximum differences ranged from 0 to 12.4 beats·min-1. Collectively, these findings indicate that the Sport Tester provides valid readings of young children's heart rates across a wide range of exercise involving upper- and lower-body movements.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Measurement Issues in the Assessment of Physical Activity in Children
Welk, G. J., Corbin, C. B., & Dale, D. (2000) · Research Quarterly for Exercise and Sport · doi:10.1080/02701367.2000.11082788 · Cited by 782
Ekkekakis, P., & Lind, E. (2006) · International Journal of Obesity · doi:10.1038/sj.ijo.0803052 · Cited by 503
SALLIS, J. F., STRIKMILLER, P. K., HARSHA, D. W., FELDMAN, H. A., EHLINGER, S., STONE, E. J., WILLISTON, J., & WOODS, S. (1996) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199607000-00011 · Cited by 426
RAINE, A., VENABLES, P. H., & MEDNICK, S. A. (1997) · Journal of the American Academy of Child & Adolescent Psychiatry · doi:10.1097/00004583-199710000-00029 · Cited by 317
Evaluation of heart rate as a method for assessing moderate intensity physical activity
STRATH, S. J., SWARTZ, A. M., BASSETT, D. R., O???BRIEN, W. L., KING, G. A., & AINSWORTH, B. E. (2000) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200009001-00005 · Cited by 301
Tracking of physical activity in young children
PATE, R. R., BARANOWSKI, T., DOWDA, M., & TROST, S. G. (1996) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199601000-00019 · Cited by 293
Ekkekakis, P., Hall, E. E., & Petruzzello, S. J. (2004) · Preventive Medicine · doi:10.1016/j.ypmed.2003.09.038 · Cited by 228
“99 range and deviations from 1 to 12 beats min 1 [54,74,84,92].”
BackgroundStratton, G. (2000) · Ergonomics · doi:10.1080/001401300750003961 · Cited by 181
“Heart rate radio telemeters have been found to be valid (Treiber et al. 1989) and reliable when used as a measure of physical activity in young children throughout the day (Durant et al. 1992) and during playtime (Whitehurst et al. 1996).”
BackgroundLanguage, Learning, and Behavior Disorders: Developmental, Biological, and Clinical Perspectives
Fox, G. (1997) · Journal of the American Academy of Child & Adolescent Psychiatry · doi:10.1097/00004583-199710000-00031 · Cited by 161
Lind, E., Joens-Matre, R. R., & Ekkekakis, P. (2005) · Preventive Medicine · doi:10.1016/j.ypmed.2004.07.006 · Cited by 159
“[85] Treiber FA, Musante L, Hartdagan S, et al.”
BackgroundValidation of photoplethysmography as a method to detect heart rate during rest and exercise
Spierer, D. K., Rosen, Z., Litman, L. L., & Fujii, K. (2015) · Journal of Medical Engineering & Technology · doi:10.3109/03091902.2015.1047536 · Cited by 139
“Even monitors that are considered user-friendly and affordable and which have been validated at rest and during various levels and types of physical activity [31,32,40] may still prove difficult to use.”
BackgroundSimultaneous heart rate-motion sensor technique to estimate energy expenditure
STRATH, S. J., BASSETT, D. R., SWARTZ, A. M., & THOMPSON, D. L. (2001) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200112000-00022 · Cited by 134
Integration of physiological and accelerometer data to improve physical activity assessment
STRATH, S. J., BRAGE, S., & EKELUND, U. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185650.68232.3f · Cited by 126
The Effect of Aerobic Exercise Training on the Lipid-Lipoprotein Profile of Children and Adolescents
Tolfrey, K., Jones, A. M., & Campbell, I. G. (2000) · Sports Medicine · doi:10.2165/00007256-200029020-00003 · Cited by 125
Assessing the Wearability of Wearable Computers
Knight, J., Deen-Williams, D., Arvanitis, T., Baber, C., Sotiriou, S., Anastopoulou, S., & Gargalakos, M. (2006) · 2006 10th IEEE International Symposium on Wearable Computers · doi:10.1109/iswc.2006.286347 · Cited by 67
“These methods are considered to be highly reliable, easy to use and are tolerated by most user groups [10].”
The Relationship between Psychiatric Illness and the Circadian Pattern of Heart Rate
Stampfer, H. G. (1998) · Australian & New Zealand Journal of Psychiatry · doi:10.3109/00048679809062728 · Cited by 51
Pirrie, A. M., & Lodewyk, K. R. (2012) · Mental Health and Physical Activity · doi:10.1016/j.mhpa.2012.04.001 · Cited by 38
Metadata
- Authors
- TREIBER, F. A., MUSANTE, L., HARTDAGAN, S., DAVIS, H., LEVY, M., & STRONG, W. B.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 1989-06
- Volume
- 21
- Issue
- 3
- Pages
- 338???342
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W4300990195
- Cited by
- 83
- References
- 0
- FWCI
- 1.26
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.