Simultaneous measurement of heart rate and body motion to quantitate physical activity
The DOI matches its Crossref record.
Abstract
None of the various methods used to measure habitual physical activity over days, weeks, or years in the general population have yet proven entirely satisfactory. A major problem is that no "gold standard" exists for the validation of various questionnaires, logs, or diaries that can be used in large sample population studies. Attempts have been made to accurately measure the activity profile by using heart rate or various motion sensors or accelerometers, but each approach has had significant limitations. The availability of new solid state recording techniques and computer-based analytic and display procedures now makes it possible to simultaneously record heart rate and body movement continuously for days and to combine the analysis of these data using customized software. Preliminary evaluation of this concept of simultaneous recording and analysis of heart rate and body motion via movement sensors on an arm and leg were conducted in 19 men. Subjects performed a variety of exercises in the laboratory during which heart rate, leg motion, arm motion, and oxygen uptake were recorded. Various issues regarding the prediction of energy expenditure from heart rate and body movement independently and in combination were evaluated. The results demonstrate that the accuracy of estimating oxygen uptake during a wide range of activities is improved when individualized heart rate--oxygen uptake regressions are used and heart rate and body movement are analyzed simultaneously rather that separately.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Limits to the measurement of habitual physical activity by questionnaires
Shephard, R. J. (2003) · British Journal of Sports Medicine · doi:10.1136/bjsm.37.3.197 · Cited by 1,694
Strath, S. J., Kaminsky, L. A., Ainsworth, B. E., Ekelund, U., Freedson, P. S., Gary, R. A., Richardson, C. R., Smith, D. T., & Swartz, A. M. (2013) · Circulation · doi:10.1161/01.cir.0000435708.67487.da · Cited by 1,029
Chen, M. J., Fan, X., & Moe, S. T. (2002) · Journal of Sports Sciences · doi:10.1080/026404102320761787 · Cited by 819
Measurement Issues in the Assessment of Physical Activity in Children
Welk, G. J., Corbin, C. B., & Dale, D. (2000) · Research Quarterly for Exercise and Sport · doi:10.1080/02701367.2000.11082788 · Cited by 782
Validity of the computer science and applications (CSA) activity monitor in children
TROST, S. G., WARD, D. S., MOOREHEAD, S. M., WATSON, P. D., RINER, W., & BURKE, J. R. (1998) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199804000-00023 · Cited by 769
Reliability and validity of the combined heart rate and movement sensor Actiheart
Brage, S., Brage, N., Franks, P. W., Ekelund, U., & Wareham, N. J. (2005) · European Journal of Clinical Nutrition · doi:10.1038/sj.ejcn.1602118 · Cited by 667
Assessment of Physical Activity and Energy Expenditure: An Overview of Objective Measures
Hills, A. P., Mokhtar, N., & Byrne, N. M. (2014) · Frontiers in Nutrition · doi:10.3389/fnut.2014.00005 · Cited by 575
Brage, S., Brage, N., Franks, P. W., Ekelund, U., Wong, M.-Y., Andersen, L. B., Froberg, K., & Wareham, N. J. (2004) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00703.2003 · Cited by 473
Dowd, K. P., Szeklicki, R., Minetto, M. A., Murphy, M. H., Polito, A., Ghigo, E., van der Ploeg, H., Ekelund, U., Maciaszek, J., Stemplewski, R., et al. (2018) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-017-0636-2 · Cited by 385
The 24-Hour Activity Cycle: A New Paradigm for Physical Activity
ROSENBERGER, M. E., FULTON, J. E., BUMAN, M. P., TROIANO, R. P., GRANDNER, M. A., BUCHNER, D. M., & HASKELL, W. L. (2019) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001811 · Cited by 372
Self-citationSchuit, A. J., Schouten, E. G., Westerterp, K. R., & Saris, W. H. M. (1997) · Journal of Clinical Epidemiology · doi:10.1016/s0895-4356(97)00010-3 · Cited by 337
Validity and Reliability issues in Objective Monitoring of Physical Activity
Bassett, D. R. (2000) · Research Quarterly for Exercise and Sport · doi:10.1080/02701367.2000.11082783 · Cited by 326
Verbunt, J. A., Seelen, H. A., Vlaeyen, J. W., van de Heijden, G. J., Heuts, P. H., Pons, K., & Knottnerus, J. A. (2003) · European Journal of Pain · doi:10.1016/s1090-3801(02)00071-x · Cited by 318
Ainslie, P. N., Reilly, T., & Westerterp, K. R. (2003) · Sports Medicine · doi:10.2165/00007256-200333090-00004 · Cited by 309
Aminian, K., Robert, P., Buchser, E. E., Rutschmann, B., Hayoz, D., & Depairon, M. (1999) · Medical & Biological Engineering & Computing · doi:10.1007/bf02513304 · Cited by 308
Brage, S., Ekelund, U., Brage, N., Hennings, M. A., Froberg, K., Franks, P. W., & Wareham, N. J. (2007) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00092.2006 · Cited by 303
Quantifying energy expenditure and physical activity in the context of dose response
LAMONTE, M. J., & AINSWORTH, B. E. (2001) · Medicine and Science in Sports and Exercise · doi:10.1097/00005768-200106001-00006 · Cited by 299
Calibration and Validation of Wearable Monitors
BASSETT, D. R., ROWLANDS, A., & TROST, S. G. (2012) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3182399cf7 · Cited by 292
Accuracy of the Actiheart for the assessment of energy expenditure in adults
Crouter, S. E., Churilla, J. R., & Bassett, D. R. (2008) · European Journal of Clinical Nutrition · doi:10.1038/sj.ejcn.1602766 · Cited by 236
Physical activity assessment: A review of methods
Melanson, E. L., Freedson, P. S., & Blair, S. (1996) · Critical Reviews in Food Science and Nutrition · doi:10.1080/10408399609527732 · Cited by 223
Comparison of PAEE from Combined and Separate Heart Rate and Movement Models in Children
Corder, K., Brage, S., Wareham, N. J., & Ekelund, U. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000176466.78408.cc · Cited by 170
Brage, S., Westgate, K., Franks, P. W., Stegle, O., Wright, A., Ekelund, U., & Wareham, N. J. (2015) · PLOS ONE · doi:10.1371/journal.pone.0137206 · Cited by 151
“For the assessment of PAEE, previous studies have demonstrated the advantage of integrating physiological measures, like heart rate (HR), with biomechanical measures such as acceleration (ACC) or other motion sensing [5–12].”
Validation of photoplethysmography as a method to detect heart rate during rest and exercise
Spierer, D. K., Rosen, Z., Litman, L. L., & Fujii, K. (2015) · Journal of Medical Engineering & Technology · doi:10.3109/03091902.2015.1047536 · Cited by 139
“combined with heart rate data improves estimates of energy consumption and expenditure [21–23].”
BackgroundSimultaneous heart rate-motion sensor technique to estimate energy expenditure
STRATH, S. J., BASSETT, D. R., SWARTZ, A. M., & THOMPSON, D. L. (2001) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200112000-00022 · Cited by 134
Thompson, D., Batterham, A. M., Bock, S., Robson, C., & Stokes, K. (2006) · The Journal of Nutrition · doi:10.1093/jn/136.4.1037 · Cited by 129
Brage, S., Brage, N., Ekelund, U., Luan, J., Franks, P. W., Froberg, K., & Wareham, N. J. (2006) · European Journal of Applied Physiology · doi:10.1007/s00421-005-0112-6 · Cited by 127
“…Fax: +44-1223-330316 N. Brage Æ K. Froberg Institute of Sports Science and Clinical Biomechanics, University of Southern Denmark, Odense, Denmark Haskell et al. 1993; Moon and Butte 1996; Rennie et al. 2000; Strath et al. 2001 but the advantage of adding a measure of HR to movement…”
BackgroundIntegration of physiological and accelerometer data to improve physical activity assessment
STRATH, S. J., BRAGE, S., & EKELUND, U. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185650.68232.3f · Cited by 126
A combined heart rate and movement sensor: proof of concept and preliminary testing study
Rennie, K., Rowsell, T., Jebb, S., Holburn, D., & Wareham, N. (2000) · European Journal of Clinical Nutrition · doi:10.1038/sj.ejcn.1600973 · Cited by 83
“…potential criticism of the heart rate monitoring technique is that it is not possible to differentiate between increases in heart rate due to activity or those due to stress (Haskell et al, 1993; Montoye & Taylor, 1984; Meijer et al, 1989), especially when the increase in heart rate is modest.”
BackgroundMethodResultOccupational physical activity in brewery and office workers
Thompson, J. F., Severson, R. L., & Rosecrance, J. C. (2018) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2018.1492136 · Cited by 9
Metadata
- Authors
- HASKELL, W. L., YEE, M. C., EVANS, A., & IRBY, P. J.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 1993-01
- Volume
- 25
- Issue
- 1
- Pages
- 109-115
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2007794812
- Cited by
- 155
- References
- 0
- FWCI
- 1.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.