methods Evaluation of body composition by dual energy x-ray absorptiometry and two different software packages
The DOI matches its Crossref record.
Abstract
VAN LOAN, M. D., N. L. KEIM, K. BERG, and P. L. MAYCLIN. Evaluation of body composition by dual energy x-ray absorptiometry. Med. Sci. Sports Exerc., Vol. 27, No. 4, pp. 587–591. Dual energy x-ray absorptiometry (DXA) measures body composition, tissue distribution, bone mineral content (BMC), and bone mineral density (BMD). Differences are possible due to software versions. This investigation examined body composition, tissue distribution, BMC, and BMD measurements using a DXA (Lunar Corp., Madison, WI) with different software packages (versions 3.4 and 3.6R). Fifteen women, ages 20–40 yr, enrolled in a weight-loss study (body mass index = 28) and volunteered for body composition assessment by densitometry. BMC, BMD, and tissue distribution measurements were made using DXA. Results were analyzed once each with software versions 3.4 and 3.6R. BMC + total soft tissue, measured using DXA, was comparable to measured body weight (3.4 = 76.3 kg; 3.6R = 76.5 kg; weight = 76.5 kg). Lower BMC and BMD (5.5% and 1.8%, P > 0.01) were observed with 3.6R. Arm tissue mass was lower (1,530 g; P > 0.01) and fat declined (1,069 g; P > 0.01) with 3.6R. Leg tissue mass decreased 487 g (P > 0.01), but fat tissue increased (526 g, P > 0.01) with 3.6R. A larger fat mass (1,492 g) and lower lean mass (1,115 g) were observed with 3.6R compared with 3.4. Percent fat values by densitometry using DXA 3.4 and 3.6R were 38.1%, 39.9, and 41.9%, respectively. These results demonstrated differences in total body composition, lean and fat tissue distribution, and bone measurements from DXA software versions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Body-composition assessment via air-displacement plethysmography in adults and children: a review
Fields, D. A., Goran, M. I., & McCrory, M. A. (2002) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/75.3.453 · Cited by 638
Nana, A., Slater, G. J., Stewart, A. D., & Burke, L. M. (2015) · International Journal of Sport Nutrition and Exercise Metabolism · doi:10.1123/ijsnem.2013-0228 · Cited by 372
Glickman, S. G., Marn, C. S., Supiano, M. A., & Dengel, D. R. (2004) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01234.2003 · Cited by 274
Body composition of a young, multiethnic female population
Ellis, K., Abrams, S., & Wong, W. (1997) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/65.3.724 · Cited by 252
Advances in muscle health and nutrition: A toolkit for healthcare professionals
Prado, C. M., Landi, F., Chew, S. T. H., Atherton, P. J., Molinger, J., Ruck, T., & Gonzalez, M. C. (2022) · Clinical Nutrition · doi:10.1016/j.clnu.2022.07.041 · Cited by 237
Dual-energy X-ray absorptiometry and body composition
Plank, L. D. (2005) · Current Opinion in Clinical Nutrition & Metabolic Care · doi:10.1097/01.mco.0000165010.31826.3d · Cited by 185
Genton, L., Hans, D., Kyle, U. G., & Pichard, C. (2002) · Nutrition · doi:10.1016/s0899-9007(01)00700-6 · Cited by 175
Pediatric body composition analysis with dual-energy X-ray absorptiometry.
Helba, M., & Binkovitz, L. A. (2009) · Pediatric Radiology · doi:10.1007/s00247-009-1247-0 · Cited by 127
“These assumptions, many of which are proprietary, differ among DXA manufacturers [22, 23] and the software used for analysis [24], and thus comparison of BCA results require careful attention to equipment and software differences.”
BackgroundModlesky, C. M., Bickel, C. S., Slade, J. M., Meyer, R. A., Cureton, K. J., & Dudley, G. A. (2004) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00207.2003 · Cited by 124
Teigen, L. M., Kuchnia, A. J., Mourtzakis, M., & Earthman, C. P. (2017) · Nutrition in Clinical Practice · doi:10.1177/0884533616676264 · Cited by 75
Tothill, P., Hannan, W. J., & Wilkinson, S. (2001) · The British Journal of Radiology · doi:10.1259/bjr.74.878.740166 · Cited by 71
Impact of bone mineral estimates on percent fat estimates from a four-component model
MODLESKY, C. M., EVANS, E. M., MILLARD-STAFFORD, M. L., COLLINS, M. A., LEWIS, R. D., & CURETON, K. J. (1999) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199912000-00026 · Cited by 24
Metadata
- Authors
- VAN LOAN, M. D., KEIM, N. L., BERG, K., & MAYCLIN, P. L.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 1995-04
- Volume
- 27
- Issue
- 4
- Pages
- 587???591
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W4291475556
- Cited by
- 37
- References
- 0
- FWCI
- 0.84
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.