Intermonitor Variability of the RT3 Accelerometer during Typical Physical Activities
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
PURPOSE: To evaluate the reliability and variability of eight RT3 accelerometers. METHODS: The RT3 were subjected to two repeated trials of six activities: rest, walking (4 and 6 km.h-1), running (8 and 10 km.h-1), and sit-stand position (20 min). One person performed all trials (female: age 24 yr, height 158.0 cm, mass 48.2 kg). Each activity lasted 12 min. The middle 10 min were taken from each 12-min trial and used as the output measure (cts.min-1). Data were analyzed for activity ( 6), monitor ( 8), and trial ( 2) effects using four three-way ANOVA: vector magnitude, X (vertical), Y (anterioposterior), and Z (mediolateral) axes. RESULTS: Intermonitor coefficient of variation was <6% during locomotive activities, however, increased to 8-25% during sit-stand. A three-way interaction was found for vector magnitude (F35,315=88945.7, P < 0.001) and Y (F35,315=978435.6, P < 0.001) and Z axes (F35,315=103802.8, P < 0.001). A two-way activity x monitor interaction was found for the X axis (F35,315=1037787.0, P < 0.001). Follow-up tests revealed no differences between trials 1 and 2 for vector magnitude, X and Z axes. One monitor recorded significantly lower activity counts in trial 1 compared with trial 2 along the Y axis. Intermonitor differences were evident at 4, 6, 8, and 10 km.h-1 for the Y and Z axes, and at 6, 8, and 10 km.h-1 for the vector magnitude and X axis. Variability between monitors at each activity increased as intensity increased. CONCLUSION: Reliability of the RT3 is good; however, intermonitor variability exists. The vertical axis of the RT3 accelerometer showed the least variability and was the most reliable. It is recommended that intermonitor variability and reliability of RT3 on each axis be assessed before use.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Validity of the computer science and applications (CSA) activity monitor in children
TROST, S. G., WARD, D. S., MOOREHEAD, S. M., WATSON, P. D., RINER, W., & BURKE, J. R. (1998) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199804000-00023 · Cited by 769
Eston, R. G., Rowlands, A. V., & Ingledew, D. K. (1998) · Journal of Applied Physiology · doi:10.1152/jappl.1998.84.1.362 · Cited by 643
Self-citation
Cited by
Conducting accelerometer-based activity assessments in field-based research
TROST, S. G., MCIVER, K. L., & PATE, R. R. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185657.86065.98 · Cited by 2,033
Strath, S. J., Kaminsky, L. A., Ainsworth, B. E., Ekelund, U., Freedson, P. S., Gary, R. A., Richardson, C. R., Smith, D. T., & Swartz, A. M. (2013) · Circulation · doi:10.1161/01.cir.0000435708.67487.da · Cited by 1,029
The Reliability of MinimaxX Accelerometers for Measuring Physical Activity in Australian Football
Boyd, L. J., Ball, K., & Aughey, R. J. (2011) · International Journal of Sports Physiology and Performance · doi:10.1123/ijspp.6.3.311 · Cited by 556
Quantifying physical activity in daily life with questionnaires and motion sensors in COPD
Pitta, F., Troosters, T., Probst, V. S., Spruit, M. A., Decramer, M., & Gosselink, R. (2006) · European Respiratory Journal · doi:10.1183/09031936.06.00064105 · Cited by 473
State of the Art Reviews: Measurement of Physical Activity in Children and Adolescents
Trost, S. G. (2007) · American Journal of Lifestyle Medicine · doi:10.1177/1559827607301686 · Cited by 404
Dowd, K. P., Szeklicki, R., Minetto, M. A., Murphy, M. H., Polito, A., Ghigo, E., van der Ploeg, H., Ekelund, U., Maciaszek, J., Stemplewski, R., et al. (2018) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-017-0636-2 · Cited by 385
“For the laboratory-based studies, variables examined included distance walked [282], steps at different speeds [314, 420], resting periods [358], accelerometer counts [385, 407, 411, 414, 416, 425, 429, 430], energy expenditure [426] and postural position [297, 429].”
MethodValidation of the RT3 Triaxial Accelerometer for the Assessment of Physical Activity
ROWLANDS, A. V., THOMAS, P. W. M., ESTON, R. G., & TOPPING, R. (2004) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000117158.14542.e7 · Cited by 343
Self-citationMurphy, S. L. (2009) · Preventive Medicine · doi:10.1016/j.ypmed.2008.12.001 · Cited by 326
Validation of a physical activity assessment tool for individuals with schizophrenia
Faulkner, G., Cohn, T., & Remington, G. (2006) · Schizophrenia Research · doi:10.1016/j.schres.2005.10.020 · Cited by 251
“activity (DeVoe et al., 2003; Powell and Rowlands, 2004; Rowlands et al., 2004).”
Soundy, A., Roskell, C., Stubbs, B., & Vancampfort, D. (2014) · Archives of Psychiatric Nursing · doi:10.1016/j.apnu.2013.12.002 · Cited by 131
Protocols for evaluating equivalency of accelerometry-based activity monitors
WELK, G. J., MCCLAIN, J., & AINSWORTH, B. E. (2012) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3182399d8f · Cited by 124
“, walking on a treadmill) or assess the reliability of two monitors positioned on the right and left sides of the body (19,25,26,30,33).”
BackgroundHale, L. A., Pal, J., & Becker, I. (2008) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2008.02.027 · Cited by 118
Methodology for Using Long-Term Accelerometry Monitoring to Describe Daily Activity Patterns in COPD
Hecht, A., Ma, S., Porszasz, J., Casaburi, R., & Netw, F. T. C. C. R. (2009) · COPD: Journal of Chronic Obstructive Pulmonary Disease · doi:10.1080/15412550902755044 · Cited by 91
“Although a previous study discerned no difference between right and left hip placement (22), subjects were asked to wear the monitor on their non-dominant hip.”
BackgroundEffects of weight gain induced by controlled overfeeding on physical activity
Apolzan, J. W., Bray, G. A., Smith, S. R., de Jonge, L., Rood, J., Han, H., Redman, L. M., & Martin, C. K. (2014) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.00386.2014 · Cited by 28
“The RT3 accelerometer (Stayhealthy, Monrovia, CA) was worn at the waist during baseline (21, 26) and for the duration of the overfeeding study, except during certain procedures [dual-energy X-ray absorptiometry (DEXA), computed tomography, clamp etc.”
Method
Metadata
- Authors
- POWELL, S. M., & ROWLANDS, A. V.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 2004-02
- Volume
- 36
- Issue
- 2
- Pages
- 324-330
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2048222657
- Cited by
- 105
- References
- 2
- FWCI
- 3.61
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.