Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 343

The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.

Validation of the RT3 Triaxial Accelerometer for the Assessment of Physical Activity

ROWLANDS, ANN V., THOMAS, PHILIP W. M., ESTON, ROGER G., TOPPING, RODNEY · 2004 · Medicine & Science in Sports & Exercise

Abstract

PURPOSE: The aims of this study were to assess and compare the validity of the RT3 accelerometer for the assessment of physical activity in boys and men, to compare RT3 and Tritrac accelerometer counts, and to determine count cut-off values for moderate (> or =3 < 6 METs) and vigorous (> or =6 METs) activity. METHODS: Nineteen boys (age: 9.5 +/- 0.8 yr) and 15 men (age: 20.7 +/- 1.4 yr) walked and ran on a treadmill, kicked a ball to and fro, played hopscotch, and sat quietly. An RT3 was worn on the right hip; boys also wore a Tritrac on the left hip. Oxygen consumption was expressed as a ratio of body mass raised to the power of 0.75 (S VO2). RESULTS: RT3 counts correlated significantly with S VO2 in boys (r = 0.87, P < 0.01) and men (r = 0.85, P < 0.01). However, during treadmill activities, RT3 counts were significantly higher for boys (P < 0.05). RT3 counts corresponding to "moderate" and "vigorous" activity were similar for boys and men for all activities (moderate = 970.2 for boys and 984.0 for men; vigorous = 2333.0 for boys and 2340.8 for men) but approximately 400 counts lower in men when only treadmill activities were considered. Tritrac counts correlated significantly with S VO2 in boys (r = 0.87, P < 0.01), but were significantly lower than RT3 counts across most activities (P < 0.05). CONCLUSIONS: The RT3 accelerometer is a good measure of physical activity for boys and men. However, moderate and vigorous intensity count thresholds differ for boys and men when the predominant activities are walking and running. RT3 counts are significantly higher than Tritrac counts for a number of activities. These findings have implications when comparing activity counts between studies using the different instruments.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1249/01.mss.0000117158.14542.e7

Cites

19 of 19 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 19 references

Cited by

See all 343

Metadata

Authors
ROWLANDS, A. V., THOMAS, P. W. M., ESTON, R. G., & TOPPING, R.
Venue
Medicine & Science in Sports & Exercise
Published
2004-03
Volume
36
Issue
3
Pages
518-524
ISSN
0195-9131 (ISSN-L)
OpenAlex
W2054131260
Cited by
343
References
19
FWCI
8.55
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Validation of the RT3 Triaxial Accelerometer for the Assessment of Physical Activity. https://app.cochat.ai/papers/10.1249/01.mss.0000117158.14542.e7
The paper
ROWLANDS, A. V., THOMAS, P. W. M., ESTON, R. G., & TOPPING, R. (2004). Validation of the RT3 Triaxial Accelerometer for the Assessment of Physical Activity. Medicine & Science in Sports & Exercise. https://doi.org/10.1249/01.mss.0000117158.14542.e7

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.