The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Validation of the RT3 Triaxial Accelerometer for the Assessment of Physical Activity
Abstract
PURPOSE: The aims of this study were to assess and compare the validity of the RT3 accelerometer for the assessment of physical activity in boys and men, to compare RT3 and Tritrac accelerometer counts, and to determine count cut-off values for moderate (> or =3 < 6 METs) and vigorous (> or =6 METs) activity. METHODS: Nineteen boys (age: 9.5 +/- 0.8 yr) and 15 men (age: 20.7 +/- 1.4 yr) walked and ran on a treadmill, kicked a ball to and fro, played hopscotch, and sat quietly. An RT3 was worn on the right hip; boys also wore a Tritrac on the left hip. Oxygen consumption was expressed as a ratio of body mass raised to the power of 0.75 (S VO2). RESULTS: RT3 counts correlated significantly with S VO2 in boys (r = 0.87, P < 0.01) and men (r = 0.85, P < 0.01). However, during treadmill activities, RT3 counts were significantly higher for boys (P < 0.05). RT3 counts corresponding to "moderate" and "vigorous" activity were similar for boys and men for all activities (moderate = 970.2 for boys and 984.0 for men; vigorous = 2333.0 for boys and 2340.8 for men) but approximately 400 counts lower in men when only treadmill activities were considered. Tritrac counts correlated significantly with S VO2 in boys (r = 0.87, P < 0.01), but were significantly lower than RT3 counts across most activities (P < 0.05). CONCLUSIONS: The RT3 accelerometer is a good measure of physical activity for boys and men. However, moderate and vigorous intensity count thresholds differ for boys and men when the predominant activities are walking and running. RT3 counts are significantly higher than Tritrac counts for a number of activities. These findings have implications when comparing activity counts between studies using the different instruments.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Comparing correlated correlation coefficients
Meng, X.-L., Rosenthal, R., & Rubin, D. B. (1992) · Psychological Bulletin · doi:10.1037/0033-2909.111.1.172 · Cited by 2,472
Eston, R. G., Rowlands, A. V., & Ingledew, D. K. (1998) · Journal of Applied Physiology · doi:10.1152/jappl.1998.84.1.362 · Cited by 643
Self-citationValidity of four motion sensors in measuring moderate intensity physical activity
BASSETT, D. R. (2000) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200009001-00006 · Cited by 527
Estimation of energy expenditure using CSA accelerometers at hip and wrist sites
SWARTZ, A. M., STRATH, S. J., BASSETT, D. R., O???BRIEN, W. L., KING, G. A., & AINSWORTH, B. E. (2000) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200009001-00003 · Cited by 513
Assessment of energy expenditure for physical activity using a triaxial accelerometer
BOUTEN, C. V., WESTERTERP, K. R., VERDUIN, M., & JANSSEN, J. D. (1994) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-199412000-00016 · Cited by 451
Validity of the Computer Science and Applications, Inc. (CCA) activity monitor
MELANSON, E. L., & FREEDSON, P. S. (1995) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-199506000-00021 · Cited by 416
Validity and Reliability issues in Objective Monitoring of Physical Activity
Bassett, D. R. (2000) · Research Quarterly for Exercise and Sport · doi:10.1080/02701367.2000.11082783 · Cited by 326
Relationship between activity levels, aerobic fitness, and body fat in 8- to 10-yr-old children
Rowlands, A. V., Eston, R. G., & Ingledew, D. K. (1999) · Journal of Applied Physiology · doi:10.1152/jappl.1999.86.4.1428 · Cited by 299
Self-citationNichols, J. F., Morgan, C. G., Chabot, L. E., Sallis, J. F., & Calfas, K. J. (2000) · Research Quarterly for Exercise and Sport · doi:10.1080/02701367.2000.10608878 · Cited by 203
Rowlands, A. V., Eston, R. G., & Ingledew, D. K. (1997) · Sports Medicine · doi:10.2165/00007256-199724040-00004 · Cited by 203
Self-citationAssessment of energy expenditure by recording heart rate and body acceleration
Meijer, G. A. L., Westerterp, K. R., Koper, H. B. M., & ten Hoor, F. (1989) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-198906000-00020 · Cited by 129
Field trial of a three-dimensional activity monitor: comparison with self report
Matthews, C. E., & Freedson, P. S. (1995) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-199507000-00017 · Cited by 126
The Use of Uniaxial and Triaxial Accelerometers to Measure Children’s “Free-Play” Physical Activity
Ott, A. E., Pate, R. R., Trost, S. G., Ward, D. S., & Saunders, R. P. (2000) · Pediatric Exercise Science · doi:10.1123/pes.12.4.360 · Cited by 123
Technical Variability of the RT3 Accelerometer
Powell, S. M., Jones, D. B., & Rowlands, A. V. (2003) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000089341.68754.ba · Cited by 121
Self-citationIntermonitor Variability of the RT3 Accelerometer during Typical Physical Activities
Powell, S. M., & Rowlands, A. V. (2004) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000113743.68789.36 · Cited by 119
Self-citationComparison of MTI Accelerometer Cut-Points for Predicting Time Spent in Physical Activity
Strath, S. J., Bassett, D. R., & Swartz, A. M. (2003) · International Journal of Sports Medicine · doi:10.1055/s-2003-39504 · Cited by 110
Scaling for the VO2-to-body size relationship among children and adults
Rogers, D. M., Olson, B. L., & Wilmore, J. H. (1995) · Journal of Applied Physiology · doi:10.1152/jappl.1995.79.3.958 · Cited by 105
Louie, L. H.-T., Eston, R. G., Rowlands, A. V., Tong, K. K., Ingledew, D. K., & Fu, F. H. K. (1999) · Pediatric Exercise Science · doi:10.1123/pes.11.3.229 · Cited by 76
Self-citationStride Frequency and Submaximal Treadmill Running Economy in Adults and Children
Unnithan, V. B., & Eston, R. G. (1990) · Pediatric Exercise Science · doi:10.1123/pes.2.2.149 · Cited by 38
Self-citation
Cited by
Molecular Mechanisms of Depression: Perspectives on New Treatment Strategies
Lang, U. E., & Borgwardt, S. (2013) · Cellular Physiology and Biochemistry · doi:10.1159/000350094 · Cited by 8,475
Calibration of Accelerometer Output for Children
FREEDSON, P., POBER, D., & JANZ, K. F. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185658.28284.ba · Cited by 1,104
Strath, S. J., Kaminsky, L. A., Ainsworth, B. E., Ekelund, U., Freedson, P. S., Gary, R. A., Richardson, C. R., Smith, D. T., & Swartz, A. M. (2013) · Circulation · doi:10.1161/01.cir.0000435708.67487.da · Cited by 1,029
A Review of Accelerometry-Based Wearable Motion Detectors for Physical Activity Monitoring
Yang, C.-C., & Hsu, Y.-L. (2010) · Sensors · doi:10.3390/s100807772 · Cited by 1,058
Direct measurement of human movement by accelerometry
Godfrey, A., Conway, R., Meagher, D., & ÓLaighin, G. (2008) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2008.09.005 · Cited by 591
Metadata
- Authors
- ROWLANDS, A. V., THOMAS, P. W. M., ESTON, R. G., & TOPPING, R.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 2004-03
- Volume
- 36
- Issue
- 3
- Pages
- 518-524
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2054131260
- Cited by
- 343
- References
- 19
- FWCI
- 8.55
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.