The Accuracy of Pedometer Steps and Time during Walking in Children
The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Abstract
Purpose: To determine the accuracy of pedometer step counts and time during self-paced walking (SPW) and treadmill walking in children (5–11 yr). Two pedometers were assessed during SPW: Digiwalker SW-200 (DW200) and Walk4Life 2505 (WL), and four pedometers during treadmill walking: DW200, WL, Digiwalker SW-701 (DW701), and the Sun TrekLINQ (SUN). Methods: Ten boys (8.3 ± 1.5 yr) and 10 girls (8.9 ± 1.7 yr) completed three single-lap SPW trials around an outdoor athletic track. Treadmill walking was performed at the following speeds: 40, 54, 67, 80, and 94 m·min−1. During treadmill walking, each model was measured on the right and left sides. Pedometer steps and time and observed steps and time were recorded for all trials. Results: Across SPW trials, there was high agreement on observed steps for both the DW200 and WL (intraclass correlation coefficient (ICC) 0.985–0.997). For treadmill walking, at ≤54 m·min−1, low interunit agreement (ICC ≤ 0.746) and low agreement between pedometer steps and observed steps (ICC ≤ 0.720) were detected for all models. For pedometer time, the WL exhibited a high level of agreement with observed during SPW (ICC 0.997–0.998). During treadmill walking, the WL was within 5.3% of actual time across all speeds, whereas time with the SUN did not come within 5% agreement until 80 m·min−1. Conclusions: Findings are consistent with adult studies with step count underestimation during slow (≤54 m·min−1) walking. Low interunit agreement at slow speeds suggests variations in step count registry within models. The accuracy of time (WL), independent of step count accuracy and speed, suggests that time might be used in addition to steps to quantify the physical activity behavior of children.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Assessment of physical activity by self-report: Status, limitations, and future directions
Sallis, J. F., & Saelens, B. E. (2000) · Research Quarterly for Exercise and Sport · doi:10.1080/02701367.2000.11082780 · Cited by 2,351
Age and gender differences in objectively measured physical activity in youth
TROST, S. G., PATE, R. R., SALLIS, J. F., FREEDSON, P. S., TAYLOR, W. C., DOWDA, M., & SIRARD, J. (2002) · Medicine and Science in Sports and Exercise · doi:10.1097/00005768-200202000-00025 · Cited by 1,451
The level and tempo of children???s physical activities: an observational study
BAILEY, R. C., OLSON, J., PEPPER, S. L., PORSZASZ, J., BARSTOW, T. J., & COOPER, D. M. (1995) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-199507000-00012 · Cited by 977
Validity of 10 Electronic Pedometers for Measuring Steps, Distance, and Energy Cost
CROUTER, S. E., SCHNEIDER, P. L., KARABULUT, M., & BASSETT, D. R. (2003) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000078932.61440.a2 · Cited by 899
Measurement Issues in the Assessment of Physical Activity in Children
Welk, G. J., Corbin, C. B., & Dale, D. (2000) · Research Quarterly for Exercise and Sport · doi:10.1080/02701367.2000.11082788 · Cited by 782
Pedometer Measures of Free-Living Physical Activity: Comparison of 13 Models
SCHNEIDER, P. L., CROUTER, S. E., & BASSETT, D. R. (2004) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000113486.60548.e9 · Cited by 752
Utility of Pedometers for Assessing Physical Activity: Convergent Validity
Tudor-Locke, C., Williams, J. E., Reis, J. P., & Pluto, D. (2002) · Sports Medicine · doi:10.2165/00007256-200232120-00004 · Cited by 649
Eston, R. G., Rowlands, A. V., & Ingledew, D. K. (1998) · Journal of Applied Physiology · doi:10.1152/jappl.1998.84.1.362 · Cited by 643
Accuracy and Reliability of 10 Pedometers for Measuring Steps over a 400-m Walk
SCHNEIDER, P. L., CROUTER, S. E., LUKAJIC, O., & BASSETT, D. R. (2003) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000089342.96098.c4 · Cited by 633
Accuracy of five electronic pedometers for measuring distance walked
BASSETT, D. R., AINSWORTH, B. E., LEGGETT, S. R., MATHIEN, C. A., MAIN, J. A., HUNTER, D. C., & DUNCAN, G. E. (1996) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199608000-00019 · Cited by 552
Cavill, N., Biddle, S., & Sallis, J. F. (2001) · Pediatric Exercise Science · doi:10.1123/pes.13.1.12 · Cited by 458
BMI-referenced standards for recommended pedometer-determined steps/day in children
Tudor-Locke, C., Pangrazi, R. P., Corbin, C. B., Rutherford, W. J., Vincent, S. D., Raustorp, A., Tomson, L. M., & Cuddihy, T. F. (2004) · Preventive Medicine · doi:10.1016/j.ypmed.2003.12.018 · Cited by 347
Relationship between activity levels, aerobic fitness, and body fat in 8- to 10-yr-old children
Rowlands, A. V., Eston, R. G., & Ingledew, D. K. (1999) · Journal of Applied Physiology · doi:10.1152/jappl.1999.86.4.1428 · Cited by 299
Measurement of daily walking distance-questionnaire versus pedometer
BASSETT, D. R. (2000) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200005000-00021 · Cited by 260
Utility of Pedometers for Assessing Physical Activity: Construct Validity
Tudor-Locke, C. E., Williams, J. E., Reis, J. P., & Pluto, D. M. (2004) · Sports Medicine · doi:10.2165/00007256-200434050-00001 · Cited by 250
Pedometer Accuracy in Nursing Home and Community-Dwelling Older Adults
CYARTO, E. V., MYERS, A. M., & TUDOR-LOCKE, C. (2004) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000113476.62469.98 · Cited by 236
Motion Sensor Accuracy under Controlled and Free-Living Conditions
LE MASURIER, G. C., LEE, S. M., & TUDOR-LOCKE, C. (2004) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000126777.50188.73 · Cited by 229
Rowlands, A. V., Eston, R. G., & Ingledew, D. K. (1997) · Sports Medicine · doi:10.2165/00007256-199724040-00004 · Cited by 203
Validity and Reliability of Activity Measures in African-American Girls for GEMS
TREUTH, M. S., SHERWOOD, N. E., BUTTE, N. F., MCCLANAHAN, B., OBARZANEK, E., ZHOU, A., AYERS, C., ADOLPH, A., JORDAN, J., JACOBS, D. R., et al. (2003) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000053702.03884.3f · Cited by 184
How “Significant” is Your Reliability?
Morrow, J. R., & Jackson, A. W. (1993) · Research Quarterly for Exercise and Sport · doi:10.1080/02701367.1993.10608821 · Cited by 176
Does Reactivity Exist in Children When Measuring Activity Levels with Pedometers?
Vincent, S. D., & Pangrazi, R. P. (2002) · Pediatric Exercise Science · doi:10.1123/pes.14.1.56 · Cited by 152
Quantifying Physical Activity via Pedometry in Elementary Physical Education
SCRUGGS, P. W., BEVERIDGE, S. K., EISENMAN, P. A., WATSON, D. L., SHULTZ, B. B., & RANSDELL, L. B. (2003) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000069748.02525.b2 · Cited by 142
Determining Measurement Error in Digital Pedometers
Vincent, S., & Sidman, C. (2003) · Measurement in Physical Education and Exercise Science · doi:10.1207/s15327841mpee0701_2 · Cited by 131
Validation of an Electronic Pedometer for Measurement of Physical Activity in Children
Kilanowski, C. K., Consalvi, A. R., & Epstein, L. H. (1999) · Pediatric Exercise Science · doi:10.1123/pes.11.1.63 · Cited by 120
Louie, L., Eston, R. G., Rowlands, A. V., Tong, K. K., Ingledew, D. K., & Fu, F. H. (1999) · Pediatric Exercise Science · doi:10.1123/pes.11.3.229 · Cited by 76
Interinstrument Consistency of the Yamax Digi-Walker Pedometer in Elementary School-Aged Children
Barfield, J. P., Rowe, D. A., & Michael, T. J. (2004) · Measurement in Physical Education and Exercise Science · doi:10.1207/s15327841mpee0802_5 · Cited by 65
Children’s Understanding of the Concept of Physical Activity
Trost, S. G., Morgan, A. M., Saunders, R. P., Felton, G., Ward, D. S., & Pate, R. R. (2000) · Pediatric Exercise Science · doi:10.1123/pes.12.3.293 · Cited by 55
Cited by
Assessment of physical activity in youth
Corder, K., Ekelund, U., Steele, R. M., Wareham, N. J., & Brage, S. (2008) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00094.2008 · Cited by 581
The validity and reliability of a novel activity monitor as a measure of walking
Ryan, C. G., Grant, P. M., Tigbe, W. W., & Granat, M. H. (2006) · British Journal of Sports Medicine · doi:10.1136/bjsm.2006.027276 · Cited by 490
State of the Art Reviews: Measurement of Physical Activity in Children and Adolescents
Trost, S. G. (2007) · American Journal of Lifestyle Medicine · doi:10.1177/1559827607301686 · Cited by 404
Reliability and validity of ten consumer activity trackers
Kooiman, T. J. M., Dontje, M. L., Sprenger, S. R., Krijnen, W. P., van der Schans, C. P., & de Groot, M. (2015) · BMC Sports Science, Medicine and Rehabilitation · doi:10.1186/s13102-015-0018-5 · Cited by 360
Children's Pedometer-Determined Physical Activity during the Segmented School Day
TUDOR-LOCKE, C., LEE, S. M., MORGAN, C. F., BEIGHLE, A., & PANGRAZI, R. P. (2006) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000230212.55119.98 · Cited by 284
Metadata
- Authors
- BEETS, M. W., PATTON, M. M., & EDWARDS, S.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 2005-03
- Volume
- 37
- Issue
- 3
- Pages
- 513-520
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W1965683223
- Cited by
- 166
- References
- 27
- FWCI
- 7.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.