The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Predicting Walking METs and Energy Expenditure from Speed or Accelerometry
Abstract
Purpose a) Compare the predictive potential of speed and CSA(hip) (Computer Science Applications accelerometer positioned on the hip) for level terrain walking METs (1 MET = VO2 of 3.5 mL.kg(-1).min(-1)) and energy expenditure (kcal.min(-1)); b) cross-validate previously published CSA(hip)- and speed-based MET and energy expenditure prediction equations; c) measure self-paced walking speed, exercise intensity (METs) and energy expenditure in the middle aged population. Methods Seventy-two 35- to 45-yr-old volunteers walked around a level, paved quadrangle at what they perceived to be a moderate pace. Oxygen consumption was measured using the criterion Douglas bag technique. Speed, CSA(hip), heart rate, and Borg rating of perceived exertion were also monitored. Results Speed explained 10% more variance of walking METs than CSA(hip). Speed and mass explained 8% more variance of walking energy expenditure (kcal.min) than CSA(hip) and mass. The best previously published regression equations predict our walking METs and energy expenditures within 95% prediction limits of +/- 0.7 METs and +/- 1.0 kcal.min(-1), respectively. Women paced themselves at a significantly higher mean speed (5.5 km.h(-1)) and intensity (4.1 METs) than their male counterparts (5.2 km.h(-1) and 3.8 METs). Both genders expended approximately 0.75 kcal.kg(-1) for every kilometer of level terrain walked. Conclusion Speed-based MET and energy expenditure predictions during level terrain walking were more accurat…
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Body-worn accelerometer signals can be correlated with energy expenditure.
“whose signals can be correlated with energy expenditure [e.g., 8–12]”
From Human walking in the real world: interactions between terrain type, gait parameters, and energy expenditure (2021) · cites this paper as [8]
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Age-predicted maximal heart rate revisited
Tanaka, H., Monahan, K. D., & Seals, D. R. (2001) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(00)01054-8 · Cited by 3,775
Obesity and the Environment: Where Do We Go from Here?
Hill, J. O., Wyatt, H. R., Reed, G. W., & Peters, J. C. (2003) · Science · doi:10.1126/science.1079857 · Cited by 2,180
Flagged first, then by citations
Research works printed but not linked: 29
- Balogun, 1989, Human energy expenditure during level walking on a treadmill at speeds of 54–130 m·min−1., Int. Disabil. Stud, 11, 71, 10.3109/03790798909166391 · DOI
- Bassett, 2000, Validity of four motion sensors in measuring moderate intensity physical activity., Med. Sci. Sports Exerc, 32, S471, 10.1097/00005768-200009001-00006 · DOI
- Blessey, 1976, Metabolic energy cost of unrestrained walking., Phys. Ther, 56, 1019, 10.1093/ptj/56.9.1019 · DOI
- Brage, 2003, Reexamination of validity and reliability of the CSA monitor in walking and running., Med. Sci. Sports Exerc, 35, 1447, 10.1249/01.MSS.0000079078.62035.EC · DOI
- Brooks, 2004, Measurement and prediction of METs during household activities in 35–45 yr old females., Eur. J. Appl. Physiol, 91, 638, 10.1007/s00421-003-1018-9 · DOI
- Bubb, 1985, Predicting oxygen uptake during level walking at speeds of 80-130 m/min., J. Card. Rehabil, 5, 462
- Bussmann, 2004, Sensitivity and reproducibility of accelerometry and heart rate in physical strain assessment during prosthetic gait., Eur. J. Appl. Physiol, 91, 71, 10.1007/s00421-003-0916-1 · DOI
- Cunningham, 1982, Determinants of self-selected walking pace across ages 19 to 66., J. Gerontol, 37, 560, 10.1093/geronj/37.5.560 · DOI
- Dobson, 1984, Calculating sample size., Trans. Menzies Found, 7, 75
- Ekelund, 2002, The validity of the Computer Science and Applications activity monitor for use in coronary artery disease patients during level walking., Clin. Physiol. Funct. Imaging, 22, 248, 10.1046/j.1475-097X.2002.00426.x · DOI
- Eston, 1998, Validity of heart rate, pedometry, and accelerometry for predicting the energy cost of children’s activities., J. Appl. Physiol, 84, 362, 10.1152/jappl.1998.84.1.362 · DOI · Paper page
- Fehling, 1999, Comparison of accelerometers with oxygen consumption in older adults during exercise., Med. Sci. Sports Exerc, 31, 171, 10.1097/00005768-199901000-00026 · DOI
- Finley, 1970, Locomotive characteristics of urban pedestrians., Arch. Phys. Med. Rehabil, 51, 423
- Freedson, 1998, Calibration of the Computer Science and Applications, Inc. accelerometer., Med. Sci. Sports Exerc, 30, 777, 10.1097/00005768-199805000-00021 · DOI · Paper page
- Gunn, 2002, Determining energy expenditure during some household and garden tasks., Med. Sci. Sports Exerc, 34, 895, 10.1097/00005768-200205000-00026 · DOI
- Gunn, 2004, Measurement and prediction of energy expenditure in males during household and garden tasks., Eur. J. Appl. Physiol, 91, 61, 10.1007/s00421-003-0932-1 · DOI
- Hendelman, 2000, Validity of accelerometry for the assessment of moderate intensity physical activity in the field., Med. Sci. Sports Exerc, 32, S442, 10.1097/00005768-200009001-00002 · DOI · Paper page
- Leenders, 2003, Ability of different physical activity monitors to detect movement during treadmill walking., Int. J. Sports Med, 24, 43, 10.1055/s-2003-37196 · DOI
- McDonald, 1961, Statistical studies of recorded energy expenditure of man. Part 2: expenditure on walking related to weight, sex, age, height, speed and gradient., Nutr. Abs. Rev, 31, 739
- Melanson, 1995, Validity of the Computer Science and Applications, Inc. (CSA) activity monitor., Med. Sci. Sports Exerc, 27, 934, 10.1249/00005768-199506000-00021 · DOI
- Nichols, 2000, Assessment of physical activity with the Computer Science and Applications, Inc., accelerometer: laboratory versus field validation., Res. Q. Exerc. Sport, 71, 36, 10.1080/02701367.2000.10608878 · DOI
- Passmore, 1955, Human energy expenditure., Physiol. Rev, 35, 801, 10.1152/physrev.1955.35.4.801 · DOI
- Pearce, 1983, Energy cost of treadmill and floor walking at self-selected paces., Eur. J. Appl. Physiol. Occup. Physiol, 52, 115, 10.1007/BF00429037 · DOI
- Swartz, 2000, Estimation of energy expenditure using CSA accelerometers at hip and wrist sites., Med. Sci. Sports Exerc, 32, S450, 10.1097/00005768-200009001-00003 · DOI
- Trost, 1998, Validity of the computer science and applications (CSA) activity monitor in children., Med. Sci. Sports Exerc, 30, 629, 10.1097/00005768-199804000-00023 · DOI
- van der Walt, 1973, An equation for prediction of energy expenditure of walking and running., J. Appl. Physiol, 34, 559, 10.1152/jappl.1973.34.5.559 · DOI · Paper page
- Welk, 2000, A comparative evaluation of three accelerometry-based physical activity monitors., Med. Sci. Sports Exerc, 32, S489, 10.1097/00005768-200009001-00008 · DOI
- Wergel-Kolmert, 1999, Day-to-day variation in oxygen consumption and energy expenditure during submaximal treadmill walking in female adolescents., Clin. Physiol, 19, 161, 10.1046/j.1365-2281.1999.00160.x · DOI
- Yngve, 2003, Effect of monitor placement and of activity setting on the MTI accelerometer output., Med. Sci. Sports Exerc, 35, 320, 10.1249/01.MSS.0000048829.75758.A0 · DOI
Cited by
Sorted by citations
Dowd, K. P., Szeklicki, R., Minetto, M. A., Murphy, M. H., Polito, A., Ghigo, E., van der Ploeg, H., Ekelund, U., Maciaszek, J., Stemplewski, R., et al. (2018) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-017-0636-2 · Cited by 385
Estimating energy expenditure using accelerometers
Crouter, S. E., Churilla, J. R., & Bassett, D. R. (2006) · European Journal of Applied Physiology · doi:10.1007/s00421-006-0307-5 · Cited by 366
Kowalsky, D. B., Rebula, J. R., Ojeda, L. V., Adamczyk, P. G., & Kuo, A. D. (2021) · PLOS One · doi:10.1371/journal.pone.0228682 · Cited by 106
Slootmaker, S. M., Chin A Paw, M. J. M., Schuit, A. J., Van Mechelen, W., & Koppes, L. L. J. (2009) · Scandinavian Journal of Medicine & Science in Sports · doi:10.1111/j.1600-0838.2007.00740.x · Cited by 69
Measuring Moderate-Intensity Exercise with the Apple Watch: Validation Study
Abt, G., Bray, J., & Benson, A. C. (2018) · JMIR Cardio · doi:10.2196/cardio.8574 · Cited by 21
Mobility of paleolithic populations: biomechanical considerations and spatiotemporal modelling
Vaissié, E. (2021) · Paleoanthropology · doi:10.48738/2021.iss1.73 · Cited by 7
Metadata
- Authors
- BROOKS, A. G., GUNN, S. M., WITHERS, R. T., GORE, C. J., & PLUMMER, J. L.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 2005-07
- Volume
- 37
- Issue
- 7
- Pages
- 1216-1223
- ISSN
- 0195-9131
- Cited by
- 73
- References
- 3
- Language
- en
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review