Predicting Walking METs and Energy Expenditure from Speed or Accelerometry

BROOKS, ANTHONY G., GUNN, SIMON M., WITHERS, ROBERT T., GORE, CHRISTOPHER J., PLUMMER, JOHN L.·2005·Medicine & Science in Sports & Exercise

Abstract

Purpose a) Compare the predictive potential of speed and CSA(hip) (Computer Science Applications accelerometer positioned on the hip) for level terrain walking METs (1 MET = VO2 of 3.5 mL.kg(-1).min(-1)) and energy expenditure (kcal.min(-1)); b) cross-validate previously published CSA(hip)- and speed-based MET and energy expenditure prediction equations; c) measure self-paced walking speed, exercise intensity (METs) and energy expenditure in the middle aged population. Methods Seventy-two 35- to 45-yr-old volunteers walked around a level, paved quadrangle at what they perceived to be a moderate pace. Oxygen consumption was measured using the criterion Douglas bag technique. Speed, CSA(hip), heart rate, and Borg rating of perceived exertion were also monitored. Results Speed explained 10% more variance of walking METs than CSA(hip). Speed and mass explained 8% more variance of walking energy expenditure (kcal.min) than CSA(hip) and mass. The best previously published regression equations predict our walking METs and energy expenditures within 95% prediction limits of +/- 0.7 METs and +/- 1.0 kcal.min(-1), respectively. Women paced themselves at a significantly higher mean speed (5.5 km.h(-1)) and intensity (4.1 METs) than their male counterparts (5.2 km.h(-1) and 3.8 METs). Both genders expended approximately 0.75 kcal.kg(-1) for every kilometer of level terrain walked. Conclusion Speed-based MET and energy expenditure predictions during level terrain walking were more accurat…

Overview

Integrity signals

Registry

Crossref · 10.1249/01.mss.0000170074.19649.0e

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Flagged first, then by citations

Research works printed but not linked: 29

  1. Balogun, 1989, Human energy expenditure during level walking on a treadmill at speeds of 54–130 m·min−1., Int. Disabil. Stud, 11, 71, 10.3109/03790798909166391 · DOI
  2. Bassett, 2000, Validity of four motion sensors in measuring moderate intensity physical activity., Med. Sci. Sports Exerc, 32, S471, 10.1097/00005768-200009001-00006 · DOI
  3. Blessey, 1976, Metabolic energy cost of unrestrained walking., Phys. Ther, 56, 1019, 10.1093/ptj/56.9.1019 · DOI
  4. Brage, 2003, Reexamination of validity and reliability of the CSA monitor in walking and running., Med. Sci. Sports Exerc, 35, 1447, 10.1249/01.MSS.0000079078.62035.EC · DOI
  5. Brooks, 2004, Measurement and prediction of METs during household activities in 35–45 yr old females., Eur. J. Appl. Physiol, 91, 638, 10.1007/s00421-003-1018-9 · DOI
  6. Bubb, 1985, Predicting oxygen uptake during level walking at speeds of 80-130 m/min., J. Card. Rehabil, 5, 462
  7. Bussmann, 2004, Sensitivity and reproducibility of accelerometry and heart rate in physical strain assessment during prosthetic gait., Eur. J. Appl. Physiol, 91, 71, 10.1007/s00421-003-0916-1 · DOI
  8. Cunningham, 1982, Determinants of self-selected walking pace across ages 19 to 66., J. Gerontol, 37, 560, 10.1093/geronj/37.5.560 · DOI
  9. Dobson, 1984, Calculating sample size., Trans. Menzies Found, 7, 75
  10. Ekelund, 2002, The validity of the Computer Science and Applications activity monitor for use in coronary artery disease patients during level walking., Clin. Physiol. Funct. Imaging, 22, 248, 10.1046/j.1475-097X.2002.00426.x · DOI
  11. Eston, 1998, Validity of heart rate, pedometry, and accelerometry for predicting the energy cost of children’s activities., J. Appl. Physiol, 84, 362, 10.1152/jappl.1998.84.1.362 · DOI · Paper page
  12. Fehling, 1999, Comparison of accelerometers with oxygen consumption in older adults during exercise., Med. Sci. Sports Exerc, 31, 171, 10.1097/00005768-199901000-00026 · DOI
  13. Finley, 1970, Locomotive characteristics of urban pedestrians., Arch. Phys. Med. Rehabil, 51, 423
  14. Freedson, 1998, Calibration of the Computer Science and Applications, Inc. accelerometer., Med. Sci. Sports Exerc, 30, 777, 10.1097/00005768-199805000-00021 · DOI · Paper page
  15. Gunn, 2002, Determining energy expenditure during some household and garden tasks., Med. Sci. Sports Exerc, 34, 895, 10.1097/00005768-200205000-00026 · DOI
  16. Gunn, 2004, Measurement and prediction of energy expenditure in males during household and garden tasks., Eur. J. Appl. Physiol, 91, 61, 10.1007/s00421-003-0932-1 · DOI
  17. Hendelman, 2000, Validity of accelerometry for the assessment of moderate intensity physical activity in the field., Med. Sci. Sports Exerc, 32, S442, 10.1097/00005768-200009001-00002 · DOI · Paper page
  18. Leenders, 2003, Ability of different physical activity monitors to detect movement during treadmill walking., Int. J. Sports Med, 24, 43, 10.1055/s-2003-37196 · DOI
  19. McDonald, 1961, Statistical studies of recorded energy expenditure of man. Part 2: expenditure on walking related to weight, sex, age, height, speed and gradient., Nutr. Abs. Rev, 31, 739
  20. Melanson, 1995, Validity of the Computer Science and Applications, Inc. (CSA) activity monitor., Med. Sci. Sports Exerc, 27, 934, 10.1249/00005768-199506000-00021 · DOI
  21. Nichols, 2000, Assessment of physical activity with the Computer Science and Applications, Inc., accelerometer: laboratory versus field validation., Res. Q. Exerc. Sport, 71, 36, 10.1080/02701367.2000.10608878 · DOI
  22. Passmore, 1955, Human energy expenditure., Physiol. Rev, 35, 801, 10.1152/physrev.1955.35.4.801 · DOI
  23. Pearce, 1983, Energy cost of treadmill and floor walking at self-selected paces., Eur. J. Appl. Physiol. Occup. Physiol, 52, 115, 10.1007/BF00429037 · DOI
  24. Swartz, 2000, Estimation of energy expenditure using CSA accelerometers at hip and wrist sites., Med. Sci. Sports Exerc, 32, S450, 10.1097/00005768-200009001-00003 · DOI
  25. Trost, 1998, Validity of the computer science and applications (CSA) activity monitor in children., Med. Sci. Sports Exerc, 30, 629, 10.1097/00005768-199804000-00023 · DOI
  26. van der Walt, 1973, An equation for prediction of energy expenditure of walking and running., J. Appl. Physiol, 34, 559, 10.1152/jappl.1973.34.5.559 · DOI · Paper page
  27. Welk, 2000, A comparative evaluation of three accelerometry-based physical activity monitors., Med. Sci. Sports Exerc, 32, S489, 10.1097/00005768-200009001-00008 · DOI
  28. Wergel-Kolmert, 1999, Day-to-day variation in oxygen consumption and energy expenditure during submaximal treadmill walking in female adolescents., Clin. Physiol, 19, 161, 10.1046/j.1365-2281.1999.00160.x · DOI
  29. Yngve, 2003, Effect of monitor placement and of activity setting on the MTI accelerometer output., Med. Sci. Sports Exerc, 35, 320, 10.1249/01.MSS.0000048829.75758.A0 · DOI

Cited by

Sorted by citations

Metadata

Authors
BROOKS, A. G., GUNN, S. M., WITHERS, R. T., GORE, C. J., & PLUMMER, J. L.
Venue
Medicine & Science in Sports & Exercise
Published
2005-07
Volume
37
Issue
7
Pages
1216-1223
ISSN
0195-9131
Cited by
73
References
3
Language
en

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review