The DOI matches its Crossref record; 61 of the 61 references it cites were found in a registry or an index.
The Technology of Accelerometry-Based Activity Monitors: Current and Future
Abstract
PURPOSE: This paper reviews accelerometry-based activity monitors, including single-site first-generation devices, emerging technologies, and analytical approaches to predict energy expenditure, with suggestions for further research and development. METHODS: The physics and measurement principles of the accelerometer are described, including the sensor properties, data collections, filtering, and integration analyses. The paper also compares these properties in several commonly used single-site accelerometers. The emerging accelerometry technologies introduced include the multisensor arrays and the combination of accelerometers with physiological sensors. The outputs of accelerometers are compared with criterion measures of energy expenditure (indirect calorimeters and double-labeled water) to develop mathematical models (linear, nonlinear, and variability approaches). RESULTS: The technologies of the sensor and data processing directly influence the results of the outcome measurement (activity counts and energy expenditure predictions). Multisite assessment and combining accelerometers with physiological measures may offer additional advantages. Nonlinear approaches to predict energy expenditure using accelerometer outputs from multiple sites and orientation can enhance accuracy. CONCLUSIONS: The development of portable accelerometers has made objective assessments of physical activity possible. Future technological improvements will include examining raw acceleration signals and developing advanced models for accurate energy expenditure predictions.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Despite the numerous validation studies already published, the validity of physical activity questionnaires for activity EE estimation remains unclear [63].”
Citations
Cites
Yu, S. M. (1998) · Maternal and Child Health Journal · doi:10.1023/a:1021801927353 · Cited by 3,876
Calibration of the Computer Science and Applications, Inc. accelerometer
FREEDSON, P. S., MELANSON, E., & SIRARD, J. (1998) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199805000-00021 · Cited by 3,825
Medical Instrumentation-Application and Design
Webster, J. G. (1978) · Journal of Clinical Engineering · doi:10.1097/00004669-197807000-00017 · Cited by 1,846
Calibration of Accelerometer Output for Children
Freedson, P. S., POBER, D. M., & Janz, K. F. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185658.28284.ba · Cited by 1,150
Energy expenditure by doubly labeled water: validation in humans and proposed calculation
Schoeller, D. A., Ravussin, É., Schutz, Y., Acheson, K. J., Baertschi, P., & Jéquier, E. (1986) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.1986.250.5.r823 · Cited by 683
Calibration of Accelerometer Output for Adults
MATTHEW, C. E. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185659.11982.3d · Cited by 651
Eston, R. G., Rowlands, A. V., & Ingledew, D. K. (1998) · Journal of Applied Physiology · doi:10.1152/jappl.1998.84.1.362 · Cited by 643
Validity of four motion sensors in measuring moderate intensity physical activity
Bassett, D. R. (2000) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200009001-00006 · Cited by 533
Self-citationValidity of accelerometry for the assessment of moderate intensity physical activity in the field
HENDELMAN, D., MILLER, K., BAGGETT, C., DEBOLD, E., & FREEDSON, P. (2000) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200009001-00002 · Cited by 516
Estimation of energy expenditure using CSA accelerometers at hip and wrist sites
Swartz, A. M., Strath, S. J., Bassett, D. R., BRIEN, W. L. O., King, G. A., & Ainsworth, B. E. (2000) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200009001-00003 · Cited by 514
Self-citationBrage, S., Brage, N., Franks, P. W., Ekelund, U., Wong, M.-Y., Andersen, L. B., Froberg, K., & Wareham, N. J. (2004) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00703.2003 · Cited by 473 · cited 1×
“(3) have demonstrated that the Actiheart-predicted EE, from an accelerometer/HR model, was significantly more accurate than using either parameter alone.”
MethodPrediction of activity energy expenditure using accelerometers in children.
Puyau, M. R., Adolph, A. L., Vohra, F. A., Zakeri, I., & Butte, N. F. (2004) · PubMed · Cited by 472
Assessment of energy expenditure for physical activity using a triaxial accelerometer
Bouten, C. V. C., Westerterp, K. R., Verduin, M., & Janssen, J. J. (1994) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-199412000-00016 · Cited by 451
Physical activity assessed by activity monitor and doubly labeled water in children
Ekelund, U., SJÖSTRÖM, M., Yngve, A., Poortvliet, E., Nilsson, A. E., Froberg, K., Wedderkopp, N., & Westerterp, K. R. (2001) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200102000-00017 · Cited by 441
Validity of the Computer Science and Applications, Inc. (CCA) activity monitor
Melanson, E. L., & Freedson, P. S. (1995) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-199506000-00021 · Cited by 417
Reliability of accelerometry-based activity monitors: a generalizability study.
Welk, G. J., Schaben, J. A., & Morrow, J. R. (2004) · PubMed · Cited by 394
Evaluation of the SenseWear Pro Armband™ to Assess Energy Expenditure during Exercise
Jakicic, J. M., Marcus, M. D., Gallagher, K. I., Randall, C. R., Thomas, E. L., Goss, F. L., & Robertson, R. J. (2004) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000126805.32659.43 · Cited by 362
Reexamination of Validity and Reliability of the CSA Monitor in Walking and Running
Brage, S., Wedderkopp, N., Franks, P. W., Andersen, L. B., & Froberg, K. (2003) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000079078.62035.ec · Cited by 352
A comparative evaluation of three accelerometry-based physical activity monitors
Welk, G. J., Blair, S. N., Wood, K., Jones, S. L., & Thompson, R. W. (2000) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200009001-00008 · Cited by 350
Principles of Design and Analyses for the Calibration of Accelerometry-Based Activity Monitors
Welk, G. J. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185660.38335.de · Cited by 344
Measuring daily behavior using ambulatory accelerometry: The Activity Monitor
Bussmann, J. B. J., Martens, W. L. J., Tulen, J. H. M., Schasfoort, F. C., van den Berg-Emons, R. J. G., & Stam, H. J. (2001) · Behavior Research Methods, Instruments, & Computers · doi:10.3758/bf03195388 · Cited by 315
Measurement of Human Daily Physical Activity
Zhang, K., Werner, P., Sun, M., Pi-Sunyer, X., & Boozer, C. N. (2003) · Obesity Research · doi:10.1038/oby.2003.7 · Cited by 311
Evaluation of heart rate as a method for assessing moderate intensity physical activity
Strath, S. J., Swartz, A. M., Bassett, D. R., BRIEN, W. L. O., King, G. A., & Ainsworth, B. E. (2000) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200009001-00005 · Cited by 302
Self-citationEvaluation of methods to assess physical activity in free-living conditions
Leenders, N., Sherman, W. M., Nagaraja, H. N., & Kien, C. L. (2001) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200107000-00024 · Cited by 255
Estimation of energy expenditure by a portable accelerometer
MONTOYE, H. J., WASHBURN, R., SERVAIS, S., ERTL, A., WEBSTER, J. G., & NAGLE, F. J. (1983) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-198315050-00010 · Cited by 225
Improving energy expenditure estimation by using a triaxial accelerometer
Chen, K. Y., & Sun, M. (1997) · Journal of Applied Physiology · doi:10.1152/jappl.1997.83.6.2112 · Cited by 211
Self-citationOppenheim, A. V. 1., Willsky, A. S., & Nawab, S. H. (1983) · Cited by 209
Motion pattern and posture: Correctly assessed by calibrated accelerometers
Foerster, F., & Fahrenberg, J. (2000) · Behavior Research Methods, Instruments, & Computers · doi:10.3758/bf03200815 · Cited by 188
Improving Energy Expenditure Estimation for Physical Activity
Zhang, K., Pi‐Sunyer, F. X., & Boozer, C. N. (2004) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000126585.40962.22 · Cited by 180
Nichols, J. F., Morgan, C. G., SARKIN, J. A., Sallis, J. F., & Calfas, K. J. (1999) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199906000-00022 · Cited by 178
The accuracy of the TriTrac-R3D accelerometer to estimate energy expenditure
Jakicic, J. M., Winters, C., Lagally, K. M., HO, J., Robertson, R. J., & Wing, R. R. (1999) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199905000-00020 · Cited by 149
Schoeller, D. A., & Hnilicka, J. M. (1996) · PubMed · Cited by 143
Technical reliability of the CSA activity monitor: The EarlyBird Study
Metcalf, B. S., Curnow, J. S. H., EVANS, C. J., Voss, L. D., & Wilkin, T. J. (2002) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200209000-00022 · Cited by 142
Bussmann, H., Reuvekamp, P. J., Veltink, P. H., Martens, W. L. J., & Stam, H. J. (1998) · Physical Therapy · doi:10.1093/ptj/78.9.989 · Cited by 120
Predicting Energy Expenditure of Physical Activity Using Hip- and Wrist-Worn Accelerometers
Chen, K. Y., Acra, S. A., Majchrzak, K. M., Donahue, C. L., Baker, L., Clemens, L. H., Sun, M., & Buchowski, M. S. (2003) · Diabetes Technology & Therapeutics · doi:10.1089/152091503322641088 · Cited by 117
Self-citationAnalysis of instantaneous energy of normal gait
Winter, D. A., Quanbury, A. O., & Reimer, G. D. (1976) · Journal of Biomechanics · doi:10.1016/0021-9290(76)90011-7 · Cited by 115
Comparison of heart rate and physical activity recall with doubly labeled water in obese women
Racette, S. B., Schoeller, D. A., & Kushner, R. F. (1995) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-199501000-00022 · Cited by 115
Technical Variability of the RT3 Accelerometer
Powell, S. M., Jones, D. B., & Rowlands, A. V. (2003) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000089341.68754.ba · Cited by 109
Field evaluation of energy expenditure in women using Tritrac accelerometers
Campbell, K. L., Crocker, P. R. E., & McKenzie, D. C. (2002) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200210000-00020 · Cited by 106
Validation of the Tracmor triaxial accelerometer system for walking
Levine, J. A., Baukol, P., & Westerterp, K. R. (2001) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200109000-00024 · Cited by 102
Measurement of the components of nonexercise activity thermogenesis
Levine, J. A., Melanson, E. L., Westerterp, K. R., & Hill, J. O. (2001) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.2001.281.4.e670 · Cited by 94
Ambulatory monitoring of physical activity in working situations, a validation study
Uiterwaal, M., Glerum, E. B. C., Busser, H. J., & van Lummel, R. C. (1998) · Journal of Medical Engineering & Technology · doi:10.3109/03091909809032535 · Cited by 93
The Use of Uniaxial and Triaxial Accelerometers to Measure Children’s “Free-Play” Physical Activity
Ott, A. E., Pate, R. R., Trost, S. G., Ward, D. S., & Saunders, R. P. (2000) · Pediatric Exercise Science · doi:10.1123/pes.12.4.360 · Cited by 90
VALIDITY OF AMBULATORY ACCELEROMETRY TO QUANTIFY PHYSICAL ACTIVITY IN HEART FAILURE
van den Berg-Emons, R. J. G. (2000) · Scandinavian Journal of Rehabilitation Medicine · doi:10.1080/003655000750060940 · Cited by 87
Comparison of accelerometers with oxygen consumption in older adults during exercise
Fehling, P. C., Smith, D. L., Warner, S., & Dalsky, G. P. (1999) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199901000-00026 · Cited by 85
Livingstone, M. B. E. (1997) · British Journal Of Nutrition · doi:10.1079/bjn19970205 · Cited by 78
Computerized analysis of daily life motor activity for ambulatory monitoring
Kiani, K., Snijders, C. J., & Gelsema, E. S. (1997) · Technology and Health Care · doi:10.3233/thc-1997-5404 · Cited by 77
Louie, L. H.-T., Eston, R. G., Rowlands, A. V., Tong, K. K., Ingledew, D. K., & Fu, F. H. K. (1999) · Pediatric Exercise Science · doi:10.1123/pes.11.3.229 · Cited by 76
Leonard, W. R., Katzmarzyk, P. T., Stephen, M., & Ross, A. G. (1995) · American Journal of Clinical Nutrition · doi:10.1093/ajcn/61.5.1146 · Cited by 71
Bray, M. S., Wong, W. W., Morrow, J. R., Butte, N. F., & Pivarnik, J. M. (1994) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-199412000-00017 · Cited by 70
Moon, J., & Butte, N. F. (1996) · Journal of Applied Physiology · doi:10.1152/jappl.1996.81.4.1754 · Cited by 68
Efficiency of Walking and Stepping: Relationship to Body Fatness
Chen, K. Y., Acra, S. A., Donahue, C. L., Sun, M., & Buchowski, M. S. (2004) · Obesity Research · doi:10.1038/oby.2004.120 · Cited by 54
Self-citationHEART RATE AS AN INDICATOR OF PHYSICAL ACTIVITY INTENSITY IN ADOLESCENTS
Ekelund, U., Poortvliet, E., Yngve, A., Nilsson, A. E., f, A. H.-W., & m, M. S. S. (2001) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200105001-01406 · Cited by 50
Ambulatory monitoring of children's activity
Busser, H. J., Ott, J., van Lummel, R. C., Uiterwaal, M., & Blank, R. (1997) · Medical Engineering & Physics · doi:10.1016/s1350-4533(97)00007-6 · Cited by 47
Analytic Requirements for the Doubly Labeled Water Method
Schoeller, D. A., Taylor, P. B., & Shay, K. (1995) · Obesity Research · doi:10.1002/j.1550-8528.1995.tb00003.x · Cited by 45
Recognition of daily life motor activity classes using an artificial neural network
Kiani, K., Snijders, C. J., & Gelsema, E. S. (1998) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/s0003-9993(98)90291-x · Cited by 43
(1994) · PubMed · Cited by 40
A continuous patient activity monitor: validation and relation to disability
Walker, D., Heslop, P., Plummer, C., Essex, T., & Chandler, S. (1997) · Physiological Measurement · doi:10.1088/0967-3334/18/1/003 · Cited by 32
Effect of physical training on thermogenic responses to cold and ephedrine in obesity.
Nielsen, B., Astrup, A. V., Samuelsen, P., Wengholt, H., & Christensen, N. (1993) · PubMed · Cited by 19
Validity and Reliability of the FitSense FS-1 Speedometer During Walking and Running
Conger, S. A., Strath, S. J., & Bassett, D. R. (2005) · International Journal of Sports Medicine · doi:10.1055/s-2004-820958 · Cited by 3
Self-citationWelk, G. J., Trost, S. G., & Schaben, J. A. (2005) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200505001-00589 · Cited by 1
Cited by
Sorted by citations
Validation of Accelerometer Wear and Nonwear Time Classification Algorithm
CHOI, L., LIU, Z., MATTHEWS, C. E., & BUCHOWSKI, M. S. (2011) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3181ed61a3 · Cited by 1,804
Strath, S. J., Kaminsky, L. A., Ainsworth, B. E., Ekelund, U., Freedson, P. S., Gary, R. A., Richardson, C. R., Smith, D. T., & Swartz, A. M. (2013) · Circulation · doi:10.1161/01.cir.0000435708.67487.da · Cited by 1,029
A Review of Accelerometry-Based Wearable Motion Detectors for Physical Activity Monitoring
Yang, C.-C., & Hsu, Y.-L. (2010) · Sensors · doi:10.3390/s100807772 · Cited by 1,058
Evolution of accelerometer methods for physical activity research
Troiano, R. P., McClain, J. J., Brychta, R. J., & Chen, K. Y. (2014) · British Journal of Sports Medicine · doi:10.1136/bjsports-2014-093546 · Cited by 968
Self-citationAccelerometer Use in Physical Activity: Best Practices and Research Recommendations
WARD, D. S., EVENSON, K. R., VAUGHN, A., RODGERS, A. B., & TROIANO, R. P. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185292.71933.91 · Cited by 779
Metadata
- Authors
- CHEN, K. Y., & BASSETT, D. R.
- Affiliations
- Vanderbilt University (US)
- University of Tennessee at Knoxville (US)
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 2005-11
- Volume
- 37
- Issue
- 11
- Pages
- S490-S500
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2033727719
- Cited by
- 996
- References
- 61
- Citations by year
- 2026: 15 · 2025: 12 · 2024: 38 · 2023: 20 · 2022: 40 · 2021: 37 · 2020: 51 · 2019: 48 · 2018: 42 · 2017: 65 · 2016: 83 · 2015: 57 · 2014: 84 · 2013: 83 · 2012: 82
- FWCI
- 14.78
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Medicine & Science in Sports & Exercise (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institute of Diabetes and Digestive and Kidney Diseases (DK 02973, DK 069465, R01DK069465, DK26557, K25DK002973)
- National Center for Research Resources (RR00095)
- Topics
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Physical Activity and Health
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Obesity, Physical Activity, Diet
- Keywords
- accelerometry, wearable activity trackers, energy expenditure estimation, multi-sensor array, nonlinear prediction model, physical activity measurement, indirect calorimetry
- MeSH terms
- Acceleration, Diffusion of Innovation, Equipment Design, Humans, Locomotion, United States, Ergometry
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review