The DOI matches its Crossref record; 61 of the 61 references it cites were found in a registry or an index.
The Technology of Accelerometry-Based Activity Monitors: Current and Future
Abstract
PURPOSE: This paper reviews accelerometry-based activity monitors, including single-site first-generation devices, emerging technologies, and analytical approaches to predict energy expenditure, with suggestions for further research and development. METHODS: The physics and measurement principles of the accelerometer are described, including the sensor properties, data collections, filtering, and integration analyses. The paper also compares these properties in several commonly used single-site accelerometers. The emerging accelerometry technologies introduced include the multisensor arrays and the combination of accelerometers with physiological sensors. The outputs of accelerometers are compared with criterion measures of energy expenditure (indirect calorimeters and double-labeled water) to develop mathematical models (linear, nonlinear, and variability approaches). RESULTS: The technologies of the sensor and data processing directly influence the results of the outcome measurement (activity counts and energy expenditure predictions). Multisite assessment and combining accelerometers with physiological measures may offer additional advantages. Nonlinear approaches to predict energy expenditure using accelerometer outputs from multiple sites and orientation can enhance accuracy. CONCLUSIONS: The development of portable accelerometers has made objective assessments of physical activity possible. Future technological improvements will include examining raw acceleration signals and developing advanced models for accurate energy expenditure predictions.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Despite the numerous validation studies already published, the validity of physical activity questionnaires for activity EE estimation remains unclear [63].”
Citations
Cites
Yu, S. M. (1998) · Maternal and Child Health Journal · doi:10.1023/a:1021801927353 · Cited by 3,876
Calibration of the Computer Science and Applications, Inc. accelerometer
FREEDSON, P. S., MELANSON, E., & SIRARD, J. (1998) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199805000-00021 · Cited by 3,825
Medical Instrumentation-Application and Design
Webster, J. G. (1978) · Journal of Clinical Engineering · doi:10.1097/00004669-197807000-00017 · Cited by 1,846
Calibration of Accelerometer Output for Children
Freedson, P. S., POBER, D. M., & Janz, K. F. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185658.28284.ba · Cited by 1,150
Energy expenditure by doubly labeled water: validation in humans and proposed calculation
Schoeller, D. A., Ravussin, É., Schutz, Y., Acheson, K. J., Baertschi, P., & Jéquier, E. (1986) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.1986.250.5.r823 · Cited by 683
Calibration of Accelerometer Output for Adults
MATTHEW, C. E. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185659.11982.3d · Cited by 651
Eston, R. G., Rowlands, A. V., & Ingledew, D. K. (1998) · Journal of Applied Physiology · doi:10.1152/jappl.1998.84.1.362 · Cited by 643
Validity of four motion sensors in measuring moderate intensity physical activity
Bassett, D. R. (2000) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200009001-00006 · Cited by 533
Self-citationValidity of accelerometry for the assessment of moderate intensity physical activity in the field
HENDELMAN, D., MILLER, K., BAGGETT, C., DEBOLD, E., & FREEDSON, P. (2000) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200009001-00002 · Cited by 516
Estimation of energy expenditure using CSA accelerometers at hip and wrist sites
Swartz, A. M., Strath, S. J., Bassett, D. R., BRIEN, W. L. O., King, G. A., & Ainsworth, B. E. (2000) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200009001-00003 · Cited by 514
Self-citation
Cited by
Sorted by citations
Validation of Accelerometer Wear and Nonwear Time Classification Algorithm
CHOI, L., LIU, Z., MATTHEWS, C. E., & BUCHOWSKI, M. S. (2011) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3181ed61a3 · Cited by 1,804
Strath, S. J., Kaminsky, L. A., Ainsworth, B. E., Ekelund, U., Freedson, P. S., Gary, R. A., Richardson, C. R., Smith, D. T., & Swartz, A. M. (2013) · Circulation · doi:10.1161/01.cir.0000435708.67487.da · Cited by 1,029
A Review of Accelerometry-Based Wearable Motion Detectors for Physical Activity Monitoring
Yang, C.-C., & Hsu, Y.-L. (2010) · Sensors · doi:10.3390/s100807772 · Cited by 1,058
Evolution of accelerometer methods for physical activity research
Troiano, R. P., McClain, J. J., Brychta, R. J., & Chen, K. Y. (2014) · British Journal of Sports Medicine · doi:10.1136/bjsports-2014-093546 · Cited by 968
Self-citationAccelerometer Use in Physical Activity: Best Practices and Research Recommendations
WARD, D. S., EVENSON, K. R., VAUGHN, A., RODGERS, A. B., & TROIANO, R. P. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185292.71933.91 · Cited by 779
Physical Activity for Health: What Kind? How Much? How Intense? On Top of What?
Powell, K. E., Paluch, A. E., & Blair, S. N. (2011) · Annual Review of Public Health · doi:10.1146/annurev-publhealth-031210-101151 · Cited by 685
Calibration of Accelerometer Output for Adults
MATTHEW, C. E. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185659.11982.3d · Cited by 651
Measurement of Adults' Sedentary Time in Population-Based Studies
Healy, G. N., Clark, B. K., Winkler, E. A. H., Gardiner, P. A., Brown, W. J., & Matthews, C. E. (2011) · American Journal of Preventive Medicine · doi:10.1016/j.amepre.2011.05.005 · Cited by 628
Observing the unwatchable through acceleration logging of animal behavior
Brown, D. D., Kays, R., Wikelski, M. C., Wilson, R. P., & Klimley, A. P. (2013) · Animal Biotelemetry · doi:10.1186/2050-3385-1-20 · Cited by 659
Activity identification using body-mounted sensors—a review of classification techniques
Preece, S. J., Goulermas, J. Y., Kenney, L. P. J., Howard, D., Meijer, K., & Crompton, R. H. (2009) · Physiological Measurement · doi:10.1088/0967-3334/30/4/r01 · Cited by 614
Direct measurement of human movement by accelerometry
Godfrey, A., Conway, R., Meagher, D., & ÓLaighin, G. (2008) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2008.09.005 · Cited by 591
Warren, J. M., Ekelund, U., Besson, H., Mezzani, A., Geladas, N., & Vanhees, L. (2010) · European Journal of Cardiovascular Prevention & Rehabilitation · doi:10.1097/hjr.0b013e32832ed875 · Cited by 587
Assessment of physical activity in youth
Corder, K. L., Ekelund, U., Steele, R. M., Wareham, N. J., & Brage, S. (2008) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00094.2008 · Cited by 582
Assessment of Physical Activity and Energy Expenditure: An Overview of Objective Measures
Hills, A. P., Mokhtar, N., & Byrne, N. M. (2014) · Frontiers in Nutrition · doi:10.3389/fnut.2014.00005 · Cited by 649
Wearable and implantable wireless sensor network solutions for healthcare monitoring
Darwish, A., & Hassanien, A. E. (2011) · Sensors · doi:10.3390/s110605561 · Cited by 556
Hurling, R., Catt, M., De Boni, M., Fairley, B. W., Hurst, T., Murray, P., Richardson, A., & Sodhi, J. S. (2007) · Journal of Medical Internet Research · doi:10.2196/jmir.9.2.e7 · Cited by 536
Methods of Measurement in epidemiology: Sedentary Behaviour
Atkin, A. J., Gorely, T., Clemes, S. A., Yates, T., Edwardson, C., Brage, S., Salmon, J., Marshall, S. J., & Biddle, S. J. (2012) · International Journal of Epidemiology · doi:10.1093/ije/dys118 · Cited by 518
Nathan, R., Spiegel, O., Fortmann‐Roe, S., Harel, R., Wikelski, M. C., & Getz, W. M. (2012) · Journal of Experimental Biology · doi:10.1242/jeb.058602 · Cited by 522
Practical Guide to Measuring Physical Activity
Sylvia, L. G., Bernstein, E. E., Hubbard, J. L., Keating, L., & Anderson, E. J. (2014) · Journal of the Academy of Nutrition and Dietetics · doi:10.1016/j.jand.2013.09.018 · Cited by 637
Vanrenterghem, J., Nedergaard, N. J., Robinson, M. A., & Drust, B. (2017) · Sports Medicine · doi:10.1007/s40279-017-0714-2 · Cited by 478
How many days of monitoring predict physical activity and sedentary behaviour in older adults?
Hart, T. L., Swartz, A. M., Cashin, S. E., & Strath, S. J. (2011) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/1479-5868-8-62 · Cited by 469
Cliff, D. P., Reilly, J. J., & Okely, A. D. (2009) · Journal of science and medicine in sport · doi:10.1016/j.jsams.2008.10.008 · Cited by 469
Ohkawara, K., Oshima, Y., Hikihara, Y., Ishikawa‐Takata, K., Tabata, I., & Tanaka, S. (2011) · British Journal Of Nutrition · doi:10.1017/s0007114510005441 · Cited by 463
Smart wearable body sensors for patient self-assessment and monitoring
Appelboom, G., Camacho, E., Abraham, M. E., Bruce, S. S., Dumont, E. L., Zacharia, B. E., D’Amico, R. S., Slomian, J., Reginster, J., Bruyère, O., et al. (2014) · Archives of Public Health · doi:10.1186/2049-3258-72-28 · Cited by 445
State of the Art Reviews: Measurement of Physical Activity in Children and Adolescents
Trost, S. G. (2007) · American Journal of Lifestyle Medicine · doi:10.1177/1559827607301686 · Cited by 405
Dowd, K. P., Szeklicki, R., Minetto, M. A., Murphy, M. H., Polito, A., Ghigo, E., van der Ploeg, H., Ekelund, U., Maciaszek, J., Stemplewski, R., et al. (2018) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-017-0636-2 · Cited by 385
Lang, C. E., Bland, M. D., Bailey, R. R., Schaefer, S. Y., & Birkenmeier, R. L. (2012) · Journal of Hand Therapy · doi:10.1016/j.jht.2012.06.005 · Cited by 388
Actigraph GT3X: Validation and Determination of Physical Activity Intensity Cut Points
Santos‐Lozano, A., Santín-Medeiros, F., Cardon, G., Torres‐Luque, G., Bailón, R., Bergmeir, C., Ruiz, J. R., Lucía, A., & Garatachea, N. (2013) · International Journal of Sports Medicine · doi:10.1055/s-0033-1337945 · Cited by 388
Assessing Physical Activity Using Wearable Monitors: Measures of Physical Activity
BUTTE, N. F., EKELUND, U., & WESTERTERP, K. R. (2012) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3182399c0e · Cited by 359
Accelerometers and pedometers: methodology and clinical application
Corder, K., Brage, S., & Ekelund, U. (2007) · Current Opinion in Clinical Nutrition and Metabolic Care · doi:10.1097/mco.0b013e328285d883 · Cited by 339
Gorman, E., Hanson, H. M., Yang, P. H., Khan, K., Liu-Ambrose, T. Y. L., & Ashe, M. C. (2013) · European Review of Aging and Physical Activity · doi:10.1007/s11556-013-0132-x · Cited by 362
Murphy, S. L. (2008) · Preventive Medicine · doi:10.1016/j.ypmed.2008.12.001 · Cited by 326
Porciuncula, F., Cataldo, A. V. R., Kumar, D., Davis, I. S., Roy, S. H., Walsh, C. J., & Awad, L. N. (2018) · PM&R · doi:10.1016/j.pmrj.2018.06.013 · Cited by 309
Wear Compliance and Activity in Children Wearing Wrist- and Hip-Mounted Accelerometers
Fairclough, S. J., Noonan, R. J., Rowlands, A. V., van Hees, V. T., Knowles, Z. R., & Boddy, L. M. (2015) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000771 · Cited by 316
Monitoring of Physical Activity after Stroke: A Systematic Review of Accelerometry-Based Measures
Gebruers, N., Vanroy, C., Truijen, S., Engelborghs, S., & De Deyn, P. P. (2010) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2009.10.025 · Cited by 293
Calibration and Validation of Wearable Monitors
BASSETT, D. R., Rowlands, A. V., & Trost, S. G. (2011) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3182399cf7 · Cited by 293
Self-citationvan Hees, V. T., Renström, F., Wright, A., Gradmark, A., Catt, M., Chen, K. Y., Löf, M., Bluck, L. J. C., Pomeroy, J. J., Wareham, N. J., et al. (2011) · PLoS ONE · doi:10.1371/journal.pone.0022922 · Cited by 307
Self-citationChandler, J., Brazendale, K., Beets, M. W., & Mealing, B. A. (2015) · Pediatric Obesity · doi:10.1111/ijpo.12033 · Cited by 296
The Effect of Laparoscopic Versus Open Ovariectomy on Postsurgical Activity in Small Dogs
Culp, W. T. N., Mayhew, P. D., & Brown, D. C. (2009) · Veterinary Surgery · doi:10.1111/j.1532-950x.2009.00572.x · Cited by 272
Hagströmer, M., Troiano, R. P., Sjöstróm, M., & Berrigan, D. A. (2010) · American Journal of Epidemiology · doi:10.1093/aje/kwq069 · Cited by 268
Diosdado, J. A. V., Barker, Z. E., Hodges, H. R., Amory, J., Croft, D. P., Bell, N. J., & Codling, E. A. (2015) · Animal Biotelemetry · doi:10.1186/s40317-015-0045-8 · Cited by 272
on behalf of the ToyBox-study group, Craemer, M. D., Decker, E. D., Verloigne, M., Bourdeaudhuij, I. D., Μanios, Y., & Cardon, G. (2016) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-015-0325-y · Cited by 260
Comparison of three generations of ActiGraph™ activity monitors in children and adolescents
Robusto, K. M., & Trost, S. G. (2012) · Journal of Sports Sciences · doi:10.1080/02640414.2012.710761 · Cited by 254
Evaluation of three-dimensional accelerometers to monitor and classify behavior patterns in cattle
Robért, B., White, B. J., Renter, D. G., & Larson, R. L. (2009) · Computers and Electronics in Agriculture · doi:10.1016/j.compag.2009.03.002 · Cited by 250
Technical Reliability Assessment of Three Accelerometer Models in a Mechanical Setup
Esliger, D., & Tremblay, M. S. (2006) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000239394.55461.08 · Cited by 244
Ancillao, A., Tedesco, S. A., Barton, J. J., & O’Flynn, B. (2018) · Sensors · doi:10.3390/s18082564 · Cited by 244
Monitoring of Posture Allocations and Activities by a Shoe-Based Wearable Sensor
Sazonov, E. E., Fulk, G. D., Hill, J. O., Schütz, Y., & Browning, R. C. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2046738 · Cited by 237
Physical Activity Classification Using the GENEA Wrist-Worn Accelerometer
ZHANG, S., ROWLANDS, A. V., MURRAY, P., & HURST, T. L. (2012) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31823bf95c · Cited by 233
Moving beyond Karnofsky and ECOG Performance Status Assessments with New Technologies
Kelly, C. M., & Shahrokni, A. (2016) · Journal of Oncology · doi:10.1155/2016/6186543 · Cited by 229
de Zambotti, M., Baker, F. C., Willoughby, A. R., Godino, J. G., Wing, D., Patrick, K., & Colrain, I. M. (2016) · Physiology & Behavior · doi:10.1016/j.physbeh.2016.03.006 · Cited by 222
Continuous Monitoring of Vital Signs Using Wearable Devices on the General Ward: Pilot Study
Weenk, M., van Goor, H., Frietman, B., Engelen, L. J., van Laarhoven, C. J. H. M., Smit, J. W. A., Bredie, S. J. H., & van de Belt, T. H. (2017) · JMIR mhealth and uhealth · doi:10.2196/mhealth.7208 · Cited by 233
Kelly, L. A., McMillan, D. G., Anderson, A., Fippinger, M., Fillerup, G., & Rider, J. H. (2013) · BMC Medical Physics · doi:10.1186/1756-6649-13-5 · Cited by 220
Schrack, J. A., Cooper, R., Koster, A., Shiroma, E. J., Murabito, J. M., Rejeski, W. J., Ferrucci, L., & Harris, T. B. (2016) · The Journals of Gerontology Series A · doi:10.1093/gerona/glw026 · Cited by 242
Validity of Consumer-Based Physical Activity Monitors for Specific Activity Types
Nelson, M. B., Kaminsky, L. A., Dickin, D. C., & Montoye, A. H. K. (2016) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000933 · Cited by 206
Calibration of ActiGraph GT3X, Actical and RT3 accelerometers in adolescents
Romanzini, M., Petróski, E. L., Ohara, D., Dourado, A. C., & Reichert, F. F. (2012) · European Journal of Sport Science · doi:10.1080/17461391.2012.732614 · Cited by 218
Cust, A. E., Smith, B. J., Chau, J. Y., van der Ploeg, H. P., Friedenreich, C. M., Armstrong, B. K., & Bauman, A. E. (2008) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/1479-5868-5-33 · Cited by 200
Self-contained Position Tracking of Human Movement Using Small Inertial/Magnetic Sensor Modules
Yun, X., Bachmann, E. R., Moore, H. E., & Calusdian, J. (2007) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.2007.363845 · Cited by 194
Kim, Y., Beets, M. W., & Welk, G. J. (2012) · Journal of science and medicine in sport · doi:10.1016/j.jsams.2011.12.001 · Cited by 187
Accuracy of 2 Activity Monitors in Detecting Steps in People With Stroke and Traumatic Brain Injury
Fulk, G. D., Combs, S. A., Danks, K. A., Nirider, C. D., Raja, B., & Reisman, D. S. (2014) · Physical Therapy · doi:10.2522/ptj.20120525 · Cited by 182
Comparison of Four ActiGraph Accelerometers during Walking and Running
John, D., Tyo, B. M., & Bassett, D. R. (2010) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3181b3af49 · Cited by 183
Self-citationGyllensten, I. C., & Bonomi, A. G. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2160723 · Cited by 183
Technical variability of the GT3X accelerometer
Santos‐Lozano, A., Marin, P. J., Torres‐Luque, G., Ruiz, J. R., Lucía, A., & Garatachea, N. (2012) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2012.02.005 · Cited by 181
Arnardóttir, N. Ý., Koster, A., Domelen, D. R. V., Brychta, R. J., Caserotti, P., Eiríksdóttir, G., Sverrisdottir, J. E., Launer, L. J., Gudnason, V. G., Jóhannsson, E., et al. (2012) · Age and Ageing · doi:10.1093/ageing/afs160 · Cited by 179
Self-citationCategorising sheep activity using a tri-axial accelerometer
Barwick, J., Lamb, D. W., Dobos, R. C., Welch, M., & Trotter, M. G. (2018) · Computers and Electronics in Agriculture · doi:10.1016/j.compag.2018.01.007 · Cited by 177
Patterns of adult stepping cadence in the 2005–2006 NHANES
Tudor-Locke, C. E., Camhi, S. M., Leonardi, C., Johnson, W. D., Katzmarzyk, P. T., Earnest, C. P., & Church, T. S. (2011) · Preventive Medicine · doi:10.1016/j.ypmed.2011.06.004 · Cited by 173
Validity of Physical Activity Intensity Predictions by ActiGraph, Actical, and RT3 Accelerometers
Rothney, M. P., Schaefer, E. V., Neumann, M. M., Choi, L., & Chen, K. Y. (2008) · Obesity · doi:10.1038/oby.2008.279 · Cited by 175
Self-citationTeixeira, E., Fonseca, H., Diniz‐Sousa, F., Veras, L., Boppre, G., de Oliveira, J. J. F., Pinto, D., Alves, A. J., Barbosa, A., Mendes, R., et al. (2021) · Geriatrics · doi:10.3390/geriatrics6020038 · Cited by 179
Bidder, O. R., Campbell, H. A., Gómez‐Laich, A., Urgé, P., Walker, J., Cai, Y., Gao, L., Quintana, F., & Wilson, R. P. (2014) · PLoS ONE · doi:10.1371/journal.pone.0088609 · Cited by 170
Inertial Sensor Technology for Elite Swimming Performance Analysis: A Systematic Review
Mooney, R., Corley, G. J., Godfrey, A., Quinlan, L. R., & OLaighin, G. M. (2015) · Sensors · doi:10.3390/s16010018 · Cited by 168
Cain, K. L., Conway, T. L., Adams, M. A., Husak, L. E., & Sallis, J. F. (2013) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/1479-5868-10-51 · Cited by 165
Validation of Sleep-Tracking Technology Compared with Polysomnography in Adolescents.
de Zambotti, M., Baker, F., & Colrain, I. (2015) · Sleep · doi:10.5665/sleep.4990 · Cited by 158
Comparison of the IPAQ-Short Form and Accelerometry Predictions of Physical Activity in Older Adults
Grimm, E. K., Swartz, A. M., Hart, T. L., Miller, N. E., & Strath, S. J. (2012) · Journal of Aging and Physical Activity · doi:10.1123/japa.20.1.64 · Cited by 158
The Measurement and Interpretation of Children's Physical Activity.
Rowlands, A. V., & Eston, R. G. (2007) · Europe PMC (PubMed Central) · Cited by 153
Validation of Biofeedback Wearables for Photoplethysmographic Heart Rate Tracking.
(2016) · PubMed Central · Cited by 150
Accelerometer counts and raw acceleration output in relation to mechanical loading
Rowlands, A. V., & Stiles, V. H. (2012) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2011.12.006 · Cited by 161
Wallén, M. B., Franzén, E., Nero, H., & Hagströmer, M. (2015) · Physical Therapy · doi:10.2522/ptj.20140374 · Cited by 149
Wang, Z., Jiang, M., Hu, Y., & Li, H. (2012) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2012.2196440 · Cited by 146
Scheers, T., Philippaerts, R. M., & Lefevre, J. (2011) · European Journal of Applied Physiology · doi:10.1007/s00421-011-2131-9 · Cited by 153
Loprinzi, P. D. (2013) · Aging & Mental Health · doi:10.1080/13607863.2013.801066 · Cited by 142
Bullitt, E., Rahman, F. N., Smith, J. K., Kim, E., Zeng, D., Katz, L. M., & Marks, B. L. (2009) · American Journal of Neuroradiology · doi:10.3174/ajnr.a1695 · Cited by 142
van Lummel, R. C., Walgaard, S., Pijnappels, M. A. G. M., Elders, P. J. M., García‐Aymerich, J., van Dieën, J. H., & Beek, P. J. (2015) · PLoS ONE · doi:10.1371/journal.pone.0144048 · Cited by 155
Validation of photoplethysmography as a method to detect heart rate during rest and exercise
Spierer, D. K., Rosen, Z., Litman, L. L., & Fujii, K. (2015) · Journal of Medical Engineering & Technology · doi:10.3109/03091902.2015.1047536 · Cited by 139
Monitoring human health behaviour in one's living environment: A technological review
Lowe, S., & OLaighin, G. M. (2013) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2013.11.010 · Cited by 147
Mendelson, M., Bailly, S., Marillier, M., Flore, P., Borel, J. C., Vivodtzev, I., Doutreleau, S., Verges, S., Tamisier, R., & Pépin, J.-L. (2018) · Frontiers in Neurology · doi:10.3389/fneur.2018.00073 · Cited by 134
“Therefore, these data are not always comparable between devices (55).”
BackgroundCorrelates of physical activity among individuals with multiple sclerosis
Motl, R. W., Snook, E. M., McAuley, E., Scott, J. A., & Douglass, M. L. (2006) · Annals of Behavioral Medicine · doi:10.1207/s15324796abm3202_13 · Cited by 134
METs and Accelerometry of Walking in Older Adults
Hall, K. S. M., Howe, C. A., Rana, S. R., MARTIN, C. L., & Morey, M. C. (2013) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e318276c73c · Cited by 134
DTN routing in body sensor networks with dynamic postural partitioning
Quwaider, M., & Biswas, S. K. (2010) · Ad Hoc Networks · doi:10.1016/j.adhoc.2010.03.002 · Cited by 132
Manns, P. J., Dunstan, D. W., Owen, N. G., & Healy, G. N. (2011) · Physical Therapy · doi:10.2522/ptj.20110284 · Cited by 136
Medina, C., Barquera, S., & Janssen, I. (2013) · PubMed · Cited by 130
Ability of Thigh-Worn ActiGraph and activPAL Monitors to Classify Posture and Motion
Steeves, J. A., Bowles, H. R., McClain, J. J., Dodd, K. W., Brychta, R. J., WANG, J., & Chen, K. Y. (2014) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000497 · Cited by 136
Self-citationIntegration of physiological and accelerometer data to improve physical activity assessment
STRATH, S. J., BRAGE, S., & EKELUND, U. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185650.68232.3f · Cited by 126
Influence of disease activity on the physical activity of rheumatoid arthritis patients
Hernández-Hernández, V., Ferraz‐Amaro, I., & Díaz‐González, F. (2013) · Lara D. Veeken · doi:10.1093/rheumatology/ket422 · Cited by 128
Gait analysis – Available platforms for outcome assessment
Klöpfer-Krämer, I. T., Brand, A., Wackerle, H., Müßig, J. A., Kröger, I., & Augat, P. (2019) · Injury · doi:10.1016/j.injury.2019.11.011 · Cited by 128
Symptoms, self-efficacy, and physical activity among individuals with multiple sclerosis
Motl, R. W., Snook, E. M., McAuley, E., & Gliottoni, R. C. (2006) · Research in Nursing & Health · doi:10.1002/nur.20161 · Cited by 124
Behaviour classification of extensively grazed sheep using machine learning
Fogarty, E. S., Swain, D. L., Cronin, G. M., Moraes, L. E., & Trotter, M. G. (2019) · Computers and Electronics in Agriculture · doi:10.1016/j.compag.2019.105175 · Cited by 124
Age-Related Change in Physical Activity in Adolescent Girls
Pate, R. R., Stevens, J., Webber, L. S., Dowda, M. C., Murray, D. M., Young, D. R., & Going, S. B. (2008) · Journal of Adolescent Health · doi:10.1016/j.jadohealth.2008.07.003 · Cited by 122
Loprinzi, P. D., Lee, H. J., & Cardinal, B. J. (2014) · American Journal of Health Promotion · doi:10.4278/ajhp.130709-quan-354 · Cited by 126
Heart rate variability related to effort at work
Uusitalo, A. L. T., Mets, T., Martinmäki, K., Mauno, S., Kinnunen, U. M., & Rusko, H. K. (2011) · Applied Ergonomics · doi:10.1016/j.apergo.2011.01.005 · Cited by 132
Jeong, H., Lee, J. Y., Lee, K., Kang, Y. J., Kim, J.-T., Avila, R., Tzavelis, A., Kim, J., Ryu, H., Kwak, S. S., et al. (2021) · Science Advances · doi:10.1126/sciadv.abg3092 · Cited by 121
Hale, L. A., Pal, J., & Becker, I. (2008) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2008.02.027 · Cited by 118
Metadata
- Authors
- CHEN, K. Y., & BASSETT, D. R.
- Affiliations
- Vanderbilt University (US)
- University of Tennessee at Knoxville (US)
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 2005-11
- Volume
- 37
- Issue
- 11
- Pages
- S490-S500
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2033727719
- Cited by
- 996
- References
- 61
- Citations by year
- 2026: 15 · 2025: 12 · 2024: 38 · 2023: 20 · 2022: 40 · 2021: 37 · 2020: 51 · 2019: 48 · 2018: 42 · 2017: 65 · 2016: 83 · 2015: 57 · 2014: 84 · 2013: 83 · 2012: 82
- FWCI
- 14.78
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Medicine & Science in Sports & Exercise (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institute of Diabetes and Digestive and Kidney Diseases (DK 02973, DK 069465, R01DK069465, DK26557, K25DK002973)
- National Center for Research Resources (RR00095)
- Topics
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Physical Activity and Health
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Obesity, Physical Activity, Diet
- Keywords
- accelerometry, wearable activity trackers, energy expenditure estimation, multi-sensor array, nonlinear prediction model, physical activity measurement, indirect calorimetry
- MeSH terms
- Acceleration, Diffusion of Innovation, Equipment Design, Humans, Locomotion, United States, Ergometry
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review